PubMed HealthSearch

Biomedical subjects

D D Joel

Publications and source records attributed to D D Joel.

At least 19 recordsLinked to original sources

Boron neutron capture therapy of brain tumors: enhanced survival following intracarotid injection of either sodium borocaptate or boronophenylalanine with or without blood-brain barrier disruption.

The purpose of the present study was to determine whether the efficacy of boron neutron capture therapy could be enhanced by means of intracarotid (i.c.) injection of sodium borocaptate (BSH) or boronophenylalanine (BPA) with or without blood-brain barrier disruption (BBB-D). For biodistribution studies, F98 glioma-bearing rats were injected i.v. or i.c. with either BSH (30 mg of boron/kg of body weight) or BPA (24 mg of boron/kg of body weight) with or without mannitol-induced, hyperosmotic BBB-D and killed 2.5 h later. The highest tumor boron concentrations for BSH and BPA were attained following i.c. injection with BBB-D (48.6 and 94.0 microg/g, respectively) compared to i.c. (30.8 and 42.7 microg/g) and i.v. injection (12.9 and 20.8 microg). Using the same doses of BSH and BPA, therapy experiments were initiated 14 days after intracerebral implantation of F98 glioma cells. Animals were irradiated 2.5 h after i.v. or i.c. administration of the capture agent with or without BBB-D using a collimated beam of thermal neutrons at the Brookhaven Medical Research Reactor. The median survival times of rats given BSH or BPA i.c. were 52 and 69 days, respectively, for rats with BBB-D; 39 and 48 days for rats without BBB-D; 33 and 37 days for i.v. injected rats; 29 days for irradiated controls; and 24 days for untreated controls. i.c. injection of either BSH or BPA resulted in highly significant enhancement (P = 0.01 and P = 0.0002, respectively) of survival times compared to i.v. injection, and this was further augmented by BBB-D (P = 0.02 and P = 0.04, respectively) compared to i.c. injection. Normal brain tissue tolerance studies were carried out with non-tumor-bearing rats, which were treated in the same way as tumor-bearing animals. One year after irradiation, the brains of these animals showed only minimal radiation-induced changes in the choroid plexus, but no differences were discernible between irradiated controls and those that had BBB-D followed by i.c. injection of either BSH or BPA. Our data clearly show that the route of administration, as well as BBB-D, can enhance the uptake of BSH and BPA, and, subsequently, the efficacy of boron neutron capture therapy.

Alpha Particles

Boron neutron capture therapy of brain tumors: enhanced survival following intracarotid injection of sodium borocaptate with or without blood-brain barrier disruption.

PURPOSE: Sodium borocaptate (Na2B12H11SH or BSH) has been used clinically for boron neutron capture therapy (BNCT) of patients with primary brain tumors. The purpose of the present study was to determine if tumor uptake of BSH and efficacy of BNCT could be enhanced in F98 glioma-bearing rats by intracarotid (i.c.) injection of the compound with or without blood-brain barrier disruption (BBB-D). METHODS AND MATERIALS: For biodistribution studies 100,000 F98 glioma cells were implanted stereotactically into the brains of Fischer rats, and 12 days later BBB-D was carried out by i.c. infusion of 25% mannitol, followed immediately thereafter by i.c. injection of BSH (30 mg B/kg body weight). Animals were killed 1, 2.5, and 5 h later, and their brains were removed for boron determination. For BNCT experiments, which were initiated 14 days after intracerebral implantation of 1000 F98 cells, BSH (30 mg B/kg b.wt. was administered intravenously (i.v.) without BBB-D, or i.c. with or without BBB-D. The animals were irradiated 2.5 h later with a collimated beam of thermal neutrons at the Brookhaven National Laboratory Medical Research Reactor. RESULTS: The mean tumor boron concentration after i.c. injection with BBB-D was 48.6 +/- 17.2 microg/g at 2.5 h compared with 30.8 +/- 12.2 microg/g after i.c. injection without BBB-D and 12.9 +/- 4.2 microg/g after i.v. injection. The best composite tumor to normal tissue ratios were observed at 2.5 h after BBB-D, at which time the tumor:blood (T:B1) ratio was 5.0, and the tumor: brain (T:Br) ratio was 12.3, compared to 1.1 and 4.6, respectively, in i.v. injected rats. The mean survival time for untreated control rats was 24 +/- 3 days, 29 +/- 4 days for irradiated controls, 33 +/- 6 days for those receiving i.v. injection of BSH, 40 +/- 8 days for rats receiving i.c. BSH without BBB-D, and 52 +/- 13 days for BBB-D followed by BNCT (p = 0.003 vs. i.v. injected BSH). CONCLUSIONS: Intracarotid administration of BSH with or without BBB-D significantly increased tumor uptake of BSH and enhanced survival of F98 glioma-bearing rats following BNCT. BBB-D may be a useful way to enhance the delivery of both low and high molecular weight boron compounds to brain tumors. Further studies are in progress to assess this approach with other boron delivery agents.

