Assessment of abnormal systolic intraventricular flow patterns by Doppler imaging in patients with left ventricular dyssynergy.

Few data exist regarding the consequences of abnormalities of segmental contraction on intraventricular flow patterns. The development of color Doppler flow imaging has now permitted the visualization of intraventricular blood flow patterns. Therefore, we performed Doppler flow mapping in 41 patients (12 with normal left ventricular contraction, eight with hypokinesis or akinesis, and 21 with dyskinesis) and compared these findings with left ventriculography. Systolic blood flow by Doppler mapping in subjects with normal ventricular contraction was characterized primarily by flow through the left ventricular outflow tract and into the aorta. In patients with dyskinesis, paradoxical systolic flow toward the abnormal segment was present, and persisted for at least 50% of systole in 18 of 21 patients. Mean duration of paradoxical flow in dyskinetic patients was 77% of systole. Paradoxical flow was also observed in two of five patients with akinesis but in no patients with hypokinesis. A good correlation was observed between the duration of paradoxical systolic flow and indexes of regional wall motion (radian shortening of the involved myocardium) (r = 0.77) and global ejection fraction derived from cineangiography (r = 0.79). Correlations between the area of the paradoxical systolic flow stream in midsystole and indexes of left ventricular function were less close, with r equaling 0.57 for both regional wall motion and ejection fraction. Thus, paradoxical systolic flow can be detected in most patients with left ventricular dyskinesis, and correlates with the magnitude of regional and global left ventricular dysfunction by cineangiography.

Adult↗

A new thrombolytic regimen for acute myocardial infarction using combination half dose tissue-type plasminogen activator with full dose streptokinase: a pilot study. KAMIT Study Group.

Because a previous study utilizing a combination of recombinant tissue-type plasminogen activator (rt-PA) and urokinase demonstrated reduced reocclusion rates compared with rates obtained with rt-PA alone, this study was conducted to determine whether the combination of rt-PA and streptokinase might achieve similar results at reduced cost. Forty patients with acute myocardial infarction were treated with a 1 h infusion of rt-PA (50 mg) and streptokinase (1.5 million U) administered within 6 h (mean 3.6 +/- 1.2) of symptom onset. Emergency coronary arteriography revealed patency of the infarct-related artery in 30 (75%) of 40 patients. With the addition of coronary angioplasty in those who had unsuccessful thrombolytic reperfusion, the early patency rate was increased to 98%. In-hospital mortality rate (2.5%) and the incidence of significant bleeding requiring transfusion (15%) were low. Angiographically documented reocclusion of the infarct vessel occurred in 3 (8%) of 37 patients by day 7. Regional wall motion of the infarct zone improved by 0.9 +/- 0.9 SD/chord (p less than 0.0005), and ejection fraction increased 3.6 +/- 8% units (p less than 0.05) between immediate and day 7 studies. In contrast to the price of full dose rt-PA ($2,300) or rt-PA with urokinase ($3,500), the cost of this regimen was $1,230. This pilot study demonstrates that at half the cost, a combination of half dose rt-PA with full dose streptokinase offers high infarct vessel patency, recovery of ventricular function, a low rate of reocclusion and few bleeding complications.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Left ventricular distensibility and passive elastic stiffness in atrial septal defect.

Diminished left ventricular distensibility has been postulated as a cause of left ventricular failure in atrial septal defect. To evaluate this hypothesis the indexes of left ventricular compliance and stiffness were estimated in 15 patients with atrial septal defect and the results compared with those in 10 normal subjects. Age, peak left ventricular systolic pressure, end-diastolic pressure, ejection fraction and cardiac index did not differ significantly between groups. Left ventricular end-diastolic volume for the atrial septal defect group was significantly less than that for the control group (mean +/- SD, 61 +/- 9 ml/m2 versus 73 +/- 13, p less than 0.05) in keeping with previous studies. The slope of the log pressure-volume relation was significantly greater in the group with atrial septal defect than in the normal group (0.056 +/- 0.010 versus 0.044 +/- 0.008, p less than 0.01), consistent with increased chamber stiffness. For a group of six patients with atrial septal defect and elevated left ventricular end-diastolic pressure, normalized compliance was significantly less than that in the control group (0.017 +/- 0.001 versus 0.036 +/- 0.007, p less than 0.02). The slope k of the elastic stiffness-stress relation for the total group with atrial septal defect was significantly greater than that of the normal group (21.0 +/- 2.3 versus 18.1 +/- 2.3, p less than 0.01). An index of muscle fiber stretch (dV/VdP x end-diastolic stress x 100) was significantly less in the atrial septal defect group than in the control group (74 +/- 24 versus 106 +/- 22, p less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

