PubMed Health⌕ Search

Biomedical subjects

D Bixio

Publications and source records attributed to D Bixio.

At least 19 recordsLinked to original sources

Estimating costs and benefits of advanced control for wastewater treatment plants--the MAgIC methodology.

This paper discusses a methodology to estimate the costs and benefits of advanced control for wastewater treatment plants. The methodology has been applied to four wastewater treatment plants, representing four standard types of plants built in Flanders, Belgium. The paper outlines the methodology and illustrated results from one of the four design cases. General results are shown and contrasted with full-scale experience. The methodology appears to give realistic results and will be used for further refinement of default control algorithms for certain types of plants. A preliminary analysis indicates that on-line control can become cost-effective for plant sizes above 50,000 population equivalents.

Automation↗

Assessment of WWTP design and upgrade options: balancing costs and risks of standards' exceedance.

Numerical models can be used to evaluate design and upgrade scenarios of urban wastewater systems on the basis of their ecological consequences. The objective of this paper is to illustrate a systematic procedure of system design/upgrade. This procedure consists of the following steps: (1) data collection and data reconstruction; (2) model building and calibration; (3) evaluation of scenarios; (4) uncertainty assessment. In contrast to conventional practice, this approach allows to choose the most appropriate trade-off between cost of measures and risk of non-compliance with regulatory limits. An example of its application dealing with the assessment of WWTP design and upgrade options is provided. Results show that by reducing the tank volumes compared to conventional design procedures, costs can be reduced sensibly while the risk of not meeting legislative requirements are only slightly increased.

Cities↗

Benchmarking of WWTP design by assessing costs, effluent quality and process variability.

Process choice and dimensioning of WWTPs is a particularly sensitive step to cost-efficiently comply with regulatory standards. This step accounts only for a small fraction of the upfront costs, but it can lead to substantial savings. This paper illustrates the results of a systematic methodology to evaluate system design/upgrade options. In contrast to conventional practice, this approach allows the choice between the most appropriate trade-off between cost of measures and effluent quality, and to assess the reliability of a process layout. It is therefore a flexible instrument to cope with the flexibility and complexity of integrated water management regulations. Results show good agreement of the simulations with extensiv benchmarking studies on actual plants. For that reason, the suggested methodology can provide valuable support also to such practices.

Benchmarking↗

Experience with phosphorus removal and sludge handling and disposal in Flanders.

The way excess sludge must be disposed of is a key factor in the choice of the appropriate phosphorus removal technique at municipal wastewater treatment plants. In Europe the ongoing trend of tightening the sludge spreading rules called for a serious reduction of its agricultural utilisation and the expansion of the (co-)incineration disposal route, which led to a shift towards more sophisticated sludge handling techniques. This paper illustrates the impact of different sludge handling techniques on the performance of chemical and enhanced biological phosphorus removal at municipal WWTPs. The main conclusion is that although enhanced biological phosphorus removal is particularly sensitive to the problem of return liquors from sludge treatment processes indirect dewatering and anaerobic stabilisation cannot be discarded altogether when considering its implementation.

Bacteria, Anaerobic↗

Technical-economical evaluation of the operation of oxidation ditches.

The optimisation of the economic performance is a central aspect in the management of wastewater treatment plants. A model-based procedure was developed that could provide a clearly enunciated and concise way of reporting to the stakeholders on how well the assets are performing and can perform, separating the firm inefficiency from the effect of the treatment. The applied modelling method is conventional considering current modelling research practice, but very good from practical point of view in that it is applicable utilising existing plant data, i.e. without the use of additional measuring campaigns. This paper illustrates the validity of the developed procedures through the evaluation of the performance of oxidation ditches.

Benchmarking↗

Biological solution to storm water?

Standard practice in Flanders is to limit the hydraulic capacity of sewage treatment works to 6Q14 (Q14= 1.7 dry weather flow Q(DWF)). A maximum of 3Q14 is treated biologically, while the excess flow undergoes only physical treatment in storm tanks. This practice has been challenged by a new high-flow activated sludge operation concept, consisting of the treatment of the full storm sewage flow in the biological train and of the use of the storm tanks as additional secondary clarifiers. After successful testing in two installations, 56 works of different sizes and types were switched to high-flow activated sludge operation from 1999 to 2002. This paper reports on progress and experiences gained since then. The analysis focuses on the parameters subject to regulatory discharge (BOD, COD, suspended solids, total nitrogen and total phosphorus) plus ammonia. Special attention is paid to the performance of the clarification and of the nitrification processes. The results indicate that high-flow biological treatment provides a substantial reduction in wet weather discharges while maintaining acceptable process operating conditions.

