PubMed Health⌕ Search

Biomedical subjects

D C Tunc

Publications and source records attributed to D C Tunc.

5 recordsLinked to original sources

In vitro and in vivo degradation of bioabsorbable PLLA spinal fusion cages.

The in vitro and in vivo degradation of poly-L-lactic acid cages used as an adjunct to spinal arthrodesis was investigated. In the in vitro experiments cages were subjected to aging up to 73 weeks in phosphate-buffered solution (pH 7.4) at 37 degrees C. Inherent viscosity, crystallinity, and mechanical strength were determined at different time points. In the in vivo study, the poly-L-lactic acid cages were packed with bone graft and implanted in the L3-L4 spinal motion segment of 18 Dutch milk goats. At 12, 26, and 52 weeks, the motion segments were isolated and poly-L-lactic acid samples retrieved. On evaluation, the in vivo implanted cages showed an advanced decline in inherent viscosity compared to the cages subjected to in vitro degradation experiments. At 6 months of implantation, the geometrical shape and original height of 10 mm was maintained during 6 months of follow up. This finding fits well with the observation that mechanical strength was maintained for a period of 6 months in vitro. At 12 months, the poly-L-lactic acid cage had been disintegrated into multiple fragments with signs of absorption. Despite the high-load-bearing conditions, the poly-L-lactic acid cage allowed interbody fusion to occur without collapse of the cage.

Absorption↗

Orientruded polylactide based body-absorbable osteosynthesis devices: a short review.

A new process 'orietrusion' has been developed to impart a high degree of molecular orientation into polylactide. Mechanical tests showed that this process increased the initial strength of the high molecular weight polylactide by 690%. Orthopaedic osteosynthesis devices that were made from this oriented polyactide were shown to be biocompatible and body-adsorbable. Screws that were made from this material were shown to be efficacious in canine calcaneous and femoral osteotomy models. The orientruded polylactide screws were shown to be efficacious in the fixation of the human malleolar fractures.

Animals↗

Body-absorbable osteosynthesis devices.

The need for the development of totally body-absorbable internal bone fixation devices has been documented in the literature during recent years. A new process called 'orientrusion' has been developed which has made it possible to increase the strength of the polyactide up to 490 MPa. This material was found to be totally absorbable, and biocompatible. Bone fixation devices made from the orientruded polylactide have been successfully used in the fixation of medial malleolar fractures in humans.

Absorption↗