PubMed Health⌕ Search

Biomedical subjects

D Barceló

Publications and source records attributed to D Barceló.

At least 19 recordsLinked to original sources

Recently developed GC/MS and LC/MS methods for determining NSAIDs in water samples.

Pharmaceuticals have become major targets in environmental chemistry due to their presence in aquatic environments (following incomplete removal in wastewater treatment or point-source contaminations), threat to drinking water sources and concern about their possible effects to wildlife and humans. Recently several methods have been developed for the determination of drugs and their metabolites in the lower nanogram per litre range, most of them using solid-phase extraction (SPE) or solid-phase microextraction (SPME), derivatisation and finally gas chromatography mass spectrometry (GC-MS), gas chromatography tandem mass spectrometry (GC-MS/MS) and liquid chromatography electrospray tandem mass spectrometry (LC-ES/MS/MS). Due to the elevated polarity of non-steroidal anti-inflamatory drugs (NSAIDs), analytical techniques based on either liquid chromatography coupled to mass spectrometry (LC-MS) and gas chromatography coupled to mass spectrometry (GC-MS) after a previous derivatisation step are essential. The most advanced aspects of current GC-MS, GC-MS/MS and LC-MS/MS methodologies for NSAID analysis are presented.

Anti-Inflammatory Agents, Non-Steroidal↗

The integrated project AquaTerra of the EU sixth framework lays foundations for better understanding of river-sediment-soil-groundwater systems.

The integrated project "AquaTerra" with the full title "integrated modeling of the river-sediment-soil-groundwater system; advanced tools for the management of catchment areas and river basins in the context of global change" is among the first environmental projects within the sixth Framework Program of the European Union. Commencing in June 2004, it brought together a multidisciplinary team of 45 partner organizations from 12 EU countries, Romania, Switzerland, Serbia and Montenegro. AquaTerra is an ambitious project with the primary objective of laying the foundations for a better understanding of the behavior of environmental pollutants and their fluxes in the soil-sediment-water system with respect to climate and land use changes. The project performs research as well as modeling on river-sediment-soil-groundwater systems through quantification of deposition, sorption and turnover rates and the development of numerical models to reveal fluxes and trends in soil and sediment functioning. Scales ranging from the laboratory to river basins are addressed with the potential to provide improved river basin management, enhanced soil and groundwater monitoring as well as the early identification and forecasting of impacts on water quantity and quality. Study areas are the catchments of the Ebro, Meuse, Elbe and Danube Rivers and the Brévilles Spring. Here we outline the general structure of the project and the activities conducted within eleven existing sub-projects of AquaTerra.

Climate↗

Optical immunosensor for fast and sensitive detection of DDT and related compounds in river water samples.

A surface plasmon resonance (SPR) based immunosensor has been developed for the monitoring of environmentally persistent pollutants like DDT, its metabolites and analogues in real water samples. A reusable immunosurface is provided via the covalent attachment of the analyte derivative to a self-assembled alkanethiol monolayer formed onto the SPR gold-thin layer. The regeneration of the sensor surface allowed the performance of 270 assay cycles within an analysis time of 20 min for each assay cycle. Immunoassays based on a binding inhibition format were performed by using two monoclonal antibodies (MAbs) with different selectivity. Low limits of detection (LODs), in the sub-nanogram per litre range, were attained for DDT-selective (15 ng L-1) and DDT group-selective immunoassays (31 ng L-1). Both assays were carried out in spiked river water samples without significant effect of the matrix. SPR measurements were validated using gas-chromatography-mass spectrometry. The comparison between methods was in good agreement showing an excellent correlation coefficient (r2=0.995). The SPR analysis of DDT proved to be three times more sensitive than colorimetric ELISAs without the need of labelling and a much lower time of response. Our SPR biosensor portable platform (beta-SPR) is already commercialised by the company SENSIA, S.L. (Spain).

Antibodies↗

Radiolytic decomposition of multi-class surfactants and their biotransformation products in sewage treatment plant effluents.

