PubMed Health⌕ Search

Biomedical subjects

D B Drake

Publications and source records attributed to D B Drake.

At least 19 recordsLinked to original sources

An outcome study of breast reconstruction: presurgical identification of risk factors for complications.

BACKGROUND: Breast reconstruction following mastectomy has been shown to have a salutary effect on the overall psychological well-being of women being treated for breast cancer. Unfortunately, however, not every patient is an ideal candidate for reconstruction. Complications stemming from reconstructive surgery can cause significant morbidity, the most important of which may be the delay of subsequent adjuvant antineoplastic therapies, and therefore may not be in the best interests of the patient. METHODS: A retrospective study was performed on a consecutive series of 123 breast reconstructions in 98 patients, performed by one of two plastic surgeons, in a university setting over a 5-year period, for all surgical outcomes. Specifically, wound-healing complications, infections, and reoperations leading to the potential delay of subsequent chemotherapy or radiotherapy were recorded, and possible risk factors leading to these were sought. RESULTS: Three presurgical risk factors were found to have a statistically significant influence on the development of complications following breast reconstruction. These were: (1) increasing obesity, defined by the body mass index, (2) an active or recent (<5 year) history of cigarette smoking, and (3) a history of previous radiation exposure. Odds ratios were used to describe the magnitude of the effect of each factor for the development of complications. An ordinal regression analysis was used to create a nomogram based on this information that can be used to calculate any individual patient's presurgical risk for developing major complications following breast reconstruction, based on the presence of these factors. CONCLUSIONS: It is possible, based on the presence of specific presurgical risk factors, to predict the probability of developing major complications following breast reconstruction. This information can be useful to the referring physician and plastic surgeon alike in determining which patients are the best candidates for breast reconstruction and which type of reconstruction would be best suited for each individual patient.

Adult↗

Fibrin sealant: a novel method of fixation for an implantable ultrasonic microDoppler probe.

While free tissue transfer affords the reconstructive microvascular surgeon the ability to provide coverage for complex wounds, the postoperative monitoring of these flaps continues to evolve. The most recent advance has been the development of an implantable microDoppler probe to provide an early warning signal for vascular obstruction. The current system relies on the use of a silicone cuff to secure a 1-mm probe to the outflow vein. The release force to remove the probe from the cuff is reported to be 1/10 of a pound (45 g). A disadvantage of this system is the need for a circumferential, relatively inelastic device around the vein. Should the cuff be too tightly secured to the vein, the potential for outflow obstruction exists. Moreover, if the probe is not well-approximated to the vein, no signal is produced. Finally, the fact that a foreign body remains in the wound after completion of the monitoring period remains a concern. The authors have investigated a new method to adhere the probe, using a commercially available fibrin sealant. The use of this biocompatible substance has the potential to obviate the need for the current method of fixation, and the associated concerns.

Animals↗

The vacuum-assisted closure device as a bridge to sternal wound closure.

Sixteen patients were treated for sternal wound infections after undergoing cardiac procedures. Their management involved prompt surgical debridement and quantitative wound biopsies. At the time of the initial debridement, the Vacuum-Assisted Closure Device (V.A.C.) was placed in the open sternal wound. A subatmospheric environment was maintained by the device at a level of 75 to 150 mmHg. The V.A.C. sponge was changed every 2 to 3 days, and operative debridement was performed until quantitative biopsies showed resolution of infection or until systemic signs of sepsis had resolved. At this time the sternal wounds were closed with regional muscle flaps. Patients were excluded from the use of the device if the pleural cavity was entered during operative debridement. Fifteen of the 16 patients survived and went on to complete wound healing and discharge from the hospital (average length of stay, 16.7 days). One patient sustained a cardiac dysrhythmia during the muscle flap procedure and died. There were no complications related directly to the use of the V.A.C. It is the opinion of the authors that the V.A.C. offers several advantages over their traditional methods of treatment. They noted improvement in sternal wound stabilization during the perioperative period and a decreased need for paralysis and mechanical ventilation. Wound management was improved by avoiding the need to perform debridement or to make desiccating dressing changes to an open sternum. Moreover, they also think that this device may lessen the risk for ventricular rupture because of better control of the wound environment and markedly improved stabilization of the debrided sternal elements.

