The effect of continuous poly (methyl methacrylate) fibres on some properties of acrylic resin denture base material.

This study investigated the effect of continuous poly (methyl methacrylate) fibres on the transverse strength and impact strength of poly (methyl methacrylate) denture base resin. The fibres were added in three arrangements, a single unidirectional (longitudinal in the length of the specimen) layer, two longitudinal layers and in cross ply form (a combination of an inferior longitudinal layer and a superior transverse layer). The results indicated that the transverse bend and impact strengths of poly (methyl methacrylate) denture base resin, were not significantly improved by the addition of poly (methyl methacrylate) fibres.

Acrylic Resins↗

The reinforcement of dentures.

The material most commonly used for the fabrication of complete dentures is poly (methyl methacrylate) (PMMA). This material is not ideal in every respect and it is the combination of virtues rather than one single desirable property that accounts for its popularity and usage. Despite its popularity in satisfying aesthetic demands it is still far from ideal in fulfilling the mechanical requirements of a prosthesis. The fracture of dentures may be due to the mechanical properties of the acrylic resin or may be due to a multiplicity of factors leading to failure of the denture base material. Generally, there are three routes which have been investigated to improve the impact properties of PMMA: the search for, or development of, an alternative material to PMMA; the chemical modification of PMMA such as by the addition of a rubber graft copolymer; and the reinforcement of PMMA with other materials such as carbon fibres, glass fibres and ultra-high modulus polyethylene. The following review of attempts to improve the mechanical properties of denture base material takes account of papers published during the last 30 years.

Carbon↗

Computer-generated study of the correlation between tooth, face, arch forms, and palatal contour.

STATEMENT OF PROBLEM: Several factors have been suggested as aids for artificial tooth selection. Numerous methods have been devised for the evaluation of reliable esthetic factors in determining artificial tooth form. There is no universally accepted single esthetic factor that can be used reliably to aid artificial tooth selection. PURPOSE: This article describes a new method incorporating a computer program to analyze four esthetic factors: form of the face, arch form, palatal contour, tooth shape, and to determine whether there was correlation between tooth, face, and arch forms and palatal contour. MATERIAL AND METHOD: Impressions were made of the maxillary dentition of 50 dentate undergraduate dental students with irreversible hydrocolloid impression material and casts formed. A standardized photographic procedure was used to record portrait slides of each subject's face and of maxillary dental arches and central incisors made from dental casts. A comprehensive computer program was developed to correlate esthetic factors by superimposition. RESULTS: Superimposing outline form between face, tooth, and arch showed that for tooth to face form nearly half the comparisons were dissimilar and only 22% corresponded. This is the lowest level of correspondence in this group. Highest correspondence (28%) occurred between arch to face form, followed by arch to tooth form (24%). Arch to tooth showed the lowest level of dissimilarity (32%). For correlation among the four factors across the sample group based on a comparison of classifications in each subject, men tended to dominate tapering classes, whereas women dominated square and ovoid classes. CONCLUSION: Correspondence of outline forms through superimposition revealed an insignificant correlation between face, tooth, and arch forms. Although this method applies high technology, it does not improve the accuracy of determining shape and size of teeth in an edentulous patient. The cost and complexity of the method of measurement may also make it impractical for common application.

Adult↗

In at the deep end--an insight into scuba diving and related dental problems for the GDP.

Scuba diving is one of the fastest growing sports in the world. It is inevitable that the general dental practitioner (GDP) will have patients who participate in this sport and they should be aware of a number of problems that a diver can experience that are associated with the teeth and related structures. The aim of this article is to introduce the GDP to the dental problems associated with diving and make recommendations on dental care for scuba divers.

Barotrauma↗

Complete dentures--the soft option. An update for general dental practice.

Permanent soft linings are frequently used as a 'soft option' blanket treatment for problems such as chronic pain under a lower denture, when it would be more appropriate to diagnose and eliminate any possible precipitating factors. The aim of this article is to provide an update on temporary and permanent soft materials and to give guidance on their indications and limitations of use, together with advice on their maintenance.

Dental Impression Technique↗

A combined orthodontic/restorative clinic. Rationale, evolution, and experience.

