Diagnostic values of positron emission tomography versus triple-phase bone scan in hip arthroplasty loosening.

INTRODUCTION: The most frequent complications of total hip arthroplasty are septic and aseptic wear-induced loosening. A reliable differentiation between septic and aseptic loosening with current diagnostic tools is not possible. Therefore, we examined the diagnostic valency of positron emission tomography (PET) with (18)F-fluorodeoxyglucose (FDG) in cases of septic or aseptic hip arthroplasty loosening compared with conventional triple-phase bone scan (TPBS). MATERIALS AND METHODS: Fifty patients with 70 total hip replacements (symptomatic n=50, asymptomatic n=20) were examined by means of FDG-PET and TPBS to detect septic and aseptic loosening and differentiate between the two. A differentiated algorithm subdivided into categories I-V was developed for FDG-PET. Additionally, standardized uptake values (SUV) were calculated from the lesion with the highest FDG uptake. Interpretations of the TPBS were done according to the criteria described by Wilson. The final diagnosis was based on operative findings including microbiological and histological examinations (n=50), while the remaining asymptomatic arthroplasties (n=20) were integrated into a clinical follow-up (> or =9 months). RESULTS: Sensitivity/specificity of FDG-PET was 91%/92% (accuracy 91%) compared with 78%/70% (accuracy 74%) for TPBS. A high correlation could be proved between FDG-PET investigation and operative histopathological findings (r(Spear)> or =0.9). No significant differences were found regarding cemented and uncemented implanted hip arthroplasties (p> or =0.05). Calculation of the SUV turned out to be inappropriate as a sole criterion for image interpretation. CONCLUSION: FDG-PET is a promising, highly accurate examination method to detect polyethylene and metal wear-induced chronic inflammation followed by periprosthetic osteolysis. In addition, FDG-PET has a significantly higher sensitivity and specificity than TPBS for differentiating between aseptic loosening and infection.

Adult↗

Radionuclide imaging of the painful hip arthroplasty: positron-emission tomography versus triple-phase bone scanning.

Two major complications of hip replacement are loosening and infection. Reliable differentiation between these pathological processes is difficult since both may be accompanied by similar symptoms. Our aim was to assess the diagnostic ability of triple-phase bone scanning (TPBS) and positron-emission tomography (PET) to detect and differentiate these complications in patients with a hip arthroplasty. Both TPBS and PET were performed in 63 patients (92 prostheses). The radiotracer for PET imaging was (18)F-fluorodeoxyglucose (FDG). Image interpretation was performed according to qualitative and quantitative criteria although the final diagnosis was based upon either surgical findings or clinical follow-up. The sensitivity, specificity and accuracy of PET was 0.94, 0.95 and 0.95 respectively, compared with 0.68, 0.76 and 0.74 for TPBS. We found that an image interpretation based exclusively upon quantitative criteria was inappropriate because of its low selectivity. The histological examination indicated that increased periprosthetic uptake of FDG in patients with aseptic loosening was caused by wear-induced polyethylene particles and the subsequent growth of aggressive granulomatous tissue.

Adult↗

Reactive knee and ankle joint arthritis: abnormal manifestation of Legionella pneumophila.

This case report demonstrates that active legionellosis is not always characterised by pulmonary symptoms and specific radiomorphological findings. Whereas the initial clinical presentation, as described in the literature, includes fever, cough, expectoration, extrapulmonary organ changes or typical laboratory findings, atypical manifestations such as reactive arthritis must be considered.

Adult↗

[FDG PET as an early nuclear medical diagnostic tool for aseptic wear-induced loosening of hip joint endoprostheses--a report of two cases].

To date, 2-[F-18]fluoro-2-deoxy-D-glucose PET (FDG PET) is used as a tool in oncology as well as myocardiological and cerebral functional diagnostics in the clinical routine. False positive results of tumor search imply new possibilities for use in diagnostics of inflammation. The two case reports presented here on aseptic loosening of endoprostheses caused by the rub of polyethylene with histological and immunohistological refurbishing call attention to the possible diagnostic valency of FDG PET as an early warning system regarding aseptic artificial limb loosening induced by the rub of polyethylene. By quantification of glucose metabolism with the "standard uptake value" (SUV) as well as specific storage samples from around the artificial limb, it is the aim of our study group in further examinations to develop an algorithm which permits to distinguish between septic and aseptic loosening.

Acetabulum↗

Aneurysmal bone cyst: value of MR imaging and conventional radiography.