Aged↗

An innovative absorbable coating for the polybutester suture.

The polybutester (PBE) suture has been coated with an absorbable polytribolate polymer that is composed of glycolide (9%), epsilon-caprolactone (51%), and poloxamer 188 (40%) to reduce its drag forces. It is the purpose of this study to document the influence of this coating on the biomechanical performance of both PBE sutures and polypropylene (PP) sutures. The performance parameters evaluated were breaking strength, elongation, stiffness, knot security, knot run down, and tissue drag. The breaking strength of PP sutures was remarkably similar to that of coated and uncoated PBE sutures. In size 5/0 PP sutures, the sutures exhibited considerably greater elongation at knot break than did comparably sized PBE sutures. The PBE suture elongated under low loads, but returned to its original length when the load was removed. In contrast, the PP suture elongated irreversibly at high loads, exhibiting creep. Coated and uncoated PBE sutures exhibited less stiffness than PP sutures and exhibited limited memory after removal from the suture package. Coating the PBE suture markedly reduced its drag forces in musculoaponeurotic, colonic, and vascular tissue. Knot security with the coated PBE suture was achieved with only one more throw than with comparably sized uncoated PBE sutures. On the basis of the results of this study, coating the PBE suture represents another major advance in suture performance.

Abdominal Muscles↗

Fibrin sealants in microvascular surgery: current status.

During the last two decades, advances in fibrin sealant formulation have resulted in its investigational and clinical use in various surgical endeavors, including microvascular surgery. Several investigations have comparatively evaluated fibrin adhesive-enhanced microvascular anastomoses vs. conventional suture repair. The purpose of this review is to summarize the collective documentation on fibrin adhesives in microvascular surgery on the basis of the scientific performance parameters of vessel patency, bursting strength, anastomotic competence, and reendothelialization. In addition, other applications of fibrin sealants and other qualities unique to fibrin adhesives are addressed.

Animals↗

A pilot study of short- and long-term sequelae to rigid fixation across metacarpal physes in a baboon model.

The use of rigid fixation for fractures of the extremities has become commonplace. The short- and long-term effects of rigid fixation on the growing hand, however, have not been studied thoroughly. In this project, the use of rigid fixation across metacarpal growth plates (physes) in growing primate hands was examined. The hypothesis to be tested was that long-term placement of rigid fixation devices across physes during stabilization of mid-shaft osteotomies will cause the physes to close prematurely. Fixation devices with screws placed in the epiphysis and left in place for 4 months or 1 year resulted in open physes, in support of the null hypothesis. However, in physes plated for 1 year, biochemical changes associated with increased bone differentiation were apparent. Findings suggest that rigid fixation across physes for as long as 1 year can be used appropriately in growing individuals when necessary. However, until additional investigation establishes whether the open physes are still capable of producing bone-lengthening hypertrophic chondrocytes, caution should be used in long-term placement of rigid fixation devices.

Animals↗

Thrombogenic effects of a nonthrombin-based fibrin sealant compared with thrombin-based fibrin sealant on microvenous anastomoses in a rat model.

The efficacy and safety of tissue adhesives needs to be clearly defined. A thrombin-based preparation of fibrin sealant has recently been shown to have deleterious effects on microvascular anastomoses in an animal model. The authors found that fibrin sealant constructed with a high concentration of bovine thrombin (1,000 IU per milliliter) was detrimental to microvascular patency when applied to the anastomosis in a rat free flap model. The microvenous anastomosis had the highest rate of thrombosis and failure in this model. A nonthrombin-based fibrin sealant has recently become available for experimental investigation. This study examined the thrombogenic effect of this nonthrombin-based fibrin sealant on microvenous anastomoses in a rat free flap model compared with the effect of traditionally prepared fibrin sealant with varying concentrations of thrombin. The conclusions reveal that flap survival with application of the nonthrombin-based fibrin sealant to the anastomosis was comparable with flap survival of the control animals. Flap survival with application of the traditionally prepared thrombin-based fibrin sealant was also comparable with flap survival of the control animals when a concentration of 500 IU per milliliter of thrombin was used. However, flap survival decreased significantly (p <0.005) when a concentration of 1,000 IU per milliliter of thrombin was used in the construct of the fibrin adhesive. These results support the previous findings of the harmful effects of thrombin when used in high concentrations and applied to the microvenous anastomosis of this free flap model. Moreover, this initial investigation with a nonthrombin-based fibrin sealant did not show any deleterious effects on the microvenous anastomosis compared with control animals.

