Characterisation of the haemodynamics of the superior mesenteric artery.

In contrast to its prevalence in the surrounding vasculature, occurrence of primary atherosclerotic disease in the superior mesenteric artery (SMA) is rare (Glagov et al., 1988. Hemodynamics and atherosclerosis, Insights and perspectives gained from studies of human arteries. Archives of Pathology and Laboratory Medicine 112(10), 1018-1031; Hansen et al., 2004. Mesenteric artery disease in the elderly. Journal of Vascular Surgery 40(1), 45-52). We hypothesise that this sparing might be attributed to more favourable haemodynamic characteristics in the SMA than in other vessels locally. Dynamic magnetic resonance imaging (MRI) images established that the SMA is highly mobile (Jeays, 2006. Investigation of blood flow in the superior mesenteric artery and its potential influence on atheroma and gut ischaemia. Ph.D. Thesis, University of Sheffield), and thus that an analysis based on rigid geometry might be inappropriate. This paper describes an efficient methodology for the construction of a patient-specific, time-dependent model of an arterial segment and reports the results of a haemodynamic characterisation of the SMA for one individual. A transient computational fluid dynamic (CFD) model was constructed by morphing a parametric mesh constructed from simple geometric primitives. This process has the merit that it is easy to control the element size distribution mapped onto the original geometric primitives. It is robust in operation, and is ideally suited to the generation of dynamic CFD meshes of arterial systems that are free from major pathology. Flow boundary conditions were determined based on phase contrast MRI velocity measurements. Comparative studies with rigid walls and with moving walls, based on the transient data, indicated that, despite the significant motion of the SMA (radial dilation of the order of 10% and translation of the order of the radius), the maximum (spatially and temporally-resolved) wall shear stresses changed by no more than 21.6% of a global norm, and the average change was less than 2.1%.

Hemorheology↗

Towards magnetic detection electrical impedance tomography: data acquisition and image reconstruction of current density in phantoms and in vivo.

The objective of magnetic detection electrical impedance tomography (MD-EIT) is to reconstruct in vivo images of conductivity from magnetic field measurements taken around the body. MD-EIT is performed by applying an alternating current, at one of a range of frequencies, to a conducting object through a pair of electrodes fixed to the surface of the object. Magnetic field measurements recorded by search coils at a number of positions around the object are used to determine the current distribution that is generating the magnetic field. From this distribution, a conductivity map of a cross-section of the object can be reconstructed. This paper describes the development of an MD-EIT data acquisition system and discusses the related image reconstruction issues. The ill-conditioned nature of the inverse problem is examined and a number of image reconstruction methods are compared. The technical feasibility of MD-EIT data collection and image reconstruction is demonstrated with example images of current density from both phantom and human data.

Algorithms↗

A method of generalized projections (MGP) ghost correction algorithm for interleaved EPI.

Investigations into the method of generalized projections (MGP) as a ghost correction method for interleaved EPI are described. The technique is image-based and does not require additional reference scans. The algorithm was found to be more effective if a priori knowledge was incorporated to reduce the degrees of freedom, by modeling the ghosting as arising from a small number of phase offsets. In simulations with phase variation between consecutive shots for n-interleaved echo planar imaging (EPI), ghost reduction was achieved for n = 2 only. With no phase variation between shots, ghost reduction was obtained with n up to 16. Incorporating a relaxation parameter was found to improve convergence. Dependence of convergence on the region of support was also investigated. A fully automatic version of the method was developed, using results from the simulations. When tested on in vivo 2-, 16-, and 32-interleaved spin-echo EPI data, the method achieved deghosting and image restoration close to that obtained by both reference scan and odd/even filter correction, although some residual artifacts remained.

Algorithms↗

Image-based EPI ghost correction using an algorithm based on projection onto convex sets (POCS).

This work describes the use of a method, based on the projection onto convex sets (POCS) algorithm, for reduction of the N/2 ghost in echo-planar imaging (EPI). In this method, ghosts outside the parent image are set to zero and a model k-space is obtained from the Fourier transform (FT) of the resulting image. The zeroth- and first-order phase corrections for each line of the original k-space are estimated by comparison with the corresponding line in the model k-space. To overcome problems of phase wrapping, the first-order phase corrections for the lines of the original k-space are estimated by registration with the corresponding lines in the model k-space. It is shown that applying these corrections will result in a reduction of the ghost, and that iterating the process will result in a convergence towards an image in which the ghost is minimized. The method is tested on spin-echo EPI data. The results show that the method is robust and remarkably effective, reducing the N/2 ghost to a level nearly comparable to that achieved with reference scans.

Algorithms↗

Automatic image registration of diagnostic and radiotherapy treatment planning CT head images.

