PubMed Health⌕ Search

Biomedical subjects

D Bua

Publications and source records attributed to D Bua.

2 recordsLinked to original sources

Elevated soluble MUC1 levels and decreased anti-MUC1 antibody levels in patients with multiple myeloma.

Soluble MUC1 (sMUC1) levels are elevated in many MUC1(+) cancers. We and others have shown that MUC1 is expressed on multiple myeloma (MM) plasma cells and B cells. In this study, we measured sMUC1 levels in bone marrow (BM) plasma from 71 MM patients and 21 healthy donors (HDs), and in peripheral blood (PB) plasma from 42 MM patients and 13 HDs using an immunoassay that detects the CA27.29 epitope of MUC1. sMUC1 levels were found to be significantly greater (mean 31.76 U/mL, range 5.69 to 142.48 U/mL) in MM patient BM plasma versus HD BM plasma (mean 9.68 U/mL, range 0.65 to 39.83 U/mL) (P <. 001). Importantly, BM plasma sMUC1 levels were related to tumor burden because sMUC1 levels were significantly higher for MM patients with active disease (34.62 U/mL, range 5.69 to 142.48 U/mL) versus MM patients with minimal residual disease (16.16 U/mL, range 5.7 to 56.68 U/mL) (P =.0026). sMUC1 levels were also elevated in the PB plasma of MM patients (32.79 U/mL, range 4.15 to 148.84 U/mL) versus HDs (18.47 U/mL, range 8.84 to 42.49) (P =.0052). Lastly, circulating immunglobulin M (IgM) and IgG antibodies to MUC1 were measured in 114 MM patients and 31 HDs, because natural antibodies to MUC1 have been detected in patients with other MUC1-bearing malignancies. These studies demonstrated lower levels of circulating IgM (P <.001) and IgG (P =.078) antibodies to MUC1 in MM patients compared with HDs. Our data therefore show that in MM patients, sMUC1 levels are elevated and correlate with disease burden, whereas anti-MUC1 antibody levels are decreased.

Autoantibodies↗

Burn depth estimation using indocyanine green fluorescence.

Expedient primary excision of deep dermal and full-thickness burn wounds with subsequent skin grafting is the standard of care in most burn institutions, but differentiating full-thickness from partial-thickness burns is often difficult. Because accurate early assessment of burn depth may improve care, a variety of technical methods have attempted to measure burn depth but these methods have had limited success. We describe a new technique to determine burn depth that uses infrared (840- to 850-nm) fluorescence emission from intravenously administered indocyanine green following excitation with infrared (780 nm) and UV light (369 nm). Full-thickness and partial-thickness burns in hairless rat skin were distinguished based on the infrared-induced and UV-induced fluorescence intensity ratios relative to normal, unburned skin immediately after the burn and on post-burn days 1 through 3 and 7. Dual-wavelength excitation of indocyanine green infrared fluorescence can delineate full-thickness from partial-thickness burns at an early date, allowing prognosis, surgical planning, and early primary excision and grafting.

Animals↗