Reprogramming pacemakers enhances longevity and is cost-effective.

BACKGROUND: Historically, the majority of pulse generators implanted in the United States remain at the nominal programmed settings from the time of implant. While these nominal settings typically allow a sufficient safety margin to prevent later loss of capture with potential chronic threshold rise, the pulse generator with significant use would not be expected to last longer than that predicted by the manufacturer. However, improvements in lead technology have resulted in significantly lower chronic capture thresholds, which would permit lower programmable output settings while still allowing acceptable safety margins. Such changes could result in a significant reduction in long-term battery drain and translate into longer generator life. METHODS AND RESULTS: One hundred eighty consecutive patients undergoing implantation of permanent pacemakers at our institution were studied to determine the impact of reprogramming on pulse generator longevity and cost. Of these patients, 122 completed 6 months of follow-up at our institution and had pulse generators implanted that were capable of measuring battery current. We compared the estimated longevity based on battery current at nominal settings with that based on settings achieved in follow-up. The final settings were determined by the patient's physician using standard safety margins. The predicted longevity was 6.95 +/- 1.59 years at nominal implant settings and 11.16 +/- 2.71 years at final programmed settings (P < .001). Therefore, reprogramming extends the estimated pulse generator longevity by 4.25 +/- 2.14 years (64%) at a mean cost of $110 per patient (+37 per year extended). CONCLUSIONS: Reprogramming of permanent pacemakers is efficacious and cost-effective.

Cost-Benefit Analysis↗

Defibrillator twiddler's syndrome causing device failure in a subpectoral transvenous system.

Twiddler's syndrome is well described as a complication of cardiac pacing. Defibrillator twiddler's syndrome has been recently reported with abdominal implantations of epicardial and transvenous defibrillator systems. We report a case of a patient with a transvenous defibrillator system implanted with the pulse generator placed in the subpectoral plane. The patient developed twiddler's syndrome, which resulted in retraction of both leads. This caused inappropriate shocks due to sensing both the atrial and ventricular electrograms. While the subpectoral position leaves the generator deeper and more difficult for the patient to access, it may not lessen the chance of twiddler's syndrome. It is possible that the subpectoral position may actually predispose the patient to this malady.

Aged↗