PURPOSE: Accurate image registration is an essential step to integrate information from diagnostic and radiotherapy treatment planning (RTP) CT images. In this paper a fully automatic algorithm is presented to quickly register such diagnostic and RTP CT head scans. METHODS AND MATERIALS: The registration algorithm, which regards one image as the moved version of the other, was applied to seven clinically obtained diagnostic and RTP CT data set pairs. During the RTP scan patients were in treatment position and wearing mold masks. Hence, patient position differed strongly in both image sets. Registrations were inspected visually and compared with results obtained minimizing the sum-of-square difference. RESULTS: Registrations were accurate upon visual inspection. Differences between the two algorithms were at subvoxel level. All cases were successfully registered, using several different starting points. Registration calculations took 1-2 minutes. Minimization of the sum-of-square difference took 1-1.5 hours. CONCLUSIONS: The results show that a fast and accurate image registration is achieved without prior segmentation or feature extraction and that the algorithm is robust, which makes it clinically applicable.

Algorithms↗

Magnetic impedance tomography.

Tissue can be characterized by its electrical impedance, especially if measurement can be extended over a range of frequencies. Recently, there has been a great deal of interest in imaging the distribution of electrical impedance through the technique of electrical impedance tomography (EIT). However, EIT has a number of practical problems relating to the placement of electrodes on the body. Such contacts are not required to collect magnetic field data around an object through which current is flowing and thus this approach may be more practical than EIT in the clinical environment. This paper describes the technique of magnetic impedance tomography (MIT), which allows reconstruction of the current distribution from magnetic field measurements. The reconstruction techniques used to generate the images and the prototype data collection system are described. Images produced using data collected from discrete and distributed current phantoms and the thorax during human respiration are presented.

Electric Impedance↗

Incorporating a priori anatomical information into image reconstruction in electrical impedance tomography.

Image reconstruction in electrical impedance tomography using the sensitivity theorem is generally based on the assumption that the initial conductivity distribution of the body being imaged is uniform. The technique of image reconstruction using this method is described and reconstructed images are presented. Improvements in image quality and accuracy are demonstrated when accurate a priori 'anatomical' information, in the form of a model of the distribution of conductivity within the region to be imaged, is used to construct the sensitivity matrix. In practice correct a priori information is not available, for example the conductivity values within the various anatomical regions will not be known. An iterative algorithm is presented which allows the conductivity parameters of the a priori model to be determined during reconstruction.

Anatomy↗

The use of image registration in the analysis of bone scans for the assessment of temporomandibular joint uptake.

Bone scanning is a commonly used technique in the assessment of patients with facial asymmetry. Uptake in the temporomandibular joints can be assessed quantitatively, either as a right-to-left ratio or as the uptake in the joint relative to some other bony structure. We used image registration techniques in the development of an automatic method of quantitative analysis and compared this with a manual region of interest method. Both image warping and region warping were studied. Normal ranges were established in a series of 25 subjects with no evidence of temporomandibular disorder. The results of this study indicate that, by using image registration and standard regions of interest, the results from normal subjects show a smaller standard deviation and improved correlation between observers when compared with manual analysis.

Adolescent↗

Use of forward projection to correct patient motion during SPECT imaging.

We have developed an iterative method to correct axial and tangential patient motion occurring during tomographic acquisition. The method uses axial images reconstructed from the uncorrected projection images, which are then forward projected to form a basis for registering the original planar images and, in the process, directly seeks to establish a consistent data set. Our method can be applied to all SPECT scans including myocardial and brain SPECT. We demonstrate that the method is capable of detecting and quantitatively correcting for complex motion in both axial and tangential directions. Results from phantom experiments show excellent resolution and contrast recovery after simulated movement in both the axial and tangential directions and initial results with clinical data sets are encouraging.

Biophysical Phenomena↗

Automatic motion correction in dynamic radionuclide renography using image registration.

Time-activity curves from dynamic renograms can be analysed to yield important quantitative parameters. However, accurate results are dependent on curves being free from artefacts caused by patient movement. We describe a method to correct for both translational and rotational motion during renography. The method is image-based and does not require markers. Sequential dynamic frames are registered using an affine transform from which rotational and translational components are extracted by singular-value decomposition. Computer simulations demonstrate correction to < 1 pixel and < 1 degree. The method is also fast, with renograms comprising 75 frames of 64 x 64 pixels taking under 1 min for correction on a Sun SPARC 5.

Automation↗

Three-dimensional electrical impedance tomography.