Our objective was to investigate the accuracy and the diagnostic value of different imaging features of primary aneurysmal bone cysts (ABC) in conventional radiographs and MRI. Conventional radiographs and MR images of 34 patients with a suspected aneurysmal bone cyst were reevaluated by six independent radiologists in a blinded fashion. Morphological features, MR signal characteristics, and contrast enhancement patterns were assessed. Diagnoses were correlated with histology. Sensitivity and specificity of the different imaging findings for each imaging technique were calculated. In 24 patients ABC was histologically proven. In 10 cases diagnoses other than ABC were established. Conventional radiography and MRI each demonstrated a sensitivity of 76.4 and 77.8% with a specificity of 55.0 and 66.7%, respectively. With combined use of both imaging modalities sensitivity and specificity increased to 82.6 and 70%, respectively. The ABC was significantly more often seen as circumscribed lesion with bone expansion, lobulation, septa, and pathological cortical bone reaction than those cases with different diagnoses. Septal contrast enhancement proved to be a useful MR imaging finding in suspected ABC. The combined use of conventional radiographs and MRI revealed the highest sensitivity in the diagnosis of ABC in relation to histology. Magnetic resonance imaging provides improved diagnostic specificity and valuable information on soft tissue changes.

Adolescent↗

Use of extracorporeal shock-wave therapy (ESWT) in the treatment of non-unions. A review of the literature.

Presently, extracorporeal shock-wave therapy (ESWT) is not yet a standard therapeutic technique in orthopaedics. The mechanism for the analgesic effect or the effect of shock waves on osseous defects are still unknown. With the help of a review of the literature, indications and success rates for ESWT in the treatment of non-unions are outlined, while adequate impulse and energy rates are defined according to the present state of knowledge. Non-union is defined as an absent healing process after a duration of 6 months. The aim of this study is to rate the published data. A total of 52 papers referring to ESWT of the locomotor system are reviewed, with a focus on the 635 patients from 10 publications who underwent ESWT to treat non-unions. Validation was performed for each paper dealing with this topic according to the internationally accepted system of the American Association of Spine Surgery as types A-E. Conclusions regarding possible applications in therapy were taken only from high-quality publications of types A and B. This advice can be regarded as scientifically as well as economically sound. The investigations concerning non-union hardly live up to scientific standards. No serious complications were observed. Because of the complication rate in operative treatment of non-unions, ESWT seems to be justifiable. The techniques of ESWT, energy density levels and impulse rates will be described. Atrophic non-unions seem to represent a poorer starting point in comparison with hypertrophic non-unions. Most investigations showed a consolidation of the non-union during a period of 3 months following ESWT, so that in case of treatment failure, operative treatment in the form of a re-osteosynthesis would only be delayed for this period of time. The advantages of ESWT are its non-invasiveness and low rate of complications. The primary aim of further research should be the evaluation of adequate energy density levels and impulse rates for various indications in accordance with evidence-based medicine. Long-term results need to become available before ESWT can be compared with established methods.

Animals↗

[Basic research of applying extracorporeal shockwaves on the musculoskeletal system. An assessment of current status].

Detailed knowledge concerning the action of extracorporeal shock waves on the locomotor system as well as concerning possible side effects of extracorporeal shock wave therapy (ESWT) are crucial to optimize the clinical use of ESWT for the treatment of illnesses such as calcific tendinitis of the shoulder, tennis elbow, plantar fasciitis, aseptic pseudarthrosis, and aseptic hip necrosis. This study presents the current knowledge gained from animal experiments, which have yielded important findings, in particular concerning possible side effects of ESWT. Very recent studies have also provided valuable insights into the molecular actions of extracorporeal shock waves on the locomotor system. Further intensified experimental animal research will greatly improve the scientific basis for the clinical use of ESWT in the near future.

Animals↗

[Influence of implant position of a hip prosthesis on alignment exemplified by the CLS shaft].

We performed a clinical and radiological analysis to evaluate the significance of the stem position of cementless CLS components with respect to function and survival. We used patient material from a multi-center study of 3,732 CLS stems with a mean follow-up of 43 months (range: 12-142 months). The clinical outcome was assessed using Merle D'Aubigné Scores and stem alignment was determined as the deviation of the longitudinal stem axis from the longitudinal femur axis. We found no correlation between stem alignment and function, survival, implant migration or periprosthetic radiolucent lines. In patients with rheumatoid arthritis and hip ankylosis the neutral stem position was less often achieved than in patients with other diagnoses. The results of our study cast doubt on whether the varus position of the femoral component of cementless tapered CLS-type stem designs is as critical as in cemented total hip arthroplasty.

Aged↗

[Minaro--new approaches for minimally invasive roentgen image based hip prosthesis revision].