Anastomosis, Surgical↗

Wound complications of abdominoplasty in obese patients.

The records of 90 patients who underwent an abdominoplasty at the University of Virginia Health Sciences Center were analyzed to determine the effect of obesity on the incidence of complications after this surgery. The study patients were divided into three groups-obese, borderline, and nonobese-based on the degree to which their preoperative weights varied from their ideal body weight. A history of previous bariatric surgery was also analyzed to determine what impact that might have on subsequent abdominoplasty. Results showed that 80% of obese patients had complications compared with the borderline and nonobese patients, who had complication rates of 33% and 32.5% respectively (p = 0.001). Previous gastric bypass surgery had no significant effect on the incidence of postabdominoplasty complications. Based on these findings the authors conclude that obesity at the time of abdominoplasty has a profound influence on the wound complication rate following surgery, regardless of any previous weight reduction surgery.

Adult↗

A new technique for the treatment of flexor digitorum profundus tendon avulsion.

Current treatment of flexor digitorum profundus (FDP) avulsion with complex external wire or button fixation is associated with significant morbidity. A new method of internal fixation avoids the complications that are associated with previous techniques. Through a volar Bruner incision, the profundus tendon is retrieved. A transverse dorsal incision is made and two holes are drilled. A double-arm suture is passed through the tendon and bone, and is tied dorsally. Both incisions are closed, leaving the repair entirely internal. This simple technique produces a solid reinsertion of the FDP tendon and avoids damage to the nail bed and matrix. Internal fixation eliminates nail plate deformities, reduces cost, speeds recovery, and produces a stable reconstruction.

Finger Injuries↗

A temporal analysis of the effects of pressurized oxygen (HBO) on the pH of amputated muscle tissue.

The effect of hyperbaric oxygen (HBO) on ischemic muscle tissue pH was evaluated continuously. The hind limbs of male Sprague-Dawley rats (N=11, both groups) were amputated and stored in room air (20.1% oxygen [O2], 1.0 ATM, 24 degrees C) or in HBO (100% O2, 2.9 ATM, 24 degrees C) for 240 minutes. Rat muscle tissue pH was continuously monitored with a micro-pH electrode following amputation. There was no significant difference between the average starting tissue pH of control and treated limbs (p=0.45). At 240 minutes of ischemia the control group tissue pH decreased 0.80 pH units whereas the treatment group decreased 0.68 pH units (p < 0.05). The tissue pH of control limbs declined 30.7 times faster than treated limbs during the first 36 minutes of ischemia (p < 0.05). From 36 to 240 minutes the rates of acidosis were similar and did not differ significantly (p=0.46). In a separate study, male Sprague-Dawley rats were anesthetized with pentobarbital and ketamine. Aortic arterial blood gases were obtained at 5 minutes (N=8) and 15 minutes (N=8) postanesthesia. The average serum pH, carbon dioxide, oxygen, and bicarbonate levels remained within normal limits in both groups and did not differ significantly (p > 0.05 for all parameters). Anesthesia produced no serum respiratory or metabolic acidosis and did not contribute to the initial ischemic tissue pH. These results suggest that HBO delays the progression of metabolic acidosis in this amputated limb model. This is further supporting evidence for the tissue-preserving effect of oxygen when delivered in hyperbaric conditions. However, the clinical application of this technique may be limited due to the difference in the volume of tissue presented for major limb replantation and the short window of beneficial effects.

Acidosis↗

Acute thrombogenic effects of fibrin sealant on microvascular anastomoses in a rat model.

Topically applied bioadhesives and hemostatic agents have gained wide acceptance in various surgical endeavors. However, the effect of thrombin-based fibrin sealant (fibrin glue) when applied to microvascular anastomoses has not been evaluated thoroughly. Although fibrin sealant has been used directly on vascular anastomoses in macrovascular surgery, there has been little exploration into the utility and potential complications when used in the microsurgical setting. This study explored the influence of fibrin sealant containing increasing concentrations of bovine thrombin on microvascular anastomoses in a rat epigastric free flap model. The survival of the free flap in this model appeared to be inversely proportional to the concentration of thrombin in the fibrin sealant. When thrombin alone was applied to the anastomoses, the rate of thrombosis was the highest. Venous anastomosis was the most sensitive to the deleterious effects of topically applied thrombin.