Electron beam irradiation (EBI), as one of the most efficient advanced oxidation processes, was applied to the treatment of sewage treatment plant (STP) effluent, with the objective of evaluating the effectiveness of radiolytic decomposition of multi-class surfactants. Target compounds, included several high-volume surfactant groups, such as alkylphenol ethoxylates (APEOs) and their biotransformation products, linear alkylbenzene sulfonates (LAS), alkyl sulfates (AS), alkylether sulfates (AES), coconut diethanol amides (CDEA), alcohol ethoxylates (AEO) and polyethylene glycols (PEGs). EBI treatment of STP effluent (total concentration of APEO-derived compounds 265mugl(-1), being APE(2)C the most abundant by-degradation products) resulted in efficient decomposition of all alkylphenolic compounds; elimination of 94% longer ethoxy chain nonylphenol ethoxylates (NPEO, n(EO)=3-15) was obtained when 3kGy were applied. Slightly less efficient decomposition of short ethoxy chain oligomers (NPEO(1) and NPEO(2)) was observed, resulting in disappearance of about 80% of the initially present compounds. LC-MS analysis of treated wastewater suggested that the mechanism of EBI degradation of APEOs is a combination of two parallel pathways: a progressive shortening and oxidation of the ethoxy chain, which resulted in a formation of short ethoxy chain oligomers and APECs and central fission that resulted in formation of PEGs. Decomposition of APECs at 1kGy initially yielded APs, which were subsequently eliminated applying higher radiation doses. With a radiation dose of 2kGy about 95% of NPE(1)C and 97% of NPE(2)C were decomposed. Similar elimination rates were obtained for octylphenolic compounds. Radiolytic treatment applied was also very effective in removing PEGs formed as by-products from APEO degradation, as well as in decomposing other surfactants, such as linear LAS, AS and AES.

Alkanesulfonic Acids↗

Trace-level determination of pharmaceutical residues by LC-MS/MS in natural and treated waters. A pilot-survey study.

A pilot-survey study was performed by collecting samples (influent and effluent wastewaters, rivers and tap waters) from different locations in Europe (Spain, Belgium, Germany and Slovenia). A solid-phase extraction (SPE) followed by liquid chromatography-tandem mass spectrometry method was applied for the determination of pharmaceuticals (ibuprofen, naproxen, ketoprofen, diclofenac and clofibric acid). Method detection limits and method quantification limits were at the parts-per-trillion level (7.5-75 ng/L). The recovery rates of the SPE from deionized water and effluent wastewater samples spiked at 100- and 1,000-ng/L levels ranged from 87 to 95%. Identification criteria in compliance with the EU regulation for confirmatory methods of organic residues were applied. A detailed study of signal suppression evaluation for analysis of pharmaceutical residues in effluent wastewaters is presented.

Chromatography, Liquid↗

Presence of surfactants and their degradation intermediates in sediment cores and grabs from the Cadiz Bay area.

The occurrence and distribution of the major surfactants--LAS, AES, APEOs and AEOs--and their degradation intermediates--SPCs, AP and APECs--in a marine-estuarine environment at Spain are presented. Results show that their concentration in surface sediments is clearly correlated with their usage and the existence of wastewater discharges. The degradation processes appear to lead to the formation of SPCs in the case of LAS, and to the shortening of the average ethoxylated chain length in the case of NPEOs, AEOs and AES. Vertical profiles for AEOs and AES are reported for the first time and present the highest values nearest the surface, followed by a sharp decrease with depth for all surfactants, as well as the appearance of degradation intermediates in deeper sedimentary layers. Shorter LAS homologues and SPCs tend to be present in pore water while strongly non-polar intermediates like NP are firmly attached to the sediments.

Biodegradation, Environmental↗

The occurrence of polybrominated diphenyl ethers in river and coastal biota from Portugal.

Throughout this work PBDEs level determination in biota was developed for the first time in Portugal. The data obtained was important to provide a global perspective of Portugal contamination by PBDEs and allows the comparison with studies made in other countries. Environmental levels of fourteen polybrominated diphenyl ethers (PBDEs) were analysed in a number of biota samples (Barbus sp. and Mytilus galloprovincialis) taken over a large geographic range covering five rivers and coastal areas of Portugal. Tetrabromodiphenyl ether (BDE 47) was found in almost all samples ranging from not detected (nd) to 30ngg(-1) dry weight (dw). BDE 47 concentration is correlated with mussels weight indicating the bioaccumulation of this compound. Pentabromodiphenyl ethers (BDE 99 and BDE 100) were detected in several samples, but in lower concentrations.

