PubMed Health⌕ Search

Biomedical subjects

D Baleanu

Publications and source records attributed to D Baleanu.

6 recordsLinked to original sources

[Telemedical-supported screening of retinal vessels ("talking eyes")].

BACKGROUND: Cerebral and retinal vessels behave similarly under the influence of vascular risk factors. Several groups have shown that retinal microvascular abnormalities represent an independent risk factor with regard to strokes and heart attacks. AIM OF THE STUDY: The aim of this study was to perform a prospective screening examination with regard to retinal microvascular abnormalities as well as an extended vessel diagnosis in a subgroup of patients with lower arteriovenous risk values. METHODS: In the course of a prospective cross-sectional study ("Talking Eyes") between 1.9.2001 and 1.8.2002 a telemedical-supported screening of the retina (study I) was carried out in 7,163 subjects. The patients were selected without any inclusion or exclusion criteria. The mean age was 48.2 +/- 8 years (18 - 83 years) with a sex distribution of 39.2 % females to 60.8 % males. Digital fundus photos of the right and left eyes were taken for all patients. The pictures were taken without pupil dilation using a CANON-NM camera. The pictures and case histories were stored in a central server using web-based software (MedStage, Siemens). In a central reading centre, the arteriovenous ratio of both eyes was determined telemedically using the Parr-Hubbard formula and the retinas subjected to a standardised examination by an ophthalmologist. The retinal risk factor was calculated on the basis of the arteriovenous ration, the presence of microvascular abnormalities and the case history. The reproducibility of measurement of the arteriovenous ratio (Kronbach alpha coefficient) was evaluated by double measurements on 1,332 images. In a subgroup of study I with arteriovenous ratio values < 0.76 (N = 107), an extended vessel diagnosis with measurement of 24-h blood pressure and vessel-relevant blood values (homocysteine, cholesterol, LDL, HDL, CRP, TG, HbA1c) was carried out (study II). RESULTS: Study I: The Kronbach alpha coefficient as a measure of reproducibility amounted to 0.77. The mean arteriovenous ratio of the retinal vessels was 0.83 +/- 0.09 and showed a pronounced age dependence (R = 0.9, p < 0.0001). On multivariate testing the arteriovenous ratio correlated significantly (R = 0.33, p < 0.001) with the factors age, systolic blood pressure, diastolic blood pressure and body mass index. Diastolic blood pressure followed by age had the largest influence. The prevalence of microvascular abnormalities in the right (RE) and left (LE) eyes, respectively were: cotton wool foci RE 0.0015 %, LE 0.003 %, retinal haemorrhage RE 0.1 %, LE 0.1 %, focal stenoses RE 3.4 %, LE 3.4 %, tortuositas vasorum RE 4.1 %, LE 4.0 %, arteriovenous crossing signs RE 11.2 %, LE 11.2 %. On multivariate testing the occurrence of microvascular abnormalities correlated significantly (R = 0.38, p < 0.001) with the factors high blood pressure known from case history, body mass index, and gender. Arterial hypertension had the strongest influence followed by diastolic blood pressure. The calculated retinal risk factor correlated with the prevalence of angina pectoris. Study II: 2/3 of the subjects with arteriovenous risk factor values < 0.76 exhibited pathologically high 24-h blood pressure values. For these patients there were significant correlations between the arteriovenous ratio and the low-density lipoprotein concentration as well as the Framingham risk score. CONCLUSION: In the course of a prospective, telemedical-supported screening examination of the retinal vessels of more than 7,000 subjects the arteriovenous ratio exhibited a strong dependence on age and blood pressure. Among the subjects with lowered arteriovenous ratio values, 2/3 exhibited arterial hypertension in the 24-h blood pressure determination.

Adolescent↗

[Diagnostics and therapy for normal tension glaucoma].

Pooled data from "The Baltimore Eye Survey", "The Blue Mountains Eye Study", "The Beaver Dam Eye Study", "The Rotterdam Study" and "The Melbourne VIP" showed a strong age-dependent prevalence of open angle glaucoma. Patients younger than 60 years have a prevalence of open angle glaucoma of less than 1 %. Beginning with the age of 60 the prevalence increases exponentially. The prevalence of open angle glaucoma in persons in the 8(th) age decade reaches up to 5 %. Among these patients, 30-50 % have normal intraocular pressure. The diagnostics and therapy for open angle glaucoma with normal intraocular pressure (IOP), also called normal tension glaucoma, is a complex and often interdisciplinary challenge. Established causative factors for developing a glaucomatous optic nerve atrophy in normal tension glaucoma are: relatively increased IOP, older age, non-dippers (0-10 %) or extreme dippers (> 20 %) concerning nocturnal arterial blood pressure drop, small vessel disease with cardiovascular disease and cerebral microgliosis (white matter lesions), decreased blood flow in the optic nerve head, extreme dip of the optic nerve head blood flow in the morning, cerebral blood flow dysregulation and the epsilon4-allele polymorphism of the apolipoprotein E-gene. Clinical pathways are presented for the diagnostics and therapy for normal tension glaucoma.

