Biomedical subjects
D Burford
Publications and source records attributed to D Burford.
Localisation of a novel region of recurrent amplification in follicular lymphoma to an approximately 6.8 Mb region of 13q32-33.
Follicular lymphoma (FL) is characterised by the presence of the t(14;18)(q32;q21) and represents approximately 25% of new cases of non-Hodgkin's lymphoma. While the t(14;18) is a well-documented rearrangement, the role of secondary cytogenetic abnormalities in the development and progression of these tumours remains unclear. Comparative genomic hybridisation was used to characterise changes in DNA copy number in tumour DNA from patients with this malignancy. The mean numbers of deletion and amplification events found in each of the 45 samples studied were 1.8 and 2.3, respectively. Regions of recurrent (>10% tumour samples) gain involved chromosomes 2p13-16 (16%), 7 (20%), 12 (16%), 13q21-33 (18%), 18 (27%), and X (36%) and frequent losses localised to 6q (29%) and 17p (20%). Amplification of chromosome 13 represents a novel finding in FL. The minimal amplified region was refined to a 6.8-Mb interval of 13q32-33 between the BAC clones 88K16 and 44H20 by fluorescence in situ hybridisation studies using metaphase chromosomes derived from tumour material. There are a number of reports in the literature suggesting that amplification of chromosome 13 also occurs in other human cancers. The location of the putative oncogene on 13q described here in follicular and transformed lymphoma may also be important in the evolution of many other malignancies.
The BSSO M.Orth Prize of the Royal College of Surgeons of England 1999. British Society for the Study of Orthodontics.
This paper describes the clinical orthodontic treatment of two cases that were awarded the British Orthodontic Society Membership in Orthodontics Prize.
Enamel microabrasion.
Explore the source record for details and available documents.
Skin disease affecting the conservation of the western swamp tortoise (Pseudemydura umbrina)
OBJECTIVE: To review the present position of the western swamp tortoise (Pseudemydura umbrina) as an endangered species and significant health issues affecting efforts to save it from extinction. PROCEDURE: A retrospective analysis of the husbandry, hospital and pathology records of the western swamp tortoise captive breeding program at Perth Zoo. RESULTS: In 1987 a captive breeding project was developed to prevent the extinction of the western swamp tortoise but an outbreak of a necrotising dermatitis in 1989 threatened the survival of the captive bred hatchlings. Less severe outbreaks occurred in 1990 and 1993, with isolated cases in between. Of 283 tortoises that were born in captivity or came into captivity from the wild, 37 (13.1%) were affected, comprising 37% of all males, 26% of all females and 13% of animals of unknown gender. Of the affected animals, 70% were less than 2 years of age and 29% were older. Males were 1.6 times more likely to be infected than females but this difference was not statistically significant (P = 0.27). Culture of the lesions consistently yielded unidentified Pseudomonas sp. CONCLUSION: Improved husbandry, such as strict maintenance of water quality and temperature conditions similar to that of the animal's natural habitat, and monitoring the health of individual tortoises have successfully controlled skin disease in the captive breeding of the western swamp tortoise.
A risk assessment of multiple use of an aerosol system compared with single use for lung ventilation scans.
Over 300 99Tc(m)-DTPA aerosol lung ventilation scans are performed at Leicester Royal Infirmary each year. Current practice is to re-use the nebulizer circuits up to five times over a maximum of 1 week. Following a visit from the hospital infection control team, this practice was questioned and, therefore, a risk assessment was carried out. This compared the risks of multiple use of ventilation circuits with single use. A survey was also carried out to try and establish current practice in other departments. The risk assesment showed that both single and multiple use of nebulizer circuits can have a high risk. The risks associated with the former were radiation safety and/or financial, and the risk with the latter was cross-infection. The survey showed that multiple use is certainly common practice within the UK. Therefore, in coming to a decision on which practice to adopt, these risks must be considered most carefully in the context of the local environment.