fMLP provokes coronary vasoconstriction and myocardial ischemia in rabbits.

Recent pathological studies of coronary arteries from humans with suspected coronary spasm have revealed an augmented intramural burden of inflammatory cells. To test the hypothesis that inappropriate activation of inflammatory cells participates in the evolution of coronary vasospasm, the present experiments employed a newly developed coronary arteriographic technique for use in pentobarbital-anesthetized rabbits to evaluate the coronary vasomotor actions of the nonselective inflammatory cell stimulant, N-formyl-L-methionyl-L-leucyl-L-phenylalanine (fMLP). In 10 of 10 animals, selective left intracoronary injection of 200 ng fMLP evoked profound left coronary narrowing accompanied in all cases by ST segment deviation and dysrhythmias. Thallium-201 scintigraphy demonstrated hypoperfusion of the left ventricular free wall and septum supplied by the spastic coronary artery. The fMLP-induced epicardial vaso-constriction, ischemic electrocardiogram (ECG) changes, and thallium perfusion defects were reversed by intravenous nitroglycerin. Neither the right coronary artery nor its distribution were influenced by left coronary injection of fMLP. Additional experiments in isolated, salt solution-perfused rabbit hearts demonstrated that fMLP failed to exert direct coronary vasoconstrictor effects. These observations indicate that the non-selective inflammatory cell stimulant, fMLP, provokes arteriographically demonstrable coronary spasm with attendant myocardial hypoperfusion and ischemic ECG changes in anesthetized rabbits. Such a model may be useful in exploring the dynamic role of inflammatory cells in development of coronary spasm.

Angiography↗

Comparison of simultaneously performed digital and film-based angiography in assessment of coronary artery disease.

This study compared digital angiography (Digital) to conventional cineangiography (Cine) for the diagnosis and quantification of coronary artery disease. Digital and Cine were obtained simultaneously under identical radiographic conditions during routine coronary arteriography. Using visual inspection and manual calipers, four independent observers identified 131 stenoses in 18 patients with multivessel coronary disease. There was no difference in interobserver variability between Digital and Cine during multiple subgroup analyses. Overall, Digital yielded significantly greater estimates of stenosis severity than did either of two separate Cine observations (p less than 0.0001; average difference, 6.25%), but the differences fell below the level of statistical significance when only the group of stenoses 50% or greater were considered. Digital and Cine correlated well for the assessment of stenosis severity (r = 0.88), but linear regression comparisons of multiple subgroups consistently indicated modest overestimation of Cine by Digital. Smaller vessels, branch vessels, and mild lesions increased the likelihood of overestimation by Digital. Digital was highly sensitive for identification of clinically relevant stenoses, but less specific and less predictive than a second observation of Cine. Our results indicate that Digital and Cine are not interchangeable imaging techniques and that potential differences must be considered when Digital is used for clinical decision making.

Angiography↗

Effect of aortic regurgitation on the assessment of mitral valve orifice area by Doppler pressure half-time in mitral stenosis.

Evaluation of the severity of mitral stenosis by continuous-wave Doppler pressure half-time measurement is now well established. However, few data exist regarding the effect of aortic regurgitation (AR) on the validity of this method. Therefore, 73 patients were studied in whom cardiac catheterization and Doppler echocardiographic examinations were performed. Mitral valve orifice area was determined by the Gorlin equation, 2-dimensional echocardiography and Doppler pressure half-time. Doppler pressure half-time and catheterization estimates of mitral valve area correlated well (r = 0.85) in patients without significant mitral regurgitation. This correlation was maintained in patient subgroups with and without significant (at least 2+) AR (r = 0.86 and 0.83, respectively). Similarly, Doppler and 2-dimensional echocardiographic assessment of mitral valve area showed a strong correlation (r = 0.84). Again, the correlation between the 2 methods was similar in patients with and without significant AR (r = 0.86 and 0.82, respectively). Thus, Doppler pressure half-time estimates of mitral valve orifice area are accurate even in patients with AR.