Ammonia↗

The inhibitory effects of heavy metals and organic compounds on the net maximum specific growth rate of the autotrophic biomass in activated sludge.

A respirometry technique can be applied as an effective method to determine the net maximum specific growth rate of autotrophic biomass under both normal conditions and when inhibition occurs. The net maximum specific growth rate of uninhibited autotrophic biomass, expressed as (mu(A)-b(A)), is approximately 0.8 per day [Proceeding of the International Congress on CHISA, Prague, 2002, p. 1]. Several heavy metals and organic compounds have inhibitory effects. Copper (Cu(2+)) has stronger inhibitory effects than zinc (Zn(2+)), and inhibits the nitrification process by 50% at 0.08 mg/l [(mu(A)-b(A)) = 0.4 per day], while the same concentration of Zn(2+) establishes 12% inhibition only [(mu(A)-b(A)) = 0.75 per day]. Inhibition with Cu(2+) starts at concentrations above 0.05 mg/l, while this is above 0.3mg/l for Zn(2+). The inhibition of the nitrification process is complete at 1.2mg/l for both Cu(2+) and Zn(2+). Among the selected organic compounds tested n the experiments, the degree of inhibition decreases as follow: chlorobenzene>trichloroethylene (TCE)>phenol>ethylbenzene. Chlorobenzene already inhibits the autotrophic biomass at 0.25 mg/l. The nitrification process is totally inhibited by adding 0.75 mg/l of chlorobenzene. TCE has a less inhibitory effect on the nitrification process and 50% inhibition is noticed at 0.75 mg/l TCE. The nitrification process is totally inhibited at 1mg/l TCE. Phenol inhibits the nitrification for 50% at 3 mg/l. The inhibitory effect of phenol is almost constant in the range 4-10 mg/l and complete inhibition is reached at 50 mg/l. The inhibitory effect of ethylbenzene is 50% at 8 mg/l and the autotrophic biomass is totally inhibited at 50 mg/l. Experimental findings are compared with literature data, which generally and significantly overestimate the inhibition threshold concentrations.

Bacteria↗

Feasibility of automatic chemicals dosage control--a full-scale evaluation.

This contribution discusses the feasibility of automatic control for chemicals dosing in activated sludge systems. The evaluation is made on the basis of a full-scale implementation at the Lommel WWTP (Belgium) of an on-line controlled dosage system for iron chloride and external carbon source. The control laws are very simple and allow intuitive adaptation by the plant operators. The control system results in a significant reduction of the chemicals dosage, better effluent results and a lower sludge production. The implementation is furthermore cost-efficient.

Automation↗

A quantitative risk analysis tool for design/simulation of wastewater treatment plants.

Uncertainty is a central concept in the decision-making process, especially when dealing with biological systems subject to large natural variations. In the design of activated sludge systems, a conventional approach in dealing with uncertainty is implicitly translating it into above-normal safety factors, which in some cases may even increase the capital investments by an order of magnitude. To obviate this problem, an alternative design approach explicitly incorporating uncertainty is herein proposed. A probabilistic Monte Carlo engine is coupled to deterministic wastewater treatment plant (WWTP) models. The paper provides a description of the approach and a demonstration of the general adequacy of the method. The procedure is examined in an upgrade of a conventional WWTP towards stricter effluent standards on nutrients. The results suggest that the procedure can support the decision-making process under uncertainty conditions and that it can enhance the likelihood of meeting effluent standards without entailing above-normal capital investments. The analysis led to reducing the capital investment by 43%, producing savings of more than 1.2 million euro.

Computer Simulation↗

Two years of full-scale storm operation experience.

