Porous silicon as a stationary phase for shear-driven chromatography.

We report on the possibility to strongly increase the mass loadability and retention capacity of shear-driven chromatography (SDC) channels by growing a thin porous silicon layer on the stationary wall part. The thickness of the produced porous silicon layers was found to increase linearly with the anodisation time, and could easily be varied between 50 and 300 nm. Combining these layers with sub-microm thin flow-through channels, we believe it is the first time a sub-microm on-chip LC system with a phase ratio similar to that in packed column HPLC (i.e., Vs/Vm approximately equal to 1.5) is obtained. The chromatographic performance of the produced channels has been tested by separating binary mixtures of coumarin dyes under RP-LC conditions. The plate height measurements, yielding Hmin, approximately equal to 0.5 microm (corresponding to more than 2 x 10(6) plates/m) for a retained component with k" = 3, showed good agreement with the theoretical expectations. Due to the presence of some macroscopic defects in the prepared layers, the quality of the separations could however only be maintained over a few millimeters of the channel length. This length was however more than sufficient to separate the coumarin mixture, given the extremely small plate heights of the system.

Chromatography, High Pressure Liquid↗

Enhancement of DNA micro-array analysis using a shear-driven micro-channel flow system.

A very simple micro-channel flow system is used to investigate the potential gain in hybridization rate stemming from the induction of a convective flow past the surface of a DNA micro-array. Reporting on a series of preliminary experiments wherein a two-dimensional convective flow is created past the surface of a conventional micro-array slide, the analysis time could be brought down from overnight waiting (16 h) to some 10 to 30 min. The experiments open the road towards the development of novel, convection-driven hybridization systems yielding shorter analysis times, and/or lower detection limits.

Oligonucleotide Array Sequence Analysis↗

Shear-flow-based chromatographic separations as an alternative to pressure-driven liquid chromatography.

It is only by developing specially designed injection and detection systems that shear-driven chromatography can become a viable alternative to HPLC. In the present paper, a dedicated zero dead-volume injection procedure is presented with which sample volumes can be injected reproducibly in the required picoliter range. In addition, a transversal detection groove system is designed which should allow to perform on-line UV-VIS absorption measurements with path lengths in the millimeter range, with an acceptable theoretical plate loss (only 20% in a 5 cm long channel) and acting as a nearly perfect wave guide.

Algorithms↗

Experimental demonstration of the possibility to perform shear-driven chromatographic separations in micro-channels.

The possibility to perform shear-driven chromatographic separations in micro-channels is demonstrated, using a novel laser-jet printed microfluidic channel system. The obtained theoretical plate numbers are in fair agreement with the theoretical calculations. Theoretical extrapolations of the separation speeds and detection limits which can be achieved when further miniaturizing the current system are presented as well.

Chromatography↗