PubMed Health⌕ Search

Biomedical subjects

D Celleno

Publications and source records attributed to D Celleno.

At least 19 recordsLinked to original sources

Minimum analgesic dose of epidural sufentanil for first-stage labor analgesia: a comparison between spontaneous and prostaglandin-induced labors in nulliparous women.

BACKGROUND: The aim of this prospective, double-blind, sequential allocation study was to compare the effects of spontaneous and prostaglandin-induced labor on the minimum analgesic dose of epidural sufentanil in the first stage of labor. METHODS: Seventy healthy, nulliparous women, at more than 37 weeks' gestation with cervical dilatation from 2 to 4 cm, requesting epidural pain relief in labor were enrolled. The subjects were assigned to two different groups according to whether labor was spontaneous or induced with dinoprostone 0.5 mg. Parturients received 10 ml of the study solution through a lumbar epidural catheter. The initial dose was sufentanil 25 microg, and subsequent doses were determined by the response of the previous patient in the same group using up-down sequential allocation. The analgesic effectiveness was assessed using 100-mm visual analog pain scores. The up-down sequences were analyzed using the method of independent paired reversals and probit regression. RESULTS: The minimum analgesic dose of sufentanil in spontaneous labor was 22.2 microg (95% CI: 19.6, 22.8) and 27.3 microg (95% CI: 23.8, 30.9) in induced labor. The minimum analgesic dose of sufentanil in induced labor was significantly greater (P = 0.0014) than that in spontaneous labor (95% CI difference: 2.9, 9.3) by a factor of 1.3 (95% CI: 1.1, 1.5). CONCLUSION: Prostaglandin induction of labor produces a significantly greater analgesic requirement than does spontaneous labor.

Adult↗

[Levobupivacaine in obstetric analgesia and anaesthesia].

METHODS: Published studies, including abstracts, has been reviewed and summarized. RESULTS: Studies in sheep have demonstrated no significant differences in pharmacokinetic and placental transfer of levobuvacaine when compared with bupivacaine. Clinical studies on cesarean section confirmed similar performance between these two drugs. No differences in onset time, sensory and motor block and efficacy of analgesia have been reported. Two multicentre studies on labor analgesia reported again similar analgesic efficacy with a trend toward less motor block in parturients receiving levobupivacaine. CONCLUSIONS: This review has shown that levobupivacaine has a similar efficacy and a similar maternal fetal safety to that of bupivacaine. Further studies are needed to determine if the chemical properties of the new agent may influence the sensory and motor characteristics of the block.

Analgesia, Obstetrical↗

[Motor block determination for the identification of accidental spinal injection of levobupivacaine: a study on the minimum efficient test-dose (ED50)].

BACKGROUND: The aim of this study was to determine the ED50 for the dose of levobupivacaine 0,5% that, if given intrathecally will not cause total spinal anesthesia but will give a reliable and reproducible clinical sign to differentiate intrathecal from epidural injection. METHODS: Thirty women at term undergoing elective cesarean section under a combined spinal-epidural technique (CSE) were enrolled into this sequential allocation study. The dose in each test dose was determined by the response of the previous patient to the higher or lower dose in her test syringe, according to up-down sequential allocation. The exception to this was the first woman in each group, for whom the starting dose was chosen to be 4 mg. The end point was the occurrence of any motor block, in any side, within 5 minutes from intrathecal injection of the test dose. Test dose efficacy was assessed using a modified Bromage scale every minute for 5 minutes. The median effective dose of levobupivacaine was estimated from the up-down sequences using the formula of Dixon and Massey. RESULTS: The MAD of the test dose for levobupivacaine was of 4,8 mg (4,4 to 5,2; 95% C.I.). DISCUSSIONS: This study may help to determine the appropriate dose for a test dose for inadvertent spinal levobupivacaine.

Anesthesia, Obstetrical↗

[Prehydratation and anaesthesia in obstetrics: state of the art].