Current practice in Flanders is to limit the hydraulic capacity of the wastewater treatment plant to 6O14 (O14 = 1.7 dry weather flow O(DWF)). A maximum of 3O14 is treated in the biological system, the excess flow undergoing only physical treatment in the stormtank. This practice has been challenged by a new concept, consisting of the treatment of the full storm sewage flow in the biological train and of the use of the stormtank(s) as additional secondary clarifier(s). This paper reports on the long-term experience gained on a total of 12 full-scale plants. The analysis focused on the parameters subject to regulatory discharge (BOD, COD, suspended solids, total nitrogen and total phosphorus) plus ammonia. Special attention is paid to the performance of the clarification and of the nitrification processes. The significance of the proposed way of operation in attenuating the overall pollution impact on the receiving water body is shown.

Models, Theoretical↗

Impact of cold and dilute sewage on pre-fermentation--a case study.

The municipal sewage treatment plant (STP) of the city of Ghent (Belgium) has to be retrofitted to a 43%-increase in the nitrogen treatment capacity and to phosphorus removal. Cold weather, dilute sewage and a critical COD over N ratio make the retrofit a challenge for full biological nutrient removal. The potential for fermentation of primary sludge to alter those critical feed sewage characteristics was experimentally evaluated. The idea was that the pinpoint introduction of fermentate could optimise the available reactors by achieving high-rate denitrification and enhanced biological phosphorus removal. The fermentation process was evaluated with a bench scale apparatus. At 20 degrees C (heated process), the hydrolysis yield--expressed in terms of soluble COD--varied from 11% to 24% of the total sludge COD. The fermentation yield expressed in VFA COD varied from 8% to 13% of the total sludge COD. The efficiency of heated fermentation of primary sludge was lower during cold and wet weather, due to the different sewage characteristics, as a result of extended dilution periods and low temperature. The raw sewage, the primary effluent and the fermentate were fractionated according to the requirements for the IAWQ Activated Sludge Model No. 2d. The results clearly show that fermentation in the sewer played an important role and temperature was the driving parameter for the characteristics of the dissolved COD. Instead, the weather flow conditions were the driving parameter for the characteristics of the suspended COD. The results of the detailed fractionation were used as background for process evaluation. The final scenario choice for the retrofit depends on a cost-efficiency calculation.

Belgium↗

Full-scale application of the IAWQ ASM No. 2d model.

In the framework of the EU-funded TTP-UPM project (Technology Transfer Project--Urban Pollution Management) the waste water treatment plant (WWTP) of Tielt was modelled with the recently issued IAWQ ASM No. 2d model. Up to 41 % of the total COD load is originating from a textile industry. A measurement campaign was conducted during a period with industrial discharge and a period with only domestic sewage. The stop of the industrial discharge resulted in a highly dynamic response of the system. Based on an expert-approach the calibration was obtained changing only four parameters (anaerobic hydrolysis reduction factor etafe, reduction factor for denitrification etaNO3, the decay rate of autotrophs bAUT and the decay rate of the bio-P organism building blocks bPAO, bPHA, bPP). Influent fractionation remains a critical step within the model calibration. A proven procedure to characterise the influent determinants by standard physical chemical analysis failed to assess the influent COD fractions when the textile waste water is discharged to the WWTP. Selected bench-scale experiments, instead, succeeded in providing the adequate influent characterisation accuracy. For characterising the readily biodegradable COD fraction respirometry is to be preferred.

Bacteria, Anaerobic↗

Renovation of the WWTP hove.

The provision of reliable treatment has always been a priority in sanitary engineering. However, there is an ever-increasing pressure to meet desirable standards at reduced costs. This paper sets out a methodology to enhance the likelihood of a satisfactory allocation of the resources while providing reliable treatment. The procedure was gradually developed to optimise the massive capital investment of the Flemish Government to comply with the effluent standards set in the EU Directive 271/91. The methodology makes an extended use of dynamic modelling. To facilitate the identification and estimation of the uncertainty, a probabilistic Monte Carlo engine is coupled to the dynamic models. In doing so this approach provides a way of explicitly incorporating uncertainty and variability in the process analysis. The procedure is examined in an upgrade of a conventional WWTP towards stricter effluent norms on nutrients. The results suggest that the procedure can support the decision-making process under uncertainty conditions and enhance the likelihood of meeting effluent standards not entailing above-normal capital investments. The analysis led to reducing the capital investment by 43%, producing savings of more than 1.2 million Euros.

Belgium↗