Animals↗

Application of liquid chromatography/quadrupole time-of-flight mass spectrometry (LC-QqTOF-MS) in the environmental analysis.

This paper gives an overview of the potentials of liquid chromatography-hybrid quadrupole time-of-flight mass spectrometry (LC-QqTOF) in the environmental analysis. Examples of applications of QqTOF instruments for target analysis of pharmaceuticals and pesticides are presented and discussed, as well as applications aimed on the identification of unknown compounds present in environmental waters or on the elucidation of structures of biodegradation and photodegradation products. Specific issues such as uncertainty of mass measurement and quantitative performances are discussed in details.

Chromatography, Liquid↗

A characterization of selected endocrine disruptor compounds in a Portuguese wastewater treatment plant.

Anthropogenic compounds that are able to disrupt the endocrine system of wildlife species are a major cause for concern and have led to a demand for new screening methods. The identification and quantification of endocrine disruptor compounds at wastewater treatment plant is of major interest to assess the endocrine activity of wastewater treatment plant discharges into the environment. This study consists of a preliminary survey of concentrations of previously selected endocrine disruptor compounds, undertaken to establish environmental concentrations and to support a biological program assay exposing freshwater fish to them. Selected endocrine disrupting chemicals (APEs, bisphenol A and 17 beta-estradiol) were measured in samples from a wastewater treatment plant located in Lisbon (Portugal), using recent commercial enzyme-linked immunosorbent assay kits and also LC-MS/MS. The results show that the wastewater treatment plant treatment process is efficient on the removal of target endocrine disruptor compounds. However, environmentally significant concentrations are still present in the treated effluent. The results also show that enzyme-linked immunosorbent assay kit is suitable for routine analysis of the selected compounds. The results are also useful since the wastewater treatment plant is located in a Mediterranean region, which results in an effluent with its own characteristics.

Benzhydryl Compounds↗

Analysis of bisphenol A in natural waters by means of an optical immunosensor.

This work describes a very simple, fast and sensitive method based on the use of the optical immunosensor "RIver ANAlyser" (RIANA) to the determination of bisphenol A in a waters. RIANA is based on a rapid solid-phase indirect inhibition immunoassay that takes place at an optical transducer chip chemically modified with an analyte derivative. Fluorescence produced by labelled antibodies bound to the transducer is detected by photodiodes and can be correlated with the analyte concentration. The sensor surface can be regenerated thus allowing the performance of several measurements (around 300) with the same transducer. Each test cycle, including one regeneration step, is accomplished in 15 min. The detection limit achieved in the direct determination of bisphenol A in water with this system was 0.014 microg/L. Satisfactory repeatability, with relative standard deviations (RSD) ranging between 1.48% and 6.93% were obtained. The immunosensor method developed was applied to the monitoring of bisphenol A in various types of water collected in a waterworks (from the river water source to the finished drinking water) and validated against the results obtained in the same approach by a more traditional method, based on solid-phase extraction followed by liquid chromatography-mass spectrometry. Results obtained by both techniques were in general good agreement (considering the typical overestimation bias of immunoassays), and served to prove the satisfactory removal efficiency of the overall purification process applied in the waterworks and, in particular, of the sand filtration step.

Antibodies↗

Determination of carbaryl in natural water samples by a surface plasmon resonance flow-through immunosensor.

The analysis of carbaryl in natural water samples was accomplished using a portable immunosensor based on surface plasmon resonance (SPR) technology. The assay was based on a binding inhibition immunoassay format with the analyte derivative covalently immobilized on the sensor surface. An alkanethiol self-assembled monolayer (SAM) was formed onto the gold-coated sensor surface to allow the reusability of the same sensing surface during 220 regeneration cycles. Reproducibility was evaluated by performing three independent assays in triplicate on 3 different days. The batch-assay variability was also calculated using three different gold-coated sensor surfaces. The intra- and inter-day relative standard deviation were 8.6 and 15.3%, respectively, whilst a variation of 7.4% in assay sensitivity was obtained by employing different sensor chips. The lowest detection limit, calculated as the concentration providing a 10% decrease of the blank signal, was of 1.38 microg L(-1). Matrix effects were also evaluated in different water types, showing I50 values (carbaryl concentrations that produced a 50% decrease of the blank signal) within the range of carbaryl standard curves in distilled water (2.78-3.55 microg L(-1)). The carbaryl immunoassay performance was validated with respect to conventional high-performance liquid chromatography-mass spectrometry (HPLC-MS). The correlation between methods was in good agreement (r2 = 0.998, 0.999 and 0.999) for the three types of natural water samples tested. A complete assay cycle, including regeneration, is accomplished in 20 min. All measurements were carried out with the SPR sensor system (beta-SPR) commercialised by the company SENSIA, SL (Spain). The small size and low-time of response of the beta-SPR platform would allow its utilization in real contaminated locations.

