PubMed Health⌕ Search

Biomedical subjects

D Combe

Publications and source records attributed to D Combe.

4 recordsLinked to original sources

Measuring changes in logarithmic data, with special reference to bronchial responsiveness.

Bronchial provocation tests with agents such as histamine and methacholine are commonly used in clinical and epidemiological studies of respiratory illness because bronchial hyperresponsiveness is a non-specific abnormality of the airways which is characteristic of asthma. However, measurements of bronchial responsiveness are log-normally distributed. As a result, special considerations need to be given to reporting within-subject changes in these measurements in longitudinal studies as, for example, in clinical trials or in any study in which a before-and-after experimental design is used. In these types of experiments, changes in bronchial responsiveness should not be simply expressed in the units of the measurement, such as dose of provoking agent, but must be expressed in units based on a logarithmic scale. The appropriate log-based units for measuring within-subject changes are doubling dose, fold difference or percent change. This paper explains the methods for calculating changes in these units in a statistically correct manner. All three units represent different ways of expressing the same change on a logarithmic scale. However, 'doubling dose' is only appropriate when it relates directly to the method of administering the provoking agent in doubling concentrations and 'fold difference' or 'percent change' are both appropriate for expressing any log-based changes. The methods for calculating changes in these units also apply to calculations of repeatability within test methods and to calculations of comparability and agreement between test methods. The methods are described solely for reporting changes in units of bronchial responsiveness but are applicable to other log-normally distributed measurements.

Adult↗

Selection of an obstetric data base for a microcomputer and its use for on-line production of birth notification forms, discharge summaries and perinatal audit.

A microcomputer system is described which stores data for perinatal audit and produces 'on-line' the statutory birth notification form and mother and baby discharge summary. The derivation of a minimum data-base and the methods used to obtain reliable data are outlined. The results of a trial of the production of the birth notification form for 195 deliveries are reported together with those of a further trial of 86 deliveries in which the system was used to produce both the notification form and the discharge summary. A study of the accuracy of the handwritten birth notification forms revealed a high error rate which was markedly reduced by the use of the microcomputer system. The system is now in routine use and further developments are outlined.

Computers↗

The prevalence of diabetes mellitus in a traditional-living Polynesian population: the Wallis Island survey.

The prevalence of diabetes mellitus in the traditional-living population of Wallis Island was low and comparable with that found in other rural Polynesian societies. The diabetes prevalence was 1.9% in men and 3.5% in women; impaired glucose tolerance occurred in 5.0% of men and 8.4% of women. The prevalence of obesity was significantly greater in women than in men (37.4% versus 12%, respectively, were equal to or greater than 140% ideal weight). Subjects with diabetes tended to be more obese and less active than normal subjects, but these differences, although appreciable, were not usually statistically significant. The population engages in considerable physical activity, and this, along with the traditional diet, may be responsible for the relatively low diabetes prevalence.

Adult↗