Animals

Boron neutron capture therapy for glioblastoma multiforme using p-boronophenylalanine and epithermal neutrons: trial design and early clinical results.

A Phase I/II clinical trial of boron neutron capture therapy (BNCT) for glioblastoma multiforme is underway using the amino acid analog p-boronophenylalanine (BPA) and the epithermal neutron beam at the Brook-haven Medical Research Reactor. Biodistribution studies were carried out in 18 patients at the time of craniotomy using an i.v. infusion of BPA, solubilized as a fructose complex (BPA-F). There were no toxic effects related to the BPA-F administration at doses of 130, 170, 210, or 250 mg BPA/kg body weight. The tumor/ blood, brain/blood and scalp/blood boron concentration ratios were approximately 3.5:1, 1:1 and 1.5:1, respectively. Ten patients have received BNCT following 2-hr infusions of 250 mg BPA/kg body weight. The average boron concentration in the blood during the irradiation was 13.0 +/- 1.5 micrograms 10B/g. The prescribed maximum dose to normal brain (1 cm3 volume) was 10.5 photon-equivalent Gy (Gy-Eq). Estimated maximum and minimum doses (mean +/- sd, n = 10) to the tumor volume were 52.6 +/- 4.9 Gy-Eq (range: 64.4-47.6) and 25.2 +/- 4.2 Gy-Eq (range: 32.3-20.0), respectively). The estimated minimum dose to the target volume (tumor +2 cm margin) was 12.3 +/- 2.7 Gy-Eq (range: 16.2-7.8). There were no adverse effects on normal brain. The scalp showed mild erythema, followed by epilation in the 8 cm diameter field. Four patients developed recurrent tumor, apparently in the lower dose (deeper) regions of the target volume, at post-BNCT intervals of 7,5,3.5 and 3 months, respectively. The remaining patients have had less than 4 months of post-BNCT follow-up. BNCT, at this starting dose level, appears safe. Plans are underway to begin the dose escalation phase of this protocol.

Adult

Enhanced survival of glioma bearing rats following boron neutron capture therapy with blood-brain barrier disruption and intracarotid injection of boronophenylalanine.

Boronophenylalanine (BPA) has been used for boron neutron capture therapy (BNCT) of brain tumors in both experimental animals and humans. The purpose of the present study was to determine if the efficacy of BNCT could be enhanced by means of intracarotid (i.c.) injection of BPA with or without blood-brain barrier disruption (BBB-D) and neutron irradiation using a rat brain tumor model. For biodistribution studies, F98 glioma cells were implanted stereotactically into the brains of Fischer rats, and 12 days later BBB-D was carried out by i.c. infusion of 25% mannitol (1.373 mOsmol/ml), followed immediately by i.c. administration of 300, 500 or 800 mg of BPA/kg body weight (b.w.). At the 500 mg dose a fourfold increase in tumor boron concentration (94.5 micrograms/g) was seen at 2.5 hours after BBB-D. compared to 20.8 micrograms/g in i.v. injected animals. The best composite tumor to normal tissue ratios were observed at 2.5 hours after BBB-D, at which time the tumor: blood (T: Bl) ratio was 10.9, and the tumor: brain (T:Br) ratio was 7.5, compared to 3.2 and 5.0 respectively for i.v. injected rats. In contrast, animals that had received i.c. BPA without BBB-D had T : Bl and T:Br ratios of 8.5 and 5.9, respectively, and the tumor boron concentration was 42.7 micrograms/g. For therapy experiments, initiated 14 days after intracerebral implantation of F98 glioma cells, 500 mg/kg b.w. of BPA were administered i.v. or i.c. with or without BBB-D, and the animals were irradiated 2.5 hours later at the Brook-haven Medical Research Reactor with a collimated beam of thermal neutrons delivered to the head. The mean survival time for untreated control rats was 24 +/- 3 days, 30 +/- 2 days for irradiate controls, 37 +/- 3 days for those receiving i.v. BPA, 52 +/- 15 days for rats receiving i.c. BPA without BBB-D, and 95 +/- 95 days for BBB-D followed by i.c. BPA and BNCT. The latter group had a 246% increase in life span (ILS) compared to untreated controls and a 124% ILS compared to that of i.v. injected animals. These survival data are the best ever obtained with the F98 glioma model and suggest that i.c. administration of BPA with or without BBB-D may be useful as a means to increase the efficacy of BNCT.