The main objective of the MINARO project (Minimal Invasive NAvigation and RObotics) is the development of a modular intraoperative planning system for fluoroscopy based total hip revision surgery. Especially the distal cement removal can be a challenging problem. To avoid exhaustive x-ray imaging a navigation system should be used, nevertheless, the three-dimensional shape of the bone cement remains unclear. Our approach in the MINARO-project is to reconstruct the real shape of the bone cement by using just a few x-ray projections. First results show, that the reconstruction has an RMS-Error smaller than 0.5 mm using 6 x-ray projections.

Arthroplasty, Replacement, Hip↗

[Technical principles for removal of femoral bone cements in hip prosthesis implant revision].

As the removal of femoral bone cement is one of the most challenging tasks in cemented total Hip Revision, a lot of different technical devices have been developed to aid the surgeon. All of their pros and cons are partly consequences of the specific system-design but mainly arise from the basic physical principles used. The known methods and devices as well as their data-handling have therefore been analysed, reduced to their principles according to the criteria of systematic engineering design and systematized in order to provide a better comparability and starting point for the development of new devices.

Arthroplasty, Replacement, Hip↗

Improvement of the long-term adhesive strength between metal stem and polymethylmethacrylate bone cement by a silica/silane interlayer system.

A loss of adhesive strength between metal stem and bone cement is clinically found to be a serious problem in total hip arthroplasty and causes many operative revisions. The objective of this study was to improve the long-term adhesive strength at this interface. A new silica/silane interlayer coating system is introduced. The layers are designed to bond the metal stem surface to the polymethylmethacrylate bone cement marginally leakage free. In vitro tensile tests were performed on specimens of TiAl6V4 and CoCrMo that were cemented by pairs with different bone cements with and without the new coating system. The specimens were stored in isotonic saline solution up to 150 days. The adhesive strength decreased about 75% within 30 days of storage on specimens of both metal alloys that were conventionally cemented without the new interlayer system. With the new coating, the high initial adhesive strength (40-50 MPa) could be stabilized for TiAl6V4 over 150 days. For the same 150-day storage period, the adhesive strength of the coated CoCrMo alloy still decreased but the decrease was only half that experienced by the uncoated CoCrMo. The loss of adhesive strength on CoCrMo specimens could be reduced if the metal surface was activated by a plasma treatment. The new coating interface system could help to considerably reduce revision operations caused by debonding effects at the interface metal/polymethylmethacrylate bone cement.

Adhesiveness↗

Septic arthritis of the knee in adults: treatment by arthroscopy or arthrotomy.

Fifty-one patients with septic arthritis of the knee were reviewed retrospectively. Twenty-seven patients had been treated by arthroscopic lavage and debridement, 24 patients by open arthrotomy with subtotal synovectomy. The patients were staged according to the duration of preoperative symptoms and to the intraoperative spread of the inflammatory process. With early onset of therapy (less than 5 days) and without osseous involvement arthroscopic treatment led to an effective resolution of infection with better functional results than open arthrotomy.

Adult↗

Material properties of trabecular bone structures.

The transplantation of human allograft for restoration and filling of cortical bone defects is well known. Our aim was an experimental investigation of the mechanical stability of the often used femoral head spongiosa depending on the caliber and extent of the allograft. To evaluate the orientation of the trabecular structures of the femoral head and relate this data to its mechanical properties, morphometric studies were combined with mechanical tests of cancellous bone specimens. The mechanical examination of the allograft was done following the compression test according to DIN 50106. We examined 36 human unfixed hip joint spongiosa cylinders with a height of 11 mm and a diameter of 24 mm. We took three specimens from each femoral head. We compressed the allograft at a constant velocity of 0.017 mm/sec. We calculated the maximum compression strength, the yield point and the Young's modulus. We also examined 12 parallelepipedic specimens with (17 x 17 x 51 mm) for morphometric analysis and loading in the direction of the primary compressive group (PCG), as well as perpendicular loading and at an angle of 45 degrees. We found divergent mechanical stabilities. None of the femoral heads showed comparable compressive strength. There was no position dependency of the strength of the samples. No relation between optical appearance and strength was found. We found a value for the lower compressive strength, which can be used for calculation as a basic value for safe constructions. Furthermore we tested the well known dependence of strength on the direction of the trabecular structure. We found a strong relationship between strength and load direction on the preferred direction of the trabecular structure. The sole recommendation resulting from our investigations is to rely on the lowest compressive strength for all preoperative planning. Relying on higher compressive strength by using the theoretical predicted areas of higher strength is hazardous since we found no correlation between position of sampling and strength. The size of our samples is important, because of the fact that different sizes of the samples might cause different failure mechanisms in the samples. The preparation of the femoral head spongiosa should be done according to the primary compressive group of the trabecular structure.

Aged↗

Cross-sectional imaging patterns of desmoplastic fibroma.