All epidural or spinal techniques using local anaesthetics causes some degree of sympathetic blockade resulting in peripheral vasodilatation and possibly hypotension or reduction in cardiac output. In the practical clinic, administration of fluids intravenously prior spinal and epidural anaesthesia is required to prevent maternal hypotension and fetal hypoxia. We evaluated in this review the efficacy of volume preloading on the incidence of hypotension after spinal or epidural anaesthesia for caesarean delivery. Randomized controlled trials investigating volume preloading before the initiation of obstetric anaesthesia were sought by using MEDLINE (1966-2001). The primary outcome was the incidence of hypotension. Secondary outcomes included: ephedrine use, Apgar scores, umbilical cord pH values, and maternal nausea and vomiting. Crystalloid preload was inconsistent in preventing hypotension, whereas colloid appeared to be effective in all studies. A colloid solution, such as hydro-xyethyl starch (HES) might be preferable considering the capacity to stay intravasculary for a longer period. Few differences in fetal outcomes or maternal nausea and vomiting were reported. Increasing central blood volume by using colloid decreases the incidence of hypotension before loco-regional anaesthesia for cesarean delivery. Implications. We performed a review to determine whether fluid loading reduced the incidence of low blood pressure after spinal or epidural anaesthesia for caesarean delivery. Although no technique totally eliminates the occurrence of hypotension, colloid administration (starch or gelatin containing fluids) was the most effective.

Anesthesia, Local↗

SCS in intractable angina.

Despite a wide range of therapeutic choice in the treatment of angina pectoris, there is a small but increasing population of patients that doesn't benefit of conventional therapy and whose life is invalidated by frequent attack of anginal pain. For this population, nonresponders to drug therapy not suitable for revascularization (coronary bypass surgery, angioplasty), neurostimulation of dorsal column has been described as an effective and safe therapy. The mechanism of action is not completely known, but is safety is sufficiently established. It may become a useful choice in the treatment of patients with intractable angina.

Aged↗

Relative potencies of bupivacaine and ropivacaine for analgesia in labour.

We have used the technique of randomized, double-blind sequential allocation to compare the minimum local analgesic concentrations (MLAC) of epidural bupivacaine and ropivacaine for women in the first stage of labour. The test bolus was 20 ml of local anaesthetic solution. The concentration was determined by the response of the previous woman to a higher or lower concentration of local anaesthetic, according to up-down sequential allocation. Efficacy was assessed using a 100-mm visual analogue pain score (VAPS). The test solution had to achieve a VAPS of 10 mm or less to be judged effective. For bupivacaine, MLAC was 0.093 (95% CI 0.076-0.110)% w/v, and for ropivacaine, 0.156 (95% CI 0.136-0.176)%w/v (P < 0.0001, 95% CI difference 0.036-0.090). The analgesic potency of ropivacaine was 0.60 (0.47-0.75) relative to bupivacaine. Claims for reduced toxicity and motor block must be considered with differences in analgesic potency in mind.

Adult↗

Autotransfusion with predeposit-haemodilution and perioperative blood salvage: 20 years of experience. Rizzoli Study Group on Orthopaedic Anesthesia.

BACKGROUND: Through a prospective study, we evaluated the efficacy of an integrated autotransfusion regimen comprised of predeposit-hemodiluition and intra and post-operative blood salvage in major orthopaedic surgery. METHODS: We examined the records of 2303 consecutive patients (1524 females and 779 males, mean age 62.7, standard deviation 11 years (range 16-90 yrs), pre-operative haemoglobin (Hb) concentration 13.5 (SD 1.4) (range 6.7-19.3) g/dl undergong total hip arthroplasty (THA 1582 patients), THA after the removal of internal fixation devices (RFD+THA, 25 patients), total knee arthroplasty (TKA, 347 patients), revision surgery of the hip (HR, cup+stem revision, 248 patients; cup revision 64 patients; stem revision 23 patients) and total knee revision (TKR 14 patients). We estimated that the number of predonations (MSBOS - maximum surgery blood order schedule) was 2 units for THA, TKA and TKR, and 3 units for partial or total hip revision and for total hip arthroplasty with fixation removal. RESULTS: It was possible to obtain the MSBOS in 2070 patients (89.8%). Homologous red blood cell (HRBC) transfusion were carried out in 184 patients (8%). We found that the need to use HRBC was significantly associated with failure to meet the number of MSBOS, female sex, lower pre-operative Hb concentration, use of calcium heparin for antithrombosis prophylaxis, more extensive surgery, a higher ASA rating and co-existing diseases such as coronary artery disease. CONCLUSIONS: Cooperation among anaesthesis, transfusionists and surgeons in the application of an integrated autotransfusion regimen enabled us to treat 92% of our patients with only autotransfusion.