Animals

Calibration of the delayed-gamma neutron activation facility.

The delayed-gamma neutron activation facility at Brookhaven National Laboratory was originally calibrated using an anthropomorphic hollow phantom filled with solutions containing predetermined amounts of Ca. However, 99% of the total Ca in the human body is not homogeneously distributed but contained within the skeleton. Recently, an artificial skeleton was designed, constructed, and placed in a bottle phantom to better represent the Ca distribution in the human body. Neutron activation measurements of an anthropomorphic and a bottle (with no skeleton) phantom demonstrate that the difference in size and shape between the two phantoms changes the total body calcium results by less than 1%. To test the artificial skeleton, two small polyethylene jerry-can phantoms were made, one with a femur from a cadaver and one with an artificial bone in exactly the same geometry. The femur was ashed following the neutron activation measurements for chemical analysis of Ca. Results indicate that the artificial bone closely simulates the real bone in neutron activation analysis and provides accurate calibration for Ca measurements. Therefore, the calibration of the delayed-gamma neutron activation system is now based on the new bottle phantom containing an artificial skeleton. This change has improved the accuracy of measurement for total body calcium. Also, the simple geometry of this phantom and the artificial skeleton allows us to simulate the neutron activation process using a Monte Carlo code, which enables us to calibrate the system for human subjects larger and smaller than the phantoms used as standards.

Body Composition

Improved apparatus for neutron capture therapy of rat brain tumors.

PURPOSE: The assembly for irradiating tumors in the rat brain at the thermal neutron beam port of the Brookhaven Medical Research Reactor was redesigned to lower the average whole-body dose from different components of concomitant radiation without changing the thermal neutron fluence at the brain tumor. METHODS AND MATERIALS: At present, the tumor-bearing rat is positioned in a rat holder that functions as a whole-body radiation shield. A 2.54 cm-thick collimator with a centered conical aperture, 6 cm diameter tapering to 2 cm diameter, is used to restrict the size of the thermal neutron field. Using the present holder and collimator as a baseline design, Monte Carlo calculations and mixed-field dosimetry were used to assess new designs. RESULTS: The computations indicate that a 0.5 cm-thick plate, made of 6Li2CO3 dispersed in polyethylene (Li-poly), instead of the existing rat holder, will reduce the whole-body radiation dose. Other computations show that a 10.16 cm-thick (4 inches) Li-poly collimator, having a centered conical aperture of 12 cm diameter tapering to 2 cm diameter, would further reduce the whole-body dose. CONCLUSION: The proposed irradiation apparatus of tumors in the rat brain, although requiring a 2.3-fold longer irradiation time, would reduce the average whole-body dose to less than half of that from the existing irradiation assembly.

Animals

Derivations of relative biological effectiveness for the high-let radiations produced during boron neutron capture irradiations of the 9L rat gliosarcoma in vitro and in vivo.

