Percutaneous balloon pericardiotomy as a therapeutic alternative for cardiac tamponade and recurrent pericardial effusion.

A terminally ill patient with cardiac tamponade secondary to metastatic breast cancer was successfully treated by percutaneous balloon pericardiotomy. The procedure was performed through subxiphoid approach under local anaesthesia and its beneficial effect was maintained until the patient's death from her primary disease. A second, 86-year-old, debilitated patient and a third 52-year-old patient were managed likewise and both left hospital relieved from recurrent severe pericardial effusions. The later two patients have shown no signs of recurrence for fifteen and twelve months respectively.

Aged↗

Acute biological response to laser balloon angioplasty in the atherosclerotic rabbit.

Laser balloon angioplasty with Nd:YAG energy has been proposed as a method to seal intimal dissection and prevent elastic recoil after balloon angioplasty. To better define the vessel response to laser balloon angioplasty, its effects on luminal diameter, Indium-111 labelled platelet deposition, and histology were studied in 10 atherosclerotic rabbits. Balloon angioplasty was performed in both iliac arteries and was followed by laser balloon angioplasty in only one iliac artery. The nonlased artery served as a control. Single (15-35 W for 20 sec) or repetitive laser pulses (12-25 W for 20 sec x 3) were used. Platelet deposition was quantified 2 hr after the intervention. Lumen diameter (mm) increased following balloon angioplasty from 0.99 +/- 0.47 (mean +/- SD) to 1.92 +/- 0.43 and 0.89 +/- 0.46 to 1.99 +/- 0.57 in the balloon and laser-treated arteries, respectively (P < 0.001 for both groups for comparisons to baseline, P = NS for between groups comparison). Laser balloon angioplasty resulted in a further increase in luminal diameter to 2.42 +/- 0.53 (P < 0.02) when compared to the post balloon angioplasty diameter. Platelet deposition (10(6)/cm vessel) was higher following laser balloon angioplasty (26.9, 10.2-189; median range) than after balloon angioplasty (10.6, 3.4-30), P < 0.001. Histologic evidence of laser "sealing" was present in only one artery. Thus although laser balloon angioplasty results in an improved lumen diameter, it is accompanied by increased platelet deposition. In the atherosclerotic rabbit model, abolition of vascular recoil rather than "sealing" seems to be the most important advantage of laser balloon angioplasty over conventional balloon angioplasty.

Angiography↗

Hyperinsulinaemia in syndrome X: a marker of the syndrome?

BACKGROUND: Stimulated hyperinsulinaemia is observed in some patients with syndrome X, defined as angina, positive stress test and normal coronary arteriography, and may be involved in the pathogenesis of the syndrome. An increased sympathetic response to exercise may also be pathogenetically involved. However, the diagnostic value of hyperinsulinaemia as a marker of this syndrome has not been defined. METHODS: We determined blood glucose and immunoreactive insulin during fasting, at 60 and 120 min after a glucose load of 75g in 21 patients (eight men, 13 women, 53.9 +/- 7.1 years old) with syndrome X and in 21 healthy volunteers matched to the patients for age, sex and body mass index (eight men, 13 women, 51.6 +/- 9.3 years old). Insulin values were related to the rate-pressure product increase at first exercise stage. RESULTS: The glucose values as well as the insulin values during fasting were similar in syndrome X patients and in controls. However, significantly higher insulin values (mU/l) were observed at 60 (P < 0.01) and 120 min (P < 0.005) in syndrome X patients (median 75.5 and 52, range 43-290 and 6.1-212, respectively) than in controls (median 47.5 and 24.5, range 8-195.6 and 5.2-164, respectively). A considerable overlap of insulin values, however, was observed between the two groups, with abnormal values even during fasting. For a specificity of 95%, an abnormal insulin value had a sensitivity of between 19 and 24% and a diagnostic accuracy of 57-60%. A significant positive correlation was found between insulin levels after the glucose load and the rate-pressure product increment with exercise (60 min, r = 0.60; 120 min, r = 0.65). CONCLUSION: Hyperinsulinaemia may be pathogenetically involved in syndrome X patients, in close relation to the higher sympathetic drive that characterizes this syndrome. However, the wide range of insulin values, frequently overlapping with normal values, limits the usefulness of this abnormality as a marker of the syndrome.

Blood Glucose↗

Intracoronary Palmaz-Schatz stent placement after complicated angioplasty: medium term follow-up.