Adolescent↗

Minimum local analgesic concentration of extradural bupivacaine increases with progression of labour.

We have used the technique of double-blind sequential allocation to quantify the minimum local analgesic concentration (MLAC) of extradural bupivacaine for women in early (median cervical dilatation 2 cm) and late (median cervical dilatation 5 cm) labour. The first bolus was 20 ml of the bupivacaine test solution. The concentration was determined by the response of the previous woman to a higher or lower concentration of bupivacaine according to up and down sequential allocation. Efficacy was assessed using a 100-mm visual analogue pain score (VAPS). The test solution had to achieve a VAPS of 10 mm or less to be judged effective. In early labour, the MLAC of bupivacaine was 0.048% w/v (95% confidence intervals (CI) 0.037-0.058% w/v), and 0.140% w/v (95% CI 0.132-0.150% w/v) in the late group. The MLAC of bupivacaine in late labour was greater by a factor of 2.9 (95% CI 2.7-3.2) compared with the MLAC in early labour (P < 0.0001, 95% CI difference 0.08-0.11). We conclude that advancing labour requires an increased concentration of extradural bupivacaine for pain relief.

Adult↗

Alkalinization improves the quality of lidocaine-fentanyl epidural anaesthesia for caesarean section.

This double-blind randomized study of 116 healthy women was undertaken to evaluate whether alkalinization potentiated the analgesic effects of epidural fentanyl-lidocaine for elective Caesarean section. After a test-dose of 3 ml, lidocaine 2% with adrenaline 1:200,000, all patients received 100 micrograms, fentanyl in 5 ml saline and they were then divided into two groups, to receive incremental doses of 5 ml lidocaine 2% with adrenaline 1:200,000 with or without 0.1 mEq.ml-1 sodium bicarbonate, to obtain anaesthesia to T4. The addition of bicarbonate to lidocaine resulted in a mean (SD) pH increase from 6.58 (0.01) to 7.14 (0.02) and in a mean PCO2 increase from 3.8 (0.8) to 345.1 (5.9) mmHg. Onset of sensory analgesia to the S1 segment as well as the interval between the block and the delivery of the baby were shorter in the bicarbonate group (respectively 15.4 (6.9) vs 18.9 (4.8) min and 28.9 (9.5) versus 33.9 (11.8) min; P < 0.01 and 0.05). No differences were noted in the onset to T4 or in the degree of motor block. The percentage of patients experiencing pain during surgery and requiring intravenous analgesics was higher in the group which did not receive bicarbonate (3% vs 16%; P < 0.05). There were no differences in intraoperative maternal side-effects, neonatal outcome or in maternal venous and umbilical venous and arterial lidocaine concentrations between the groups. The concentrations of fentanyl in maternal plasma, umbilical artery, and the umbilical artery to maternal vein ratio were greater in the alkalinized group (P < 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

IV clonidine for post-extradural shivering in parturients: a preliminary study.

We have studied the efficacy of i.v. clonidine to suppress post-extradural shivering in parturients. Forty healthy parturients who received extradural block for labour (n = 20) or for Caesarean section (n = 20) and who required treatment for shivering after delivery were allocated randomly to two groups. Group I received i.v. clonidine 30 micrograms diluted in saline to a total volume of 5 ml (therapeutic solution). This bolus was repeated every 5 min if the initial therapy produced no improvement, up to a maximum dose of 90 micrograms. Group II received saline 5 ml (placebo solution), repeated every 5 min if the initial bolus produced no improvement, up to a maximum of three boluses. After 15 min of observation, patients in group I received the placebo solution and those in group II received the study solution. All patients who received clonidine improved, and 75% ceased to shiver within 5 min after only one dose of clonidine 30 micrograms. In contrast, none of the patients treated with saline improved. When patients in the placebo group received clonidine, improvement occurred. Arterial pressure, heart rate, core and peripheral temperature and oxygen saturation did not differ significantly between and within the groups before and after administration of clonidine. We conclude that a small dose of i.v. clonidine may be useful to suppress post-extradural shivering in parturients.