The rationale for running combined clinics between orthodontics and restorative dentistry is given, together with the history of the development and experience of such a clinic at the Dental School and Hospital in Cardiff. Brief details of the organization of the combined clinic and possible future developments are also given.

Adolescent↗

An in vitro investigation of the abrasive qualities of a selection of denture-cleaning pastes on poly(methyl methacrylate) denture base material.

This study investigated the damage to poly(methyl methacrylate) (PMMA) denture base material caused by brushing with a range of denture-cleaning pastes using an electric, motor-driven, reciprocal-action toothbrushing machine. Plate specimens of PMMA were exposed to 5000, 10,000 and 20,000 brush strokes with four commercial and one recently developed denture-cleaning pastes. Products were applied as slurries in dilutions of 1:2, 1:3 and 1:5. Wear and roughness measurements were made using a surfometer. Results of a one-way analysis of variance showed that there was a statistically significant difference between each of the different denture-cleaning pastes at each given dilution for each number of wear cycles. For the denture-cleaning pastes, doubling the number of brush strokes in most cases, increased the depth of abrasion by a factor of two. A reduction in the Roughness Index and depth of wear was seen, again in most cases, with a dilution from 1:2, 1:3 and to 1:5. A recently developed paste (Blend-a-Dent Hygienic denture paste) bad a comparatively low wear and roughening effect on PMMA denture base material; however, further investigation of its stain-removal properties are necessary before it can be recommended as a suitable denture-cleaning paste.

Analysis of Variance↗

Denture fixatives--an update for general dental practice.

While some clinicians accept that denture fixatives have a valuable function in certain situations and contribute significantly to denture retention and stability, others disapprove of their use, believing that there is no substitute for a properly constructed, accurately fitting denture. It is also believed that their inappropriate use can lead to problems such as impairment of the development of the neuromuscular system which is important for the retention and stability of dentures. However, because these fixatives are available over the counter, it is important that clinicians, whatever their opinion, can give patients informed advice. The aim of this paper, therefore, is to provide an update, advice and recommendations on the use of denture fixatives.

Adhesives↗

DIY dentures--a case report.

Minor self adjustments to dentures is a common finding. This case report describes do-it-yourself major adjustments to a removable prosthesis in an attempt to convert it to a fixed prosthesis and the resultant damage to the dental tissues.

Adult↗

Cross-infection control in dental laboratories.

The attitudes to cross-infection control of 800 dental laboratories registered with the Dental Laboratories Association have been surveyed. Considering the topicality of the subject material and the need for careful cross-infection control within and beyond the dental surgery, the response rate of 22% (175) was disappointingly low. As a result of the low response rate, the results should be seen as a guide only. Forty-nine percent of respondents had a cross-infection policy and of those with no policy 64% intended to implement one in the future. Thirty percent of laboratories receive known undisinfected work from the dental surgery. Of those items disinfected on arrival at the laboratory, those most frequently disinfected are dental impressions (77%) and dentures (51%). The most popular chemicals used for disinfection are household bleach, chlorhexidine and glutaraldehyde. Forty-four percent of the respondents generally (90% or more of the time) wear gloves when handling dental work received and opened in the laboratory. Seventy-four percent wear protective eye spectacles when trimming or polishing prostheses. Sixty-one percent used no disinfectant in the pumice and 93% did not disinfect the polishing instruments, eg wheels and mops. Forty-six percent had a policy for immunisation of staff against Hepatitis B.

Attitude of Health Personnel↗

Denture cleansing--the best approach.

Denture cleanliness is essential to prevent malodour, poor aesthetics and the accumulation of plaque/calculus with its deleterious effects on the mucosa. There are a large number of solutions, pastes and powders available for cleaning dentures with a variety of claims for their relative efficacies. Denture cleansers in common use can broadly be divided into those having mechanical or chemical effects. Surveys show that some denture wearers experience difficulty in cleaning their dentures satisfactorily and many wear dirty dentures. Replacement dentures are sometimes necessary due to general deterioration of the denture base material because of the misuse or abuse of a range of approved denture cleaning methods or do-it-yourself cleaning methods such as the use of household bleach. Current popular cleaning methods used among complete and partial denture wearers are discussed and advice is given on recommended methods of cleaning dentures. The results of a survey conducted to assess patients' knowledge of cleaning procedures and methods and materials used are also presented. Respondents used a variety of combinations of cleaning methods. The findings of this survey that a large number of people do not know how to clean their dentures satisfactorily are in agreement with those of previous surveys. Recommendations are given on suitable methods of cleaning both metal and acrylic resin dentures.