Acute or impending coronary artery occlusion during percutaneous coronary balloon angioplasty represents a serious and potentially life-threatening complication. We studied the clinical and angiographic outcome in 21 patients who underwent emergent intracoronary Palmaz-Schatz stent implantation (11 due to persistent residual stenosis and 10 due to flow-limiting dissection) during complicated balloon angioplasty and who were followed for a mean period of 7.9 +/- 5.7 months. Excluding one patient lost to follow-up, the event-free survival rate was 70%. Six (30%) patients developed adverse clinical events. One died and 3 required elective revascularization procedures. One subacute stent thrombosis was documented. Acute Q-wave myocardial infarction occurred in 2 patients. Among 9 patients studied angiographically 5.6 +/- 2.5 months after stent placement, 2 had developed restenosis (> 50% luminal narrowing). Eleven have remained essentially symptom free. For selected patients, emergent deployment of a Palmaz-Schatz coronary stent, following complicated balloon angioplasty, offers satisfactory long-term results, thus obviating the need for a high risk emergency bypass surgery.

Angioplasty, Balloon, Coronary↗

Angina and coronary artery disease in patients with aortic valve disease.

The significance of angina pectoris in patients with aortic valve disease (AVD) and the need for coronary arteriography before valve replacement are controversial. The history of chest pain and coronary arteriographic findings were reviewed in 333 patients > or = forty years old, with AVD: 142 with aortic stenosis, 87 with mixed AVD and 104 with aortic regurgitation. The prevalence of coronary artery disease (CAD) was similar among different types of AVD. Angina pectoris was more frequent in patients with aortic stenosis (56%) and mixed AVD (53%) than in patients with aortic regurgitation (24%) (p < 0.0001). Similar results were found in patients with and without CAD. Twenty-six of 95 (27%) patients with CAD had no chest pain at all. The absence of any chest pain in CAD patients was more frequent in those > or = sixty years old than in those < sixty (p < 0.05). Thus, since a significant number of patients had CAD in the absence of any chest pain, the authors recommend coronary arteriography for all patients > or = forty years of age before aortic valve replacement.

Aged↗

Thrombosis-related markers in unstable angina pectoris.

While thrombus formation has been implicated in the pathogenesis of unstable angina, the value of thrombus-related markers for distinguishing unstable from stable angina is not well defined. Fibrin D-dimer and plasminogen activator inhibitor were prospectively analyzed in the peripheral blood of 46 patients (26 with unstable angina and 20 with stable angina or normal coronary arteries). Baseline blood samples were drawn within 24 h after rest pain in patients with unstable angina and in 19 of these 26 patients in less than 6 h. In patients with unstable angina, mean +/- SD (median) values for fibrin D-dimer and plasminogen activator inhibitor values measured 0.09 +/- 0.06 (0.07) microgram/ml and 9.1 +/- 9.6 (5.9) IU, respectively, compared to 0.11 +/- 0.10 (0.05) microgram/ml and 5.5 +/- 1.9 (5.0) IU/ml, in patients in the control group (p = NS for all comparisons between the two groups). Recurrent in-hospital pain, coronary anatomy and need for intervention showed no relation to the levels of these markers. In 19 additional patients (9 with unstable angina and 10 control patients) samples from the coronary sinus and the peripheral blood were also analyzed. Again, in patients with unstable angina all samples were drawn less than 24 h after rest pain; in six of nine patients samples were drawn in less than 6 h. A coronary sinus to peripheral blood gradient for either of these markers could not be demonstrated. The differences between peripheral and coronary sinus D-dimer and plasminogen activator inhibitor concentrations were also similar in patients with unstable angina and control patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Coronary laser thermal angioplasty in the swine: reduced complications with shorter laser delivery time.

Although laser thermal angioplasty (LTA) with a laser heated metal probe has been tolerated in diseased human coronary arteries, definition of a safety threshold is lacking. Determination of safer operation parameters for coronary LTA using a new "over the wire" 1.3-mm laser probe catheter was attempted in seven normal pigs in which platelets were labeled with indium-111. Argon laser power of 10 watts was used for 1, 2, 3, and 5 seconds. Macroscopic findings, platelet deposition and histologic changes were compared between the laser treated coronary segments and controls, the nonheated laser probe, and the wire alone segments. After 1-second LTA, there was no vessel perforation or occlusive thrombi and only infrequent nonocclusive thrombi; platelet deposition was minimal; and histologic alterations rare and superficial. These findings were comparable to controls, the nonheated laser probe, and the wire alone segments. In contrast, vessels treated for 2, 3, and 5 seconds had more frequent perforation, and occlusive and nonocclusive thrombi that was accompanied by platelet deposition significantly greater than vessels treated with LTA for 1 second. A deep histologic injury was present in most of these segments. Additionally, the safety of laser delivery of 1 second repeated for five times was tested in two additional pigs. On macroscopic and histologic analysis the incidence of vessel perforation, occlusive and nonocclusive thrombi appeared slightly less when compared to the 2-, 3-, and 5-second LTA groups, and more than the 1-second LTA group.(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Laser↗

Holter monitoring of ventricular arrhythmias in a randomised, controlled study of intravenous streptokinase in acute myocardial infarction.