Adult↗

Determination of left ventricular ejection fraction by computer densitometric analysis of digital subtraction angiography: experimental validation and correlation with area-length methods.

Conventional methods for calculating left ventricular (LV) ejection fraction (EF) require accurate edge definition and geometric assumptions, which may be compromised in the presence of dyssynergy. Computer densitometric analysis (CDA) of digital subtraction angiography offers the potential for calculation of EF, independent of LV shape, by comparing summated brightness for regions of interest at end diastole and end systole. Therefore, the accuracy of CDA was validated for 2 mechanical heart models of differing geometry, spherical and rectangular. Both models confirmed the close correlation between calculated and measured EF (r = 0.98 and r = 0.99, respectively). Subsequently, the CDA was compared with single and biplane area-length EF calculations in 72 patients, half with a previous myocardial infarction. In patients without previous myocardial infarction, CDA correlated closely with both single-plane and biplane EF (r = 0.91 and 0.93, respectively). The close correlation was maintained regardless of whether CDA was applied to direct LV injection or intravenous digital subtraction angiography. However, in 36 patients with previous myocardial infarction, CDA correlated less closely with single-plane (r = 0.74) than with biplane (r = 0.86) area-length EF. Thus, CDA permits calculation of EF without geometric assumptions, and may be superior to the area-length method in patients with LV dyssynergy after myocardial infarction.

Adult↗

Coronary arteriography in the intact rabbit: demonstration of coronary vasomotor and electrocardiographic effects of ergonovine and indomethacin in rabbits after abrupt cessation of prolonged nitroglycerin treatment.

Abrupt withdrawal of chronic nitroglycerin treatment may predispose the coronary circulation to spasm. To test this hypothesis directly, we developed a technique for performing selective coronary arteriography in the intact rabbit with images obtained by video-based methods or cineangiographic film. Experiments were then conducted in rabbits treated three times daily with topical nitroglycerin ointment for 6 weeks and in age- and sex-matched control animals. Forty hours after cessation of treatment, animals were anesthetized, and ECG and coronary vasoactive effects (determined by coronary arteriography) of ergonovine, 0.2 mg/kg (intravenous) and indomethacin, 25 mg/kg (intravenous) were assessed. Of six nitroglycerin-treated rabbits, one died of ventricular fibrillation prior to arteriographic study. The remaining five developed ECG abnormalities (single ventricular premature beats, nonsustained ventricular tachycardia, and ST segment deviation) upon challenge with ergonovine or indomethacin. Neither agent evoked ECG changes in control rabbits. In contrast, the degree of luminal diameter reduction in epicardial coronary arteries provoked by ergonovine or indomethacin did not differ between control and nitroglycerin-treated animals. Focal coronary artery spasm was not observed in any rabbit. Our results demonstrate that selective coronary arteriography in rabbits is feasible and that changes in vessel caliber may be assessed from images thus obtained. Data from this study indicate that ergonovine- and indomethacin-induced ECG abnormalities observed in nitroglycerin-treated rabbits cannot be ascribed to epicardial coronary artery spasm.

Animals↗

Value and limitations of computer analysis of digital subtraction angiography in the assessment of coronary flow reserve.

