PubMed Health⌕ Search

Biomedical subjects

D Borrey

Publications and source records attributed to D Borrey.

5 recordsLinked to original sources

Longitudinal study on the prevalence of benzodiazepine (mis)use in a prison: importance of the analytical strategy.

AIMS: This study evaluates the suitability of gas chromatographic-mass spectrometric (GC-MS) analysis to follow-up the extent of benzodiazepine (mis)use in a Belgian prison population and compares it to other analytical strategies (e.g. screening followed by confirmation of the positive samples). DESIGN AND PARTICIPANTS: From February to August 1998, 598 persons were jailed of which 188 (31.4% of the incoming detainees) volunteered to be screened. Urine samples (530 in total) were collected on the day of arrival and after 14, 30 and 90 days of imprisonment. MEASUREMENTS: All samples were screened by EMIT(R) for benzodiazepines and analysed subsequently by GC-MS. FINDINGS: EMIT(R) screening yielded 117 (22.1%) positive samples, a number which increased to 174 (32.8%) after GC-MS analysis. Of these 174 GC-MS positive samples, 119 (68.4%) contained one benzodiazepine while for the remaining samples multiple benzodiazepine (mis)use could be demonstrated. A significant increase in benzodiazepine (mis)use was indicated only from day 0 to day 14 based on the GC-MS results but not on the immunoassay results, even when the latter were complemented with GC-MS analysis of the positively screened samples. The GC-MS data also demonstrated that benzodiazepines are mainly (mis)used by subjects on benzodiazepine prescription as almost 50% of these subjects took additional non-prescribed benzodiazepines. During GC-MS analysis other drugs were co-extracted unintentionally and chromatographed and 23.9% of the volunteers were positive for illegal drugs on the day of arrival. CONCLUSION: Immunoassay results yield an underestimation of the problem of benzodiazepine (mis)use in prison due to the high false negative rate. GC-MS analysis of all samples therefore is the recommended strategy for this type of longitudinal study as it yields more correct and detailed information than the immunoassay results.

Belgium↗

Simultaneous determination of fifteen low-dosed benzodiazepines in human urine by solid-phase extraction and gas chromatography-mass spectrometry.

A gas chromatographic-mass spectrometric method was developed for the simultaneous analysis of 15 low-dosed benzodiazepines, both parent compounds and their corresponding metabolites, in human urine. The target compounds are alprazolam, alpha-hydroxyalprazolam, 4-hydroxyalprazolam, flunitrazepam, 7-aminoflunitrazepam, desmethylflunitrazepam, flurazepam, hydroxyethylflurazepam, nitrogen-desalkylflurazepam, ketazolam, oxazepam, lormetazepam, lorazepam, triazolam and alpha-hydroxytriazolam. Nitrogen-methylclonazepam is used as the internal standard. The urine sample preparation involves enzymatic hydrolysis of the conjugated metabolites with Helix pomatia beta-glucuronidase for 1 h at 56 degrees C followed by solid-phase extraction on a phenyl-type column. The extracted benzodiazepines are subsequently analyzed on a polydimethylsiloxane column using on-column injection to enhance sensitivity. The extraction efficiency exceeded 80% for all compounds except for oxazepam, lorazepam and 4-hydroxyalprazolam which had recoveries of about 60%. The LODs ranged from 13 to 30 ng/ml in the scan mode and from 1.0 to 1.7 ng/ml in the selected ion monitoring (SIM) mode. Linear calibration curves were obtained in the concentration ranges from 50 to 1000 ng/ml in the scan mode and from 5 to 100 ng/ml in the SIM mode. The within-day and day-to-day relative standard deviations at three different concentrations never exceeded 15%.

Benzodiazepines↗

Sensitive gas chromatographic--mass spectrometric screening of acetylated benzodiazepines.

GC-MS screening conditions were developed for 15 low-dosed benzodiazepines, covering alprazolam, flunitrazepam, flurazepam, ketazolam, lorazepam and triazolam, and the corresponding metabolites alpha-hydroxyalprazolam, 4-hydroxyalprazolam; 7-aminoflunitrazepam, desmethylflunitrazepam, 7-aminodesmethylflunitrazepam; hydroxyethylflurazepam, N-desalkylflurazepam; oxazepam and alpha-hydroxytriazolam, respectively. Benzodiazepines are analyzed on a polydimethylsiloxane column in both the scan and the multiple ion monitoring modes using on-column injection to attain maximal sensitivity. The reactive compounds are acetylated with pyridine and acetic anhydride for 20 min. The derivatives are stable for at least 4 days. The relative standard deviation observed with standard compounds at the low nanogram-level ranged from 1.13 to 4.87% within-day and from 1.12 to 4.94% between-day. Unequivocal identification potential, high chromatographic resolution and sensitivity are combined with minimal thermal degradation. The presented screening conditions provide the basis for a unique routine screening method for low-dosed benzodiazepines with a broad polarity range.

Acetylation↗

Analysis of fenthion in postmortem samples by HPLC with diode-array detection and GC-MS using solid-phase extraction.

Fenthion (O,O-dimethyl-O-[3-methyl-4-(methylthio)-phenyl]-thiophos-phate ) is an organophosphate insecticide. A specific method to quantitate fenthion in postmortem matrices with solid-phase extraction combined with high-performance liquid chromatography-diode-array detection (HPLC-DAD) and gas chromatography-mass spectrometry (GC-MS) is presented. Fenitrothion (O,O-dimethyl-O-[3-methyl-4-nitrophenyl]-thiophosphate) is selected as the internal standard. For sample cleanup, a simple but selective solid-phase extraction is chosen after comparison with traditional liquid-liquid extraction procedures. Homogenized and appropriately diluted aqueous samples are applied, and the analytes are desorbed with 5 mL of dichloromethane. Aliquots of the extract are used for HPLC-DAD and GC-MS analysis, Liquid and GC conditions are as follows: gradient elution with a mixture of methanol and water (10:90 to 90:10, v/v) containing 0.0125M NaOH on an Aluspher RP-Select B column monitoring at 250 nm, and temperature programming from 60 to 300 degrees C on a dimethylpolysiloxane column in the SCAN mode, respectively. This method is applied to a suicidal case involving unsuspected acute intoxication with fenthion (concentration in blood, 3.8 micrograms/mL).

Aged↗

Analysis of flecainide and two metabolites in biological specimens by HPLC: application to a fatal intoxication.

A few days after her admittance to a hospital for a suicide attempt with benzodiazepines, a 15-year-old girl was found dead in bed. At autopsy, no specific anatomo-pathologic cause of death was identified. Systematic toxicological analysis (HPLC-DAD, GC-NPD, and GC-MS) of postmortem blood and urine revealed the presence of high concentrations of flecainide and its two major metabolites. Flecainide is a class IC anti-arrhythmic drug causing a decreased intracardiac conduction velocity in all parts of the heart. To identify and quantitate flecainide together with its metabolites in blood, urine, and other toxicologically relevant matrices, a new method was developed using high-performance liquid chromatography with diode-array detection. All compounds were separated on a Hypersil BDS phenyl column using water, methanol, and 1.5M ammonium acetate in a gradient system. Chromatographic analysis was preceded by an optimized solid-phase extraction procedure on RP-C18 extraction columns. The flecainide concentrations in blood and urine were 18.73 and 28.3 mg/L, respectively, and the metabolites were detected only in urine at the following concentrations: 9.4 mg/L for meta-O-dealkylated flecainide and 8.59 mg/L for meta-O-dealkylated flecainide lactam. Based on these results, it was concluded that the suicide was consistent with an overdose of this anti-arrhythmic drug.

Adolescent↗