Anastomosis, Surgical↗

Influence of latex glove hydration on bacteriophage penetration.

The purpose of this study was to determine whether glove hydration influenced bacteriophage penetration. Using an electronic glove hole-detection device, one brand of latex glove was identified that hydrated rapidly (3.25 min +/- 0.71 min), while another brand was selected that resisted hydration (120 min +/- 0 min). Using a standard bacteriophage penetration model, the amount of bacteriophage penetration in both the rapidly hydrating gloves and the gloves that resisted hydration was extremely small and did not differ significantly from each other.

Bacteriophage phi X 174↗

Peritoneal healing with adhesion formation: current comment.

Intra-abdominal adhesions are fibrotic structures, which lie in the form of a string or attachment between the abdominal organs and connect these together. They are responsible for serious clinical complications that include intestinal obstruction, infertility, and pelvic pain. During the last century, surgeons' comprehensive understanding of the biology of peritoneal healing and wound repair has allowed them to identify a variety of new therapeutic techniques that limit the development of adhesion formation. New drugs, dextran 70 and poloxamer 407, have been developed to prevent adhesion formation. In addition, three new biomaterials (oxidized regenerated cellulose, hyaluronate membrane, and polytetrafluoroethylene) are synthetic barriers being used to prevent adhesions.

Biocompatible Materials↗

A new computerized control unit for small bone surgical instruments.

The SmartDrive console represents an important advance in small bone surgery because it monitors and coordinates the operation of its handpieces. The SmartDrive console has the following unique features: 1) a handpiece recognition system; 2) an instrument speed display; 3) a handpiece display and monitoring system; 4) a torque instrument control system; 5) a temperature monitoring system; 6) and an irrigation system. Mechanical performance studies have been undertaken that have validated the accuracy of the monitoring systems of the consoles. The consoles provided reliable recordings of the rotational speeds of their hi-speed drills. The MicroAire console automatically shuts off its power as the temperature increased to 110 degrees F (43 degrees C). In contrast, the Stryker Command 2 console has a limited monitoring system that can not alter the operation of the handpieces.

Bone and Bones↗

Effect of puncture resistant surgical gloves, finger guards, and glove liners on cutaneous sensibility and surgical psychomotor skills.

New puncture and cut resistant hand protection systems have been developed to enhance the barrier to cuts and needle puncture injuries during surgical procedures. It is important, however, that these new hand protection systems do not reduce tactile sensitivity or dexterity during surgery. Consequently, it was the purpose of this report to compare the cutaneous sensibility and dexterity of physicians' hands covered by these new puncture and cut resistant hand protection systems to that of the standard surgical latex glove. The hide (Medak) portion of the Life Liner and the polyethylene (Spectra) portion of the FingGuard, which offered the greatest resistance to needle puncture, were associated with the greatest reduction in cutaneous sensibility, as determined by moving and static two-point discrimination, aesthesiometer pressure sensation, and discrimination of suture size and configuration. In addition, the physicians believed that the puncture and cut resistant Life Liner glove liner markedly interfered with their handling of surgical instruments. The ultimate benefit of these puncture and cut resistant hand protection systems must be determined in well-controlled clinical trials.

Discrimination, Psychological↗

New instruments, bone liners, and tray for finger joint arthroplasty.

Titanium circumferential grommets have been developed for finger joint arthroplasty that fit on the base of the silicone implant stems to protect the flexible hinge from tearing and fracture. To facilitate grommet insertion, new intramedullary bone rasps have been devised with a reverse cutting tooth pattern, an extended shaft for an improved view of the surgical field, and a redesigned cutting head to allow for grommet insertion. Surgical accessibility and ease of recognition have been facilitated by the development of color-coded sizers. All of the instruments necessary for finger joint surgery are available in a molded tray that has also been redesigned with a transparent lid and clearly labeled compartments for accurate determination of instruments and implant sizers.

Equipment Design↗