The occurrence of ventricular arrhythmias attributed to streptokinase treatment in acute myocardial infarction is not well defined. Holter monitoring was performed for 24 hours in 81 patients with suspected acute myocardial infarction randomised in a ratio of 2:1 to intravenous streptokinase 1.5 x 10(6) IU (n = 55) or placebo infusion (n = 26) 6.7 hours (mean) after the onset of symptoms. No episodes of ventricular fibrillation were recorded. For the whole 24 hour period and during the first three hours after the start of treatment the incidence and frequency of ventricular arrhythmias were similar in the patients randomised to streptokinase and to placebo. But when the results in patients randomised "early" after the onset of symptoms of suspected acute myocardial infarction were analysed separately the frequency of abnormal complexes, pairs, runs, and repetitive arrhythmias seemed to be higher in patients allocated to streptokinase. This may reflect arrhythmias associated with reperfusion.

Arrhythmias, Cardiac↗

Angiographic patterns of balloon inflation during percutaneous transluminal coronary angioplasty: role of pressure-diameter curves in studying distensibility and elasticity of the stenotic lesion and the mechanism of dilation.

There are few in vivo data concerning the mechanisms of balloon inflation during coronary angioplasty. To characterize how lesions dilate, videodensitometry was used to measure the diameter of the inflated balloon across 29 coronary lesions in 27 patients. Pressure-diameter curves for each lesion were derived with use of a standardized incremental inflation protocol in which pressures between 2 and 6 atm in 3 mm low profile balloons approximated normal vessel diameter. The diameter of coronary stenosis before and after angioplasty was also measured. Pressure-diameter curves showed that the most improvement in luminal caliber occurred at low inflation pressure. A distensibility factor was defined as the ratio of the amount of balloon inflation at 2 atm compared with the balloon diameter at 6 atm. Eccentric irregular lesions (n = 11) had a greater distensibility factor (0.49 +/- 0.17) than did lesions (n = 18) without this configuration (0.33 +/- 0.14) (p less than 0.02). The former were soft, presumably because of thrombus in these lesions. In addition, there were no differences in patterns of balloon inflation for lesions requiring additional inflation or for dilations resulting in an intimal crack or dissection after angioplasty. There was often a loss of luminal caliber when balloon diameter at 6 atm was compared with the diameter after angioplasty. This was defined as elasticity or recoil. There was a significant direct correlation between the amount of elasticity and the extent of balloon inflation at 6 atm (that is, lesions more fully dilated at 6 atm showed more elasticity).(ABSTRACT TRUNCATED AT 250 WORDS)

Angiography↗

Coronary excimer laser angioplasty: reduced complications and indium-111 platelet accumulation compared with thermal laser angioplasty.

The relative safety and thrombogenicity of pulsed excimer and thermal laser angioplasty systems were compared in 20 normal coronary artery segments in a total of seven pigs. Using similar over the wire catheter systems and laser delivery periods of 3 to 5 s, thermal laser angioplasty was achieved with a 1.3 mm metal probe heated with 10 W of continuous argon laser energy and excimer laser angioplasty was performed with a 4.5F excimer laser catheter consisting of 13 concentrically arranged 200 microns fiber optics delivering 35 to 40 mJ/mm2 of xenon chloride (308 nm) excimer laser irradiation at a repetition rate of 25 to 30 Hz and a pulse duration of 120 ns. On angiography, the incidence of vessel perforation (1 in 10 versus 3 in 10) and abrupt vessel closure (0 in 10 versus 2 in 10) was less with excimer compared with thermal laser angioplasty. Macroscopically, there was a greater incidence of mural and occlusive thrombus formation after thermal laser than after pulsed excimer laser angioplasty. Histologic examination confirmed that this thrombogenicity was associated with greater charring and coagulation necrosis of the media. Quantitative indium-111-labeled platelet deposition was significantly increased after thermal laser angioplasty (median 87.2 x 10(6)/cm length) compared with excimer-treated (0.4 x 10(6)/cm length) or control (1.2 x 10(6)cm length) segments (p less than 0.001). Thus, excimer laser angioplasty was found to result in fewer complications and, as a consequence, less thrombosis and platelet accumulation than did thermal laser angioplasty.