The aim of this study was to work out the cross-sectional imaging characteristics of desmoplastic fibroma (DF). In 3 patients with histologically proven DF, the imaging characteristics obtained with cross-sectional techniques were reviewed retrospectively. Radiographs and CT scans were available in all patients, and plain and contrast-enhanced MR examinations in 2 patients. Compared with conventional radiographs, CT allowed more accurate assessment of the extent of bone destruction including cortical breakthrough and articular invasion. Intramedullary tumor growth and soft tissue extension was best detected with MRI. Apart from heterogeneity on MR images, DF displayed nonspecific low signal intensity on unenhanced T1-weighted images and an intermediate to high signal intensity including areas of low intensity on T2-weighted images. Desmoplastic fibroma showed a distinct, inhomogeneous gadolinium enhancement. Although cross-sectional imaging features of DF are nonspecific, some MR characteristics, such as inhomogeneous contrast enhancement and the presence of low-intensity regions on T2-weighted images, are helpful in determining the differential diagnosis. Cross-sectional imaging of DF is useful for local staging of the tumor because it provides valuable information about the extent of bone destruction as well as medullary and extraosseous spread.

Adolescent↗

[Stretched polyethylene (UHMWPE)--a new substance modification for minimizing wear in artificial knee joint replacement].

Polyethylene wear is a major cause of aseptic loosening of knee endoprostheses. With the aim of minimizing this mechanical wear, we stretch-modified the structure of polyethylene. From plates of UHMWPE, stretched PE samples were produced under defined conditions, and subsequently submitted to friction tests in a fluid environment (cycles 5 x 10(5), frequency 1.5 Hz, load 500 N, contact stress 10 MPa). After load testing, the stretched samples revealed a 70% reduced wear rate in comparison with non-stretched samples. Microscopic examination (light microscopy, scanning electron microscopy) showed abrasive scratches in all test samples, but only in the non-stretched specimens were signs of pitting found. Translating these results to unidirectional tractive rolling on the tibial plateau in the knee joint suggests that a significant reduction in polyethylene wear can be expected. However, further experimental investigations need to be carried out to confirm this highly promising possibility.

Elasticity↗

Spinal stabilization in Duchenne muscular dystrophy: principles of treatment and record of 31 operative treated cases.

The aim of this study was to report results of prophylactic spinal stabilization in patients with Duchenne muscular dystrophy. There is still debate regarding the ideal instrumentation. A prospective study of a consecutive series of 31 patients stabilized with the ISOLA system from D2 to S1 will be presented. The mean follow-up was 22 months (range, 1-60 months). The evaluation of the Cobb angle and pelvic obliquity revealed the following: 1) Cobb angle: preoperation, 48.6 degrees (range, 22-82 degrees); postoperation, 12.5 degrees (range, 0-30 degrees); follow-up, 12.5 degrees (range, 0-42 degrees); and 2) pelvic obliquity: preoperation, 18.2 degrees (range, 3-40 degrees); postoperation, 3.8 degrees (range, 0-13 degrees); follow-up, 5.1 degrees (range, 0-14 degrees). Spinal stabilization with the ISOLA system was found to be a suitable treatment for scoliosis owing to Duchenne muscular dystrophy. It should be carried out after loss of ambulation as soon as a progressive curve of more than 20 degrees is documented. The complication rate was found to be high.

Adolescent↗

A modular femoral implant for uncemented stem revision in THR.

We present the early results of 142 uncemented femoral stem revisions using the modular MRP-Titan system. There were 70 cases with marked preoperative femoral bone defects (Paprosky type 2C and type 3); and bone grafts were used in 31 cases. At a mean follow-up of 2.3 years five cases were re-revised due to dislocation and two due to aseptic loosening. The mean Harris hip score improved from 37.4 preoperatively to 92.4. In 122 cases progressive bone regeneration on X-ray was seen; and no further osteolysis was observed.

Adult↗

Interleukin-6: a potential inflammatory marker after total joint replacement.

In a prospective study C-reactive protein (CRP) and interleukin-6 (IL-6) measurements were taken serially in 30 patients before and after 20 total hip arthroplasties (THR) and 10 total knee arthroplasties (TKR). There were no peri- and postoperative complications. Postoperatively the IL-6 serum concentration increased rapidly and peaked 6 h postoperatively at maximum levels (399+/-140 pg/ml). There was a mean half-life of 15 h and thereafter a rapid return to normal concentrations. In comparison, the postoperative CRP concentration rose more slowly and reached maximum levels (138+/-54 mg/l) on the second postoperative day. There was thereafter a slow descent with a mean half-life of 62 h. There was no significant difference between the patients with THR and those with TKR (P>0.05). IL-6 is therefore a superior marker for the inflammatory phase after THR and TKR.