Conventional coronary angiography has significant limitations in quantifying the severity and functional significance of coronary stenoses. However, coronary reactive hyperemia is an excellent physiologic indicator of coronary reserve. Digital subtraction angiography offers the potential to analyze coronary blood flow dynamics quantitatively. Therefore we assessed the accuracy of digital angiographic methods to detect and quantify reductions in coronary flow reserve secondary to stenoses of varying magnitude in an experimental canine preparation. Studies were performed in nine anesthetized open-chest dogs with an electromagnetic flow (EMF) probe and two pneumatic occluders positioned on the left circumflex coronary artery. One occluder served to induce reactive hyperemia by temporary total occlusion, while the other served to produce variable gradations of stenosis. Digital angiography was performed after the subselective injection of contrast under basal conditions and during reactive hyperemia. Time-intensity curves were obtained from digital angiograms for both a coronary and a myocardial region of interest. Measurements included area under the curve, time to peak contrast, and contrast disappearance rate. An index of coronary reserve was computed as the ratio of hyperemic to basal measurements for each of these methods. Coronary blood flow ranged from 6.5 to 142 ml/min, with hyperemic to basal EMF flow ratios of 0.80 to 4.2:1. The index derived from contrast decay rate showed a poor correlation with EMF (r = .34). The correlation between measurements of time to peak myocardial contrast and coronary blood flow was r = .68 (y = 0.16 x + 0.97). The area under the time-intensity curve from a coronary region of interest showed a close correlation with coronary blood flow (y = 0.91 x + 0.1, r = .86). Thus estimates of coronary reserve by computer analysis of digital subtraction angiograms can yield information regarding the physiologic consequences of coronary stenoses.

Angiography↗

Assessment of the severity of valvular regurgitation by digital subtraction angiography compared to cineangiography.

The purpose of this study was to evaluate whether the degree of valvular regurgitation could be reliably estimated by digital subtraction angiography using a 0 to 4+ scale of measurement identical to that applied in conventional cineangiography. Thirty-seven sets of angiograms, each consisting of a digital subtraction angiogram (DSA) and a cineangiogram (CINE) were obtained from 33 patients. Twenty-three angiogram sets were obtained from the ventricles, while 14 were performed in the ascending aorta. Both DSA and CINE images were analyzed for regurgitation by two independent observers. A weighted kappa statistical analysis, carried out to determine the extent to which the two observers agreed on DSA and CINE assessments, demonstrated excellent agreement. The degree of atrioventricular valve regurgitation manifested by DSA was not significantly different from that determined on CINE for either Observer A or B (1.8 +/- 1.2 by CINE vs 2.1 +/- 1.5 by DSA, 2.1 +/- 1.4 vs 2.5 +/- 1.0, respectively). However, occasional exceptions occurred in which the degree of atrioventricular valve regurgitation was overestimated by DSA as compared to CINE. Conversely, in 12 cases with aortic regurgitation, DSA overestimated the grade of regurgitation compared to CINE, 2.3 +/- 1.1 by CINE vs 3.2 +/- 0.8 by DSA (p less than 0.01) for Observer A and 2.1 +/- 1.2 vs 3.0 +/- 1.0 (p less than 0.01) for Observer B. The phenomenon which best explains these data is the occurrence of digital enhancement of myocardial opacification produced by coronary perfusion radiocontrast during angiography.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Correlation of continuous wave Doppler velocities with cardiac catheterization gradients: an experimental model of aortic stenosis.

The purpose of this study was to use a canine preparation of experimental aortic stenosis to compare estimates of pressure gradient derived from continuous wave Doppler ultrasound with gradients measured directly by catheterization. Aortic stenosis was created in six mongrel dogs by placing an elastic band around the aorta. Eighty-eight different pressure gradients, ranging from 5 to 160 mm Hg, were produced by variable tightening of the aortic band. Pressure gradients were measured by micromanometer-tipped catheters placed in the left ventricle and aorta. Doppler spectral signals were simultaneously obtained using a 2.0 MHz nonimaging transducer placed directly on the surface of the ascending aorta. Doppler and pressure recordings were analyzed using a custom-designed software program to measure maximal instantaneous, mean and peak to peak gradients, as well as ejection and acceleration times. Maximal instantaneous Doppler gradient showed an excellent linear correlation with maximal instantaneous catheterization gradient (r = 0.98, SEE = 5.3 mm Hg). The correlation of Doppler-estimated maximal gradient to peak to peak catheterization gradient was also linear (r = 0.97, SEE = 6.2 mm Hg) but resulted in a systematic overestimation of pressure drop (mean overestimation = 9.0 mm Hg). Measurement of the Doppler gradient at mid-systole resulted in a more accurate correlation with the peak to peak catheterization gradient (r = 0.98, SEE = 6.1 mm Hg) and eliminated the problem of overestimation.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Evaluation of 516 cardiopulmonary resuscitation attempts.