Denture Cleansers↗

An in vitro investigation into the wear effects of selected restorative materials on enamel.

Abrasive wear testing of five restorative materials was carried out with human enamel as the opposing surface using a wear machine specifically designed to simulate the masticatory cycle. The results showed that enamel demonstrated good abrasion resistance against amalgam and microfine composite and moderate abrasion resistance against gold. Conventional composite produced marked destruction of enamel and the greatest amount of enamel wear was produced by porcelain. The ranking order compared favourably with results from in vivo studies.

Bisphenol A-Glycidyl Methacrylate↗

An in vitro investigation into the wear effects of selected restorative materials on dentine.

Wear testing of five restorative materials was carried out against plates of human dentine using a wear machine specifically designed to simulate the masticatory cycle. The results showed that dentine is substantially less wear resistant than enamel when compared to previous findings. Amalgam produced no measurable wear of dentine, conventional composite produced extreme destruction and porcelain produced the greatest amount of wear. Great care should be taken with the choice of restorative material when opposing dentine.

Analysis of Variance↗

An in vitro investigation into the wear effects of unglazed, glazed, and polished porcelain on human enamel.

Abrasive wear tests were performed on unglazed, glazed, and polished porcelain stud specimens using human enamel as the opposing plate specimens. The wear tests were carried out on a wear machine that was specifically designed to simulate the masticatory cycle. The amount of enamel wear produced by both glazed and unglazed porcelain was similar; however, that produced by polished porcelain was substantially less. Investigation of the glazed porcelain surface showed that the glaze was removed in less than 2 hours of wear on the machine.

Dental Enamel↗

An in vitro investigation of a comparison of bond strengths of composite to etched and air-abraded human enamel surfaces.

PURPOSE: The purposes of the study were to measure the tensile bond strength of composite resin to human enamel specimens that had been either etched or air-abraded, and to compare the quality of the marginal seal, through the assessment of microleakage, of composite resin to human enamel specimens that had been either etched or air-abraded. MATERIALS AND METHODS: Thirty mandibular molar teeth were decoronated and sectioned mesio-distally to produce six groups, each containing ten specimens that were embedded in acrylic resin using a jig. In each of the four treatment groups, the specimen surfaces were treated by either abrasion with 27 or 50 microm alumina at 4 mm or 20 mm distance, and a composite resin was bonded to the treated surfaces in a standardized manner. In the two control groups the specimens were treated with 15 seconds exposure to 36% phosphoric acid gel and then similarly treated before being stored in sterile water for 1 week. All specimens were then subjected to tensile bond strength testing at either 1 or 5 mm/min crosshead speed. For the microleakage study, the degree of dye penetration was measured 32 times for each treatment group, using a neutral methylene blue dye at the interface between composite and either 27 or 50 microm air-abraded tooth structure or etched enamel surfaces. RESULTS: The mean bond strength values recorded for Group 1 (phosphoric acid etch, 5 mm/min crosshead speed) was 25.4 MPa; Group 2 (phosphoric acid etch, 1 mm/min), 22.2 MPa; Group 3 (27 microm alumina at 4 mm distance), 16.8 MPa; Group 4 (50 microm alumina at 4 mm distance), 16.9 MPa; Group 5 (27 microm alumina at 20 mm distance), 4.2 MPa; and for Group 6 (50 microm alumina at 20 mm distance) 3.4 MPa. An analysis of variance (ANOVA) demonstrated significant differences among the groups, and a multiple comparison test (Tukey) demonstrated that conventionally etched specimens had a greater bond strength than air-abraded specimen groups. No significant difference in dye penetration could be demonstrated among the groups (p= 0.58). CONCLUSIONS: Composite resin applied to enamel surfaces prepared using an acid etch procedure exhibited higher bond strengths than those prepared with air abrasion technology. The abrasion particle size did not affect the bond strength produced, but the latter was adversely affected by the distance of the air abrasion nozzle from the enamel surface. The crosshead speed of the bond testing apparatus had no effect on the bond strengths recorded. The marginal seal of composite to prepared enamel was unaffected by the method of enamel preparation.