PURPOSE: Relative biological effectiveness (RBE) values for the high linear-energy-transfer particles produced during boron neutron capture therapy have generally been based on theoretical considerations or in vitro experiments. The purpose of this study was to independently determine RBE values for all of the boron neutron capture therapy dose components. METHODS AND MATERIALS: Clonogenic cell survival data were obtained for 9L rat gliosarcoma cells irradiated in the Brookhaven Medical Research Reactor thermal neutron beam both in vitro and as an intracerebral tumor. These data were analyzed using the linear quadratic model for cell survival to derive measured RBE values for all beam components and for a number of different boron compounds. RESULTS: In the absence of boron, the combined effects of the protons from the nitrogen capture, 14N(n,p)14C, and the fast neutron scatter, 1H(n,n')p, reactions generated RBEs of 3.7 in vitro and 3.2 in an in vivo/in vitro excision assay, compared to 250 kVp X rays using an end point of 1% cell survival. Apparent RBEs for the 10B(n,alpha)7Li reaction products were calculated from cell survival data following reactor irradiations in the presence of the amino acid p-boronophenylalanine, the sulfhydryl dodecaborate monomer or dimer, or boric acid. Apparent RBEs for the 10B(n,alpha)7Li reaction ranged from 1.2 to 9.8 depending on which boron compound was used. RBEs from the in vitro studies were consistently higher than from the in vivo/in vitro studies. Under any conditions, the apparent RBE for the 10B(n,alpha)7Li reaction with p-boronophenylalanine was higher than that with any other boron compound tested. CONCLUSIONS: Generally accepted RBE values for the fast neutron and 14N(n,p)14C reaction components of the total dose are too low. The apparent RBEs calculated for the 10B(n,alpha)7Li reaction were compound-dependent and consistent with differences in the distribution of 10B relative to glioma cell nuclei.

Animals

Control of intracerebral gliosarcomas in rats by boron neutron capture therapy with p-boronophenylalanine.

Boron neutron capture therapy (BNCT) of transplanted intracerebral GS-9L rat gliosarcomas was effected by irradiation at a nuclear reactor, primarily with thermal neutrons, after two intragastric doses of p-boronophenylalanine (BPA). At the time of BNCT, tumor 10B levels were approximately 40 micrograms 10B/g with tumor:blood and tumor:brain 10B concentration ratios of about 3.3:1 and 3.9:1, respectively. This resulted in calculated doses to tumor that were approximately 2.3-fold greater than those to normal brain parenchyma and brain vascular endothelium within the treatment volume. Approximately 75% of the tumor dose resulted from the 10B(n,alpha)7Li nuclear reaction. The median survival of untreated rats (n = 20) was 20 days after initiation of tumors. Reactor irradiation only (no BPA) increased the median survival to 25 days (n = 25). None of the rats in the untreated or irradiation-only groups survived longer than 34 days after initiation of tumors. Two BNCT dose levels were used: 8.9 Gy (19.3 Gy x relative biological effectiveness, or Gy-eq) and 13.4 Gy (29.0 Gy-eq). The median post-BNCT survivals of BPA-treated rats in the 8.9-Gy (n = 16) and 13.4-Gy (n = 12) groups were 60 and 120 days, respectively, including seven long-term (greater than 12 months) survivors at 8.9 Gy and six long-term (greater than 5 months) survivors at 13.4 Gy. Survival times following BPA-based BNCT (either 8.9 or 13.4 Gy) were significantly longer than those following 250-kVp X-ray doses of 15 Gy (n = 24), 22.5 Gy (n = 32) or 30 Gy (n = 26).

Animals

Selective delivery of boron by the melanin precursor analogue p-boronophenylalanine to tumors other than melanoma.

The melanin precursor analogue p-boronophenylalanine (BPA) has been used to deliver 10B to melanoma tissue for boron neuron capture therapy. Uptake studies in tumor models other than melanoma now indicate that BPA is capable of delivering therapeutic amounts of boron to tumors other than melanoma. The KHJJ murine mammary tumor carried s.c. in BALB/c mice, the GS-9L rat glioma carried both s.c. and intracranially in F-344 rats, and the human U-87 MG glioma xenograft carried s.c. in nude mice have all shown significant accumulation of boron in tumor tissue following single p.o. (intragastric) doses of BPA. In this KHJJ mammary tumor, the L isomer of BPA was preferentially accumulated compared to the D isomer, indicative of a carrier-mediated transport process. Double-label, whole-body autoradiographic studies in a pigmented murine melanoma have shown that the boron distribution (from BPA) differs from the distribution of a tritiated melanin precursor (tyrosine). Boron accumulated only in the tumor; labeled tyrosine accumulated in tumor, liver, intestinal epithelium, bone-marrow, and secretory glands. Toxicity studies in mice and rabbits indicate that, even at very high doses, BPA p.o. caused no adverse effect in tissues, on blood chemistry, or on differential leukocyte counts. These data indicate that BPA may be generally useful as a boron delivery agent for boron neutron capture therapy of tumors.