Biosensing Techniques↗

Determination of nonylphenol and octylphenol in paper by microwave-assisted extraction coupled to headspace solid-phase microextraction and gas chromatography-mass spectrometry.

A novel and simple method for the determination of active endocrine disrupter compounds (octylphenol OP, and nonylphenol NP) in paper using microwave-assisted extraction (MAE) and headspace solid-phase microextraction, coupled with gas chromatography-mass spectrometry has been developed. Parameters affecting the efficiency in the MAE process such as exposure time and extraction solvent were studied in order to determine operating conditions. The optimised method was linear over the range studied (1.25-125 microg kg(-1) for OP and 9.50-950 microg kg(-1) for NP) and showed good level of precision, with a RSD lower than 10% and detection limits at 0.10 and 4.56 microg kg(-1) for OP and NP, respectively. The results obtained from six different types of paper revealed the presence of the target compounds in all samples analysed, at levels ranging between 3 and 211 microg kg(-1).

Calibration↗

Monitoring and toxicity of sulfonated derivatives of benzene and naphthalene in municipal sewage treatment plants.

Monitoring benzenesulfonates (BS) and naphthalenesulfonates (NS) took place in five municipal sewage treatment plants (STP). A previously optimized method based on solid phase extraction with polymeric cartridges followed by ion-pair liquid chromatography-electrospray-mass spectrometry (SPE-IPC-ESI-MS) was used. This work confirmed the little or no effect of primary settlement on total organic carbon (TOC) and monosulfonated compounds removal, whereas the main reduction is obtained at the biological stage. However, the most polar compounds, such as naphthalenedisulfonates (NDS), were not effectively removed using the biological treatment. An aromatic sulfonated compound is suggested to be used as a tracer of the origin of industrial pollutants discharged into STPs. A bioluminescence inhibition test, Microtox assay, allowed toxicity determination of the most relevant aromatic sulfonated compounds detected and toxicity comparison between primary and secondary effluents.

Benzenesulfonates↗

Development of a liquid chromatography-electrospray mass spectrometric method for the simultaneous analysis of benzoxazolinones and their degradation products.

A new method for the simultaneous analysis of some benzoxazolinones, aminophenoxazinones and malonamic acids was developed based on liquid chromatography (LC) coupled to mass spectrometry (MS), using electrospray ionization (ESI) and operating in positive mode. Different ESI-MS parameters, such as fragmentor voltage, capillary voltage, drying gas flow, nebulizer gas pressure and drying gas temperature, were optimized in order to obtain structural information and to achieve maximum sensitivity. Chromatographic separation was performed by a reversed-phase LC column using a linear gradient of water and methanol. Quality assurance of the developed method was assessed by measuring parameters as linearity, sensitivity, repeatability and reproducibility. Quantification method based on the use of internal standard was developed, selecting synthetic 2-methoxy-2H-1,4-benzoxazin-3(4H)-one as internal standard. Good correlations were obtained for all analytes relative to this compound in the range of 0.05-1.5 ng/microL. Instrumental detection limits were between 0.02 and 0.2 ng/microL. Repeatability and reproducibility studies showed acceptable coefficient of variation values.

Benzoxazoles↗

First European interlaboratory study of the analysis of benzoxazinone derivatives in plants by liquid chromatography.