Anesthesia Recovery Period↗

Ventilatory effects of subarachnoid fentanyl in the elderly.

Twenty-eight elderly patients scheduled for urological surgery were randomly assigned to receive, in a double-blind study, subarachnoid hyperbaric bupivacaine 15 mg with 50 micrograms (group A, n = 7), 25 micrograms (group B, n = 7), or 12.5 micrograms (group C, n = 7) of fentanyl or 1 ml of saline (group D, n = 7) in a total volume of 4 ml. The pattern of breathing and the ventilatory response to CO2 were studied before and 90, 150 and 480 min after the subarachnoid injection. In group A, mild pruritus and sedation occurred in five patients, while nausea, vomiting and periodic breathing occurred in two. In group B, mild pruritus and sedation were observed in four patients, while nausea and vomiting occurred in two. No significant differences in minute ventilation, respiratory drive and respiratory timing were observed between the groups. Patients receiving fentanyl 50 micrograms showed a percentual change from baseline values as function of time (slope VE/PE'CO2) significantly below baseline at 90 and 150 min (p less than 0.05). However, the baseline values in this group reverted after 480 min. No side effects were observed in groups C or D. It is concluded that subarachnoid fentanyl 50 micrograms can cause an early respiratory depression and its use as a postoperative analgesic should be avoided in the elderly.

Aged↗

[Post-operative analgesia with sub-arachnoid fentanyl: ventilatory effects in elderly patients].

Twenty eight elderly patients scheduled for urologic surgery were randomly assigned to receive in a double blind fashion subarachnoid hyperbaric bupivacaine 15 mg with the addition of 50 micrograms (group A, n = 7), 25 micrograms (group B, n = 7), 12.5 micrograms (group C, n = 7), of fentanyl or 1 ml of saline (group D, n = 7) for a total volume of 4 ml. The pattern of breathing and the ventilatory response to CO2 were studied before 90, 150, 480 minutes after the subarachnoid injection. In group A mild pruritus and sedation occurred in 5 patients, nausea, vomiting and periodic breathing occurred in 2 patients. In group B mild pruritus and sedation were observed in 4 patients, nausea, vomiting in 2 patients. No significant changes in VE, Vt/Ti and Ti/Ttot were observed between the groups. Patients receiving 50 micrograms of fentanyl showed a slope VE/PET CO2 significantly below baseline values at 90 and 150 minutes (p less than 0.05). In this group the baseline values were restored after 480 minutes. No side effects were observed in group C and D. 25 micrograms fo fentanyl is the only dose with a significant analgesic effect without any respiratory depression.

Aged↗

Neurobehavioural effects of propofol on the neonate following elective caesarean section.

Forty mothers undergoing elective Caesarean section under general anaesthesia were allocated randomly to receive either propofol 2.8 mg kg-1 (n = 20) or thiopentone 5 mg kg-1 (n = 20) for induction of anaesthesia. Twenty neonates delivered by uncomplicated vaginal delivery were evaluated also as unmedicated controls. Neurobehavioural examinations were carried out at 1, 4 and 24 h after delivery. Infants in the propofol group had lower Apgar scores at 1 and 5 min; 25% of them had muscular hypotonus at 5 min. This hypotonus was not noted during the Early Neonatal Neurobehavioural Scale (ENNS) examination. Newborn children examined 1 h after birth, after maternal anaesthesia with propofol, showed a depression in alert state, pinprick and placing reflexes, and mean decremental count in Moro and light. There was a generalized irritability in 25% of them. This depression was not observed at 4 h.

Anesthesia, General↗