Animals

Uptake of a nido-carboranylporphyrin by human glioma xenografts in athymic nude mice and by syngeneic ovarian carcinomas in immunocompetent mice.

A tetraphenylporphyrin bearing four dicarbollide ([B9C2H11]-) cages linked to the o-phenyl ring positions by anilide bonds, known as boronated tetraphenylporphyrin (BTPP), has been synthesized in excellent yield from tetra-(o-aminophenyl) porphyrin and carborane carbonyl chloride followed by base-assisted cage opening and ion exchange to give the highly water-soluble potassium salt. Preliminary studies showed that BTPP accumulates in liver and in a syngeneic ovarian carcinoma, but not in normal brain parenchyma, of mice infused with BTPP subcutaneously for 6 or 7 days via surgically implanted osmotic minipumps. In this study, the uptake of boron was measured in human gliomas xenografted subcutaneously to athymic nude mice in which BTPP was infused intraperitoneally or subcutaneously or both for 3 or 7 days by using similar minipumps. Immunocompetent mice bearing a syngeneic ovarian carcinoma were similarly infused to provide comparative data. Bulk concentrations of boron up to 18 micrograms/g of glioma and up to 45 micrograms/g of carcinoma were observed when up to 102 micrograms/g of tissue was present in the liver after 7 days of BTPP infusion. Glioma boron concentrations were increased by approximately 80% on the average (up to 33 micrograms/g) when correspondingly greater amounts of BTPP were infused in only 3 days. Cell counts and chemical tests on blood samples from individual mice indicate that BTPP causes moderate hepatotoxicity and thrombocytopenia. This hepatohematic toxicity syndrome should be taken into account if BTPP or a similar agent is used for boron neutron-capture therapy (BNCT) of human malignancies.

Animals

Boron neutron capture therapy of intracerebral rat gliosarcomas.

The efficacy of boron neutron capture therapy (BNCT) for the treatment of intracerebrally implanted rat gliosarcomas was tested. Preferential accumulation of 10B in tumors was achieved by continuous infusion of the sulfhydryl borane dimer, Na4(10)B24H22S2, at a rate of 45-50 micrograms of 10B per g of body weight per day from day 11 to day 14 after tumor initiation (day 0). This infusion schedule resulted in average blood 10B concentrations of 35 micrograms/ml in a group of 12 gliosarcoma-bearing rats and 45 micrograms/ml in a group of 10 similar gliosarcoma-bearing rats treated by BNCT. Estimated tumor 10B levels in these two groups were 26 and 34 micrograms/g, respectively. On day 14, boron-treated and non-boron-treated rats were exposed to 5.0 or 7.5 MW.min of radiation from the Brookhaven Medical Research Reactor that yielded thermal neutron fluences of approximately 2.0 x 10(12) or approximately 3.0 x 10(12) n/cm2, respectively, in the tumors. Untreated rats had a median postinitiation survival time of 21 days. Reactor radiation alone increased median postinitiation survival time to 26 (5.0 MW.min) or 28 (7.5 MW.min) days. The 12 rats that received 5 MW.min of BNCT had a median postinitiation survival time of 60 days. Two of these animals survived greater than 15 months. In the 7.5 MW.min group, the median survival time is not calculable since 6 of the 10 animals remain alive greater than 10 months after BNCT. The estimated radiation doses to tumors in the two BNCT groups were 14.2 and 25.6 Gy equivalents, respectively. Similar gliosarcoma-bearing rats treated with 15.0 or 22.5 Gy of 250-kilovolt peak x-rays had median survival times of only 26 or 31 days, respectively, after tumor initiation.

Animals

Intestinal uptake of fluorescent microspheres in young and aged mice.

Rhodamine B-labeled synthetic latex particles (microspheres), 1.8 micron in diameter, were administered by gavage 5 days per week to young (24 days) and aged (18 months) mice. After 25 days (19 gavages), the particles were assayed in solubilized tissues by depositing them on filters and counting under fluorescence microscopy. Aged mice exhibited significantly more fluorescent particle accumulation in Peyer's patches but significantly less in lungs than young mice. Mesenteric lymph nodes and Peyer's