Angioplasty, Balloon, Coronary↗

Exercise-induced pulmonary blood volume changes and diastolic dysfunction of the aged heart.

Impaired diastolic function has been described in healthy elderly subjects. Pulmonary blood volume (PBV) changes with exercise have been associated with left ventricular dysfunction, but not directly related to diastolic abnormalities. Exercise-induced relative changes in PBV were measured using gated blood pool imaging with count density comparisons over the lung in 20 healthy volunteers: 13 elderly, age 76 +/- 5 years and seven young, age 27 +/- 4 years. Serial (first exercise stage, peak exercise, and post exercise) PBV ratios were measured and correlated to peak early filling rate, peak late filling rate, and percent atrial filling obtained from the resting left ventricular time-activity curve analysis. PBV ratios tended to be higher in elderly subjects, but reached significance only at the first stage of exercise (1.04 +/- 0.07 vs. 0.93 +/- 0.10, p less than 0.01). Significant correlations were found between PBV ratios at first exercise stage and peak early filling rate (r = -0.64), peak late filling rate (r = 0.47), and percent atrial filling (r = 0.48). A significant correlation was found between PBV changes at peak exercise and resting diastolic parameters. Exercise-induced PBV changes are associated with left ventricular diastolic dysfunction at rest. Diastolic abnormalities of the aged heart may explain the differential PBV response early into exercise between young and elderly healthy subjects.

Adult↗

The role of silent ischemia, the arrhythmic substrate and the short-long sequence in the genesis of sudden cardiac death.

To study the role of silent ischemia and the arrhythmic substrate in the genesis of sudden cardiac death, 67 patients were studied (mean age 62 +/- 12 years). Of these, 14 patients (Group 1) had an in-hospital episode of ventricular tachycardia or fibrillation while wearing a 24 h Holter ambulatory electrocardiographic (ECG) monitor, 33 (Group II) had a documented episode of sustained ventricular tachycardia or fibrillation, or both, and 20 (Group III) had angina pectoris but no ventricular tachycardia or fibrillation. Eight Group I survivors underwent programmed electrical stimulation or ECG signal averaging, or both. All Group II patients underwent 24 h Holter monitoring and ECG signal averaging to detect late potentials before programmed electrical stimulation. Group III patients underwent both 24 h Holter recording and coronary angiography. The 24 h ECG tapes were analyzed for ST segment changes, prematurity index and characteristics of ventricular premature depolarizations. Any ST depression greater than or equal to 1 mm for greater than 30 s was considered to be a reflection of silent ischemia, and the induction of ventricular tachycardia or fibrillation by programmed electrical stimulation or the presence of late potentials, or both, was considered to be a reflection of the arrhythmia substrate. Silent ischemia preceded ventricular tachycardia in only 2 (14%) of the 14 Group I patients. The prematurity index was less than 1 in only 18% of ventricular tachycardia episodes.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Isolated chronic mitral regurgitation with preserved systolic left ventricular function and severe pulmonary hypertension.

Pulmonary hypertension in chronic mitral valve disease has been related most commonly to left ventricular dysfunction or mitral stenosis; its association with chronic, isolated mitral regurgitation and preserved left ventricular systolic function is unclear. In 41 catheterized patients with chronic mitral regurgitation (known history of mitral regurgitation for greater than 18 months) and preserved left ventricular systolic function (ejection fraction greater than 0.55), historic, electrocardiographic, echocardiographic and hemodynamic variables were analyzed. Ten patients (Group I) had normal pulmonary artery systolic pressure (less than 30 mm Hg), whereas 31 patients had pulmonary hypertension. Pulmonary artery systolic pressure was mildly increased (30 to 49 mm Hg) in 13 patients (Group II) and was greater than or equal to 50 mm Hg in 18 patients (Group III). Univariate analysis showed the more frequent occurrence of male gender and ruptured chordae tendineae in the groups with pulmonary hypertension. Mean pulmonary capillary wedge pressure, size of the V wave in pulmonary capillary wedge pressure and pulmonary arteriole resistance were higher, whereas cardiac index was lower in the hypertension groups. Multivariate stepwise analysis revealed higher mean pulmonary capillary wedge pressure and pulmonary arteriole resistance as the only variables independently differing among groups. In conclusion, pulmonary hypertension occurs frequently (76% of cases) in patients with chronic, isolated mitral regurgitation with preserved left ventricular systolic function. In these patients, a severe increase in pulmonary capillary wedge pressure is associated with elevation in pulmonary artery resistance, a finding similar to that in mitral stenosis.

Echocardiography↗