Six laboratories from four different countries participated in the first European interlaboratory comparison exercise within the framework of the "Fate and toxicity of allelochemicals (natural plant toxins) in relation to environment and consumer" (FATEALLCHEM) European Union Project. The study, organized between November 2002 and March 2003, involved the analyses of seven benzoxazinone derivatives in two standard solutions and one purified extract of root material. Results are reported from the first phase of the study that examined the variability associated with different detection methods and different laboratories. The analytical strategies were based on liquid chromatography (LC) with diode array detection, LC coupled to mass spectrometry (MS) and LC coupled to tandem MS. When data from all laboratories were pooled, the relative standard deviation values ranged from 2 to 14% for the determination of target compounds in standard solutions, and between 19 and 47% for the analysis in root material. Comparison of the three detection techniques leads to the conclusion that MS approaches are the most accurate and precise techniques for the determination of benzoxazinone derivatives at ng/microL level in plant material.

Benzoxazines↗

Analysis by liquid chromatography-electrospray ionization tandem mass spectrometry and acute toxicity evaluation for beta-blockers and lipid-regulating agents in wastewater samples.

This paper describes a multiresidue method for the extraction and determination of two therapeutic groups of pharmaceuticals, lipid-regulating agents (clofibric acid, bezafibrate, gemfibrocil, fenofibrate) and beta-blockers (atenolol, sotalol, metoprolol, betaxolol) in waters by solid-phase extraction followed by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS). Recoveries obtained from spiked HPLC water, as well as, from spiked real samples (sewage treatment plants influent and effluents, river and tap water) were all above 60%, with the exception of betaxolol with a 52% recovery. The quantitative MS analysis was performed using a multiple reaction monitoring. The LC-MS-MS method gave detection limits ranging from 0.017 to 1.25 microg/l in spiked effluent. Precision of the method, calculated as relative standard deviation, ranged from 3.7 to 18.5%. Individual and combined effects on Daphnia magna were evaluated for both therapeutic groups. Individual effects in culture medium showed these compounds as not harmful and not toxic, an exception is fenofibrate that was found to be harmful, but at high, in the environment unrealistic concentrations (EC50 of 50 mg/l). Combined effect in wastewater showed synergistic toxic effects at low concentration level (2 microg/l).

Adrenergic beta-Antagonists↗

Simultaneous multi-analyte determination of estrone, isoproturon and atrazine in natural waters by the RIver ANAlyser (RIANA), an optical immunosensor.

In most medical and environmental applications of biosensors, only single analytes are determined. However, the monitoring of several analytes is obviously preferable in order to gather more information about the sample under analysis. In line with this, different technologies are being developed to obtain multi-analyte sensors. In this paper, an analytical method for the simultaneous determination of three different contaminants-atrazine, isoproturon, and estrone-in natural waters by using an optical immunosensor prototype, the so-called "RIver ANAlyser" (RIANA), is described. RIANA is based on a rapid solid-phase fluoroimmunoassay that takes place at an optical transducer chip. The transducer surface is chemically modified with three analytes derivatives placed in different discrete locations. The sensor surface can be regenerated thus allowing the performance of several measurements with the same transducer. Each test cycle, including one regeneration step, is accomplished in 15 min. Detection limits achieved were 0.155, 0.046, and 0.084 microg/l, for atrazine, isoproturon, and estrone, respectively. Satisfactory repetition, with relative standard deviations between 1.06 and 6.98%, was obtained. Excluding a minor non-specifical binding of the isoproturon antibodies, no cross-reactivity effects were observed. Matrix effects were significant only in the case of wastewater samples. Biosensor measurements were validated using conventional liquid chromatography-mass spectrometry. The results obtained with both techniques were in good agreement.

Atrazine↗

LC-MS-(MS) determination of oxidative degradation products of nonylphenol ethoxylates, carboxylates and nonylphenols in water.

A commercial blend of nonylphenol ethoxylates (NPEOs) was chosen as representative for non-ionic polyethoxylated surfactants to study the oxidative degradation of this class of surfactants in water using ozonation as well as electron beam irradiation with and without the addition of ozone as treatment processes. The electron beam irradiation processes applied represent so-called Advanced Oxidation Processes (AOPs); the combined ozone/electron beam irradiation is, moreover, the most powerful AOP which can be applied in aqueous systems. It was found that both ozonation and the two AOPs applied were able to decompose not only the NPEOs but also the polyethyleneglycoles (PEGs) formed as by-products from NPEO degradation to residual concentrations below the limit of detection. Moreover, the treatment processes were also used to study the oxidative degradation of nonylphenoxy acetic acid (NPEC) and of nonylphenol (NP) which are formed as by-products from biodegradation of NPEOs.

Biodegradation, Environmental↗