The electrical resistivity of mammalian tissues varies widely and is correlated with physiological function. Electrical impedance tomography (EIT) can be used to probe such variations in vivo, and offers a non-invasive means of imaging the internal conductivity distribution of the human body. But the computational complexity of EIT has severe practical limitations, and previous work has been restricted to considering image reconstruction as an essentially two-dimensional problem. This simplification can limit significantly the imaging capabilities of EIT, as the electric currents used to determine the conductivity variations will not in general be confined to a two-dimensional plane. A few studies have attempted three-dimensional EIT image reconstruction, but have not yet succeeded in generating images of a quality suitable for clinical applications. Here we report the development of a three-dimensional EIT system with greatly improved imaging capabilities, which combines our 64-electrode data-collection apparatus with customized matrix inversion techniques. Our results demonstrate the practical potential of EIT for clinical applications, such as lung or brain imaging and diagnostic screening.

Algorithms↗

Parametric modelling for electrical impedance spectroscopy system.

Three parametric modelling approaches based on the Cole-Cole model are introduced. Comparison between modelling only the real part and modelling both the real and imaginary parts is carried out by simulations, in which random and systematic noise are considered, respectively. The results of modelling the in vitro data collected from sheep are given to reach the conclusions.

Animals↗

Three-dimensional image reconstruction for electrical impedance tomography.

Very little work has been conducted on three-dimensional aspects of electrical impedance tomography (EIT), partly due to the increased computational complexity over the two-dimensional aspects of EIT. Nevertheless, extending EIT to three-dimensional data acquisition and image reconstruction may afford significant advantages such as an increase in the size of the independent data set and improved spatial resolution. However, considerable challenges are associated with the software aspects of three-dimensional EIT systems due to the requirement for accurate three-dimensional forward problem modelling and the derivation of three-dimensional image reconstruction algorithms. This paper outlines the work performed to date to derive a three-dimensional image reconstruction algorithm for EIT based on the inversion of the sensitivity matrix approach for a finite right circular cylinder. A comparison in terms of the singular-value spectra and the singular vectors between the sensitivity matrices for a three-dimensional cylinder and a two-dimensional disc has been performed. This comparison shows that the three-dimensional image reconstruction algorithm recruits more central information at lower condition numbers than the two-dimensional image reconstruction algorithm.

Algorithms↗

Automatic registration of SPECT images as an alternative to immobilization in neuroactivation studies.

Subtraction of the two components (baseline and stimulation) of a neuroactivation study using 99Tcm HMPAO SPECT requires accurate registration of the two images. Immobilization of the subject during and between the two components of the study can prove difficult and degrades signal to noise ratio. The use of an automated image registration technique for registering the two components of the test can, even in the case where the subject is removed from the scanner, produce significantly better registration than immobilization.

Algorithms↗

A fast parametric modelling algorithm with the Powell method.

This paper presents a model that comprises only two parameters (R/S, fr) and the application of three function minimization algorithms (simplex, Powell and modified Powell) to this model to obtain parametric images. Comparisons among the three algorithms in terms of efficiency and reliability were carried out. It was found that, with proper initialization by taking the shape of the modelled data into consideration, the minimization function can be approximated by a quadratic function near the minimum point, therefore the iteration times can be minimized in the modified Powell method. The results show that with the modified Powell method a substantial reduction of computation time can be achieved in the parametric imaging. This makes it possible to obtain a 16 x 16 parametric image in 1 s.

Algorithms↗

Incorporating a priori information into the Sheffield filtered backprojection algorithm.

The Sheffield image reconstruction algorithm is based on the assumption that the initial conductivity distribution of the body being imaged is uniform. In many situations this assumption is violated. Previous attempts at incorporating a priori information by modifications to the backprojection matrices were ineffective. An alternative method of including a priori information became apparent following the recent reformulation of the Sheffield image reconstruction algorithm. Applying matrix algebra to the image reconstruction equations reveals that the incorporation of a priori information can be considered as either a modification to the original backprojection matrix or a component of a composite data filter. A simple two-dimensional model of the adult head was chosen to test this approach. The results of imaging studies using synthetic data derived from this model show that a priori information has been successfully incorporated into the image reconstruction process. The ability to include a priori information into the image reconstruction process may have significant implications for the more challenging applications of EIT such as imaging the adult head.

Adult↗

Multi-frequency imaging and modelling of respiratory related electrical impedance changes.

Two studies concerning multi-frequency impedance measurements are presented. The first uses tetrapolar measurements made on the thorax and the second electrical impedance tomography images, also made from the thorax. The way in which the impedance and the changes in impedance with ventilation depend upon frequency are investigated using Cole-Cole modelling and also a physiological model of lung tissue. There is an excellent fit to the Cole-Cole model, and the results show that it should be possible to identify tissue on the basis of the impedance spectrum and the spectrum of the changes in impedance during breathing.

Cardiography, Impedance↗