All adult cardiopulmonary resuscitations attended by the pharmacy department at a 486-bed tertiary-care institution were analyzed over a 24-month period. Data describing patient demographics, drug and equipment use, and patient survival were collected on 516 consecutive adult arrests. These data were recorded on a report form by a pharmacy technician and were classified as cardiac, respiratory, trauma, or other. Trauma included arrests caused by motor-vehicle accidents and gunshot wounds, and other included arrests caused by anaphylaxis or seizures. The majority of arrests (70%) were classified as cardiac, 24% as respiratory, and 6% as other. Overall, 54.5% of the patients suffering from arrests were resuscitated successfully. There was an equal distribution of arrests throughout the day. The mean duration of the resuscitation efforts was 38 minutes with a trend toward greater patient survival when resuscitation efforts lasted less than 15 minutes. Arterial blood-gas determinations were made in 81% of the arrests, defibrillations in 40%, and pacemaker or chest tube insertion in less than 10%. Sodium bicarbonate was the most frequently administered medication, followed by calcium salts and atropine sulfate. Lidocaine was used in 83% of the cases requiring antiarrhythmic therapy. Pressor support was required in 44.6% of the cases; norepinephrine bitartrate was the first-line pressor agent. Drugs not categorized as essential according to the American Heart Association's Advanced Cardiac Life Support (ACLS) standards were administered infrequently. Hospitals may benefit from arrest data in assessing their equipment and supply needs, staffing patterns, and personnel training programs.

Evaluation Studies as Topic↗

Multiformity if induced unifocal ventricular premature beats in human subjects: electrocardiographic and angiographic correlations.

Single ventricular premature responses induced by strength-interval pacing were elicited at multiple sites in 30 patients undergoing cardiac catheterization to determine if and under what circumstances unequivocally unifocal stimulated ventricular premature beats could manifest multiformity of the QRS configuration. Multiformity was defined as unifocal responses whose mean frontal axes differed by greater than 15 degrees with or without associated morphologic differences in the horizontal leads. Multiformity occurred in 12 (40 percent) of 30 patients. A statistically significant association was found between multiformity and the presence of a quantitatively defined left ventricle wall motion abnormally (p less than 0.01), prior myocardial infarction (p less than 0.01) and a left ventricular election fraction of less than 0.60 (p less than 0.05). Twelve (67 percent) of the 18 patients without multiformity had coronary artery disease, but only 4 of those 12 had a left ventricular wall motion abnormally or prior myocardial infarction, or both. Multiformity was also dependent on the site of stimulation and on the degree of prematurity. The results of this study indicate that the QRS configuration of early premature beats cannot be relied on as a predictor of their site of origin and multiformity is not necessarily synonymous with multifocality.

Adult↗

T lymphocyte beta 2-adrenergic receptor function and density after acute myocardial infarction.

The T lymphocyte beta 2-adrenergic receptor (beta 2AR) density and function were compared in 15 patients suffering acute myocardial infarction and 10 patients with stable coronary artery disease (CAD). Density was determined using radioligand binding with 125IPIN, and function by in vitro cyclic adenosine 3',5'-monophosphate (cAMP) production. In patients suffering acute myocardial infarction, T lymphocyte beta 2AR density (823.8 +/- 480 sites/cell) was slightly but not significantly different from that in patients with stable CAD (629 +/- 301 sites/cell). There was no difference in T lymphocyte cAMP production at baseline (1.11 +/- 0.70 vs 1.04 +/- 0.49 pM/10(6) cells) or after isoproterenol stimulation (2.53 +/- 1.63 vs 2.62 +/- 2.05 pM/10(6) cells), respectively. Further study is necessary to determine if beta 2AR numbers on T lymphocytes are significantly increased after acute myocardial infarction.

Aged↗