Glaucoma, Open-Angle↗

Comparative application of wavelet approaches to absorption and ratio spectra for the simultaneous determination of diminazene aceturate and phenazone in veterinary granules for injection.

A comparison of two wavelet approaches, Daubechies and reverse Biorthogonal, is described for the quantitative resolution of a binary mixture of diminazene aceturate (DIMA) and phenazone (PHE) in veterinary granules for injection without any chemical separation. These two approaches were specified as db4 (a = 180) and rbior3.7 (a = 125) respectively, after testing the signal analysis parameters for the overlapping absorption spectra and ratio spectra. In the first step db4 (a = 180) was applied to the original absorbance data vector of DIMA and PHE. In the second step rbio3.7 (a = 125) was applied to the ratio spectra data vectors of DIMA using the divisor PHE. The same approach was also subjected to the ratio spectra of PHE using the divisor DIMA. The db4 (a = 180) and rbior3.7 (a = 125) calibration graphs were constructed using the transformation values obtained in the wavelet domain. In the method validation, the wavelet calibration functions were tested using synthetic mixtures and the standard addition technique. The simultaneous quantitative analysis of DIMA and PHE in the commercial veterinary preparation was achieved by the elaborated methods. The assay results were compared with each other and good agreement was observed.

Algorithms↗

Continuous wavelet transformation applied to the simultaneous quantitative analysis of two-component mixtures.

In this paper we developed a graphical method based on Haar (HA) and Mexican (MEX) one-dimensional continuous wavelet transforms and we applied it to a mixture of hydrochlorothiazide (HCT) and spironolactone (SP) in the presence of strongly overlapping signals. Keeping in mind to obtain an appropriately transformed spectrum, we tested several values of the scaling parameter a and the point number of the analysed spectrum in the concentration range of 2-22 microg/ml for both active compounds. The optimal values of the scale parameters and the corresponding frequencies were found to be a = 32 and 0.031 for HA and a = 30 and 0.008 for MEX corresponding to 400 points. HA and MEX methods based on a zero crossing technique were applied to the analysed signal and their regression lines at the selected points were obtained. The validation of the above methods was carried out by analysing different synthetic mixtures containing HCT and SP. MATLAB 6.5 software was used for one-dimensional wavelet analysis and the basic concepts about wavelet method were briefly explained. The method developed in this paper is rapid, easy to apply, inexpensive and is suitable for analysing the overlapping signals of compounds in their mixtures without any chemical pre-treatment.

Algorithms↗

Two new spectrophotometric approaches to the multicomponent analysis of the acetaminophen and caffeine in tablets by classical least-squares and principal component regression techniques.

Classical least-squares (CLS) and principal component regression (PCR) techniques were proposed for the simultaneous analysis of tablets containing acetaminophen and caffeine without using a chemical separation procedure. The chemometric calibrations were prepared by measuring the absorbances values at the 15 wavelengths in the spectral region 215-285 nm and by using a training set of the mixtures of both drugs in 0.1 M HCI. The obtained chemometric calibrations were used for the estimation of acetaminophen and caffeine in samples. The numerical calculations were performed with the 'MAPLE V' software. By applying two techniques to synthetic mixtures, the mean recoveries and the relative standard deviations in the CLS and PCR techniques were found as 99.5 and 1.29, 99.7 and 1.00% for acetaminophen and 99.9 and 1.92, 100.0 and 1.178% for caffeine, respectively. Our results were compared with those obtained previously by one of us considering HPLC method as a reference method. These two methods were successfully applied to a pharmaceutical tablet formulation of two drugs.

Acetaminophen↗

Spectrophotometric multicomponent analysis of a mixture of metamizol, acetaminophen and caffeine in pharmaceutical formulations by two chemometric techniques.

Inverse least squares (ILS) and factor-based (principal component analysis (PCA)) techniques were proposed for the spectrophotometric multicomponent analysis of a ternary mixture consisting of metamizol, acetaminophen and caffeine, without prior separation. In these chemometric techniques, the measurements of the absorbance values were realized in the spectral range from 225 to 285 nm in the intervals of Deltalambda=5 nm at the 13 wavelengths in the zero-order spectra of the different ternary mixtures of these active ingredients in 0.1 M HCl. The prepared calibrations of both techniques using the absorbance data and concentration matrix data sets were used to predict the concentration of the unknown concentrations of metamizol acetaminophen and caffeine in their ternary mixture. The 'MAPLE V' software was used for the numerical calculations. Mean recoveries and relative standard deviations for ILS and PCA techniques were found to be 99.8 and 1.68%, 99.9 and 1.66% for caffeine, 99.8 and 1.84%, 100.4 and 2.85% for metamizol, and 99.7 and 1.04%, 99.6 and 1.34% for acetaminophen, respectively, for the first and second techniques. The techniques were successfully applied to two pharmaceutical formulations marketed in Turkey and results were compared with a new high-performance liquid chromatography method.

Acetaminophen↗