Acid Etching, Dental↗

Methods used to select artificial anterior teeth for the edentulous patient: a historical overview.

PURPOSE: Selecting artificial teeth for a denture is complex when there are no remaining natural teeth and no pre-extraction records. The aim of this paper is to review the methods used to select artificial anterior teeth for the endentulous individual. MATERIALS AND METHODS: The review takes account of the majority of papers published during the last 100 years and is organized according to the methods used for determining artificial tooth form. RESULTS: Several factors have been proposed as aids for artificial tooth selection, and numerous methods have been devised for the evaluation of reliable esthetic factors in determining artificial tooth form. CONCLUSION: To date, no universally reliable method of determining tooth form has been found. The Williams classification (1914) is the most universally accepted method of determining anterior tooth form.

Denture Design↗

The effect of chopped poly(methyl methacrylate) fibers on some properties of acrylic resin denture base material.

PURPOSE: The fracture of acrylic resin dentures remains an unresolved problem. Over the years, various approaches to strengthening acrylic resin have been suggested, including modifying or reinforcing the resin. The aim of this study was to investigate the effect of chopped poly(methyl methacrylate) (PMMA) fibers on some properties of acrylic resin denture base material. MATERIALS AND METHODS: PMMA in the form of fibers 0.75 mm in diameter and 5 mm in length was added to acrylic resin denture base material in various percentages to form a composite material. The influence on doughing and manipulation times and transverse strength was examined. The results were subjected to statistical analysis using a one-way analysis of variance and, where appropriate, the Scheffé test. RESULTS: The results showed that the doughing time was decreased by the addition of fibers, with the manipulation and setting times showing inconsistent changes. There was a significant difference between the materials in terms of the transverse strength. When the amount of PMMA fibers in the acrylic resin was increased, there was a decrease in the modulus of rupture and a decrease in the modulus of elasticity. The differences were shown to be statistically significant in some groups. CONCLUSION: The doughing time was decreased by the addition of fibers, while the manipulation and setting times showed inconsistent changes. The incorporation of chopped, randomly oriented PMMA fibers into acrylic resin had no advantage over the unmodified polymer in terms of strength and cannot be recommended as a reinforcing agent for acrylic resin denture base material.

Acrylic Resins↗

Effect of the addition of poly(methyl methacrylate) beads on some properties of acrylic resin.

PURPOSE: There have been numerous attempts to improve the mechanical properties of acrylic resin. However, the fracture of dentures is still an unresolved problem. The potential advantage of self-reinforcement should be improved mechanical properties over the amorphous random polymer. This study investigated the addition of poly(methyl methacrylate) (PMMA) beads in a variety of percentages on a range of mechanical properties of PMMA denture base acrylic resin. MATERIALS AND METHODS: The transverse and impact strengths and hardness of acrylic resin specimens stored in water for periods of 1 week and 6 months prior to testing were investigated. RESULTS: The results showed that for specimens stored for 1 week, the addition of up to 25% beads produced a significant increase in the modulus of elasticity. Addition of 5% beads produced a slight but nonsignificant increase in the modulus of rupture, although additions of increasing percentages produced a decrease in the modulus of rupture. The impact strength was increased for 5% to 25% beads and decreased for 40% beads. The hardness showed only small changes. For specimens stored in water for 6 months, the modulus of rupture decreased with increasing percentages of beads. The addition of beads up to 10% significantly increased the modulus of elasticity. There was no significant increase in impact strength but a significant increase in hardness for 5% beads. CONCLUSION: The addition of PMMA beads to acrylic resin did not produce a substantial improvement in the mechanical properties and cannot be recommended as a method of reinforcement in its present form.

Acrylic Resins↗