PubMed Health⌕ Search

Biomedical subjects

D Beysens

Publications and source records attributed to D Beysens.

At least 19 recordsLinked to original sources

Gas spreading on a heated wall wetted by liquid.

This study deals with a simple pure fluid whose temperature is slightly below its critical temperature and whose density is nearly critical, so that the gas and liquid phases coexist. Under equilibrium conditions, such a liquid completely wets the container wall and the gas phase is always separated from the solid by a wetting film. We report a striking change in the shape of the gas-liquid interface influenced by heating under weightlessness where the gas phase spreads over a hot solid surface showing an apparent contact angle larger than 90 degrees. We show that the two-phase fluid is very sensitive to the differential vapor recoil force and give an explanation that uses this nonequilibrium effect. We also show how these experiments help to understand the boiling crisis, an important technological problem in high-power boiling heat exchange.

Journal Article↗

Thermalization of a two-phase fluid in low gravity: heat transferred from cold to Hot

We present an experimental study of the thermal response to a positive temperature quench in two-phase fluid SF6 in low gravity for temperature ranging from 10.1 to 0.1 K from the critical temperature. The temperature was measured simultaneously in the gas, the liquid, and the cell wall by thermistors and the density distribution was observed by interferometry. During the quench the gas temperature considerably exceeded the temperature of the heating walls (overheating up to 23%). This striking observation is discussed in the light of the adiabatic heat transfer in this highly compressible fluid while the key role of the localization in low gravity of the gas and liquid phases is revealed.

Journal Article↗

Magnetic compensation of gravity forces in (p-) hydrogen near its critical point: application to weightless conditions

We report a study concerning the compensation of gravity forces in two-phase (p-) hydrogen. The sample is placed near one end of the vertical z axis of a superconducting coil, where there is a near-uniform magnetic field gradient. A variable effective gravity level g can thus be applied to the two-phase fluid system. The vanishing behavior of the capillary length l(C) at the critical point is compensated by a decrease in g and l(C) is kept much smaller than the cell dimension. For g ranging from 1 to 0.25 times Earth's gravity (modulus g(0)) we compare the actual shape of the meniscus to the expected shape in a homogeneous gravity field. We determine l(C) in a wide range of reduced temperature tau=(T(C)-T)/T(C)=[10(-4)-0.02] from a fit of the meniscus shape. The data are in agreement with previous measurements further from T(C) performed in n-H2 under Earth's gravity. The effective gravity is homogeneous within 10(-2)g(0) for a 3 mm diameter and 2 mm thickness sample and is in good agreement with the computed one, validating the use of the apparatus as a variable gravity facility. In the vicinity of the levitation point (where magnetic forces exactly compensate Earth's gravity), the computed axial component of the acceleration is found to be quadratic in z, whereas its radial component is proportional to the distance to the axis, which explains the gas-liquid patterns observed near the critical point.

Journal Article↗

Viscosity and elasticity during collagen assembly in vitro: relevance to matrix-driven translocation.

In order to better understand the gelation process associated with collagen assembly, and the mechanism of the in vitro morphogenetic phenomenon of "matrix-driven translocation" [S.A. Newman et al. (1985) Science, 228, 885-889], the viscosity and elastic modulus of assembling collagen matrices in the presence and absence of polystyrene latex beads was investigated. Viscosity measurements at very low shear rates (0.016-0.0549 s(-1)) were performed over a range of temperatures (6.9-11.5 degrees C) in a Couette viscometer. A magnetic levitation sphere rheometer was used to measure the shear elastic modulus of the assembling matrices during the late phase of the gelation process. Gelation was detected by the rapid increase in viscosity that occurred after a lag time tL that varied between O and approximately 500 s. After a rise in viscosity that occurred over an additional approximately 500 s, the collagen matrix was characterized by an elastic modulus of the order of several Pa. The lag time of the assembly process was relatively insensitive to differences in shear rate within the variability of the sample preparation, but was inversely proportional to the time the sample spent on ice before being raised to the test temperature, for test temperatures > 9 degrees C. This suggests that structures important for fibrillogenesis are capable of forming at 0 degrees C. The time dependence of the gelation process is well-described by an exponential law with a rate constant K approximately 0.1 s(-1). Significantly, K was consistently larger in collagen preparations that contained cell-sized polystyrene beads. From these results, along with prior information on effective surface tension differences of bead-containing and bead-lacking collagen matrices, we conclude that changes in matrix organization contributing to matrix-driven translocation are initiated during the lag phase of fibrillogenesis when the viscosity is < or = 0.1 Poise. The phenomenon may make use of small differentials in viscosity and/or elasticity, resulting from the interaction of the beads with the assembling matrix. These properties are well described by standard models of concentrated solutions.

Animals↗