Evaluation of a new method to create a standardized muscle stretch injury.

Herein we describe a new test system to produce a standardized partial muscle-tendon junction (MTJ) stretch injury. In anesthetized rabbits the tibialis anterior (TA) muscle-tendon unit is unilaterally shortened using a custom designed clamp roller system. An angular displacement (average velocity of 450 degrees x s[-1]) is applied about the foot to plantarflex the ankle 90 degrees while the lower extremity is fixed. During ankle rotation the TA muscle is tetanically stimulated to generate an eccentric stretch injury at the MTJ. Forty-eight hours after injury, isometric torque deficit (injured/sham) was measured. Two groups of animals (N = 6 in each group) were tested with the only difference between the two groups being the initial tendon shortening. In Group 1 (tendon shortening = 1.2 cm. N = 6) the torque deficit was 36.7+/-5.9% (mean+/-SD). In Group 2 (tendon shortening = 1.5 cm. N = 6) the torque deficit was 58.7+/-7.4% (mean+/-SD). No order effect was suggested by the data (P = 0.6062), but the difference in torque deficit between the two groups was highly significant (P = 0.0001). For all tests in which the tendon was temporarily shortened before muscle stimulation and stretch (N = 12) there was a visible hematoma at the MTJ similar to the injury that is common in athletic injuries. Histological evaluation 48 h after injury revealed both fiber tearing and inflammation at the MTJ. In addition, there was focal fiber damage in the muscle belly for both groups. The damage and inflammatory process, however, were more severe in the group with greater initial tendon shortening.

Analysis of Variance↗

Clinical evaluation of a simple demand inhalation MDI aerosol delivery device.

Inhalation of medication is the preferred method for treating reversible airway obstruction; however, difficulties in the use of pressurized canisters frequently lead to suboptimal results. The Aerochamber (Monoghan Medical Corp) is a portable breath-actuated device that attaches to a metered-dose inhaler (MDI) and is designed to overcome many of the problems of aerosol delivery encountered by some patients. The attachment of this breath-actuated device to an MDI reduced pharyngeal deposition of aerosol 14-fold, but delivery of aerosol to intrapulmonary airways in normal subjects and patients with bronchitis remained unchanged. In a group of nine patients with stable asthma, inhalation of a bronchodilator aerosol using the breath-actuated device (Aerochamber) achieved effective bronchodilation similar to an optimally administered MDI. Advantages of the breath-actuated device (Aerochamber) include (1) aerosol delivery of medication whether or not the discharge of aerosol is synchronized with inhalation, (2) effective therapeutic response compared with optimally administered MDI; (3) greatly reduced deposition of aerosol in the upper airways, which might be expected to reduce adverse effects of steroids; and (4) universal application to all bronchodilator and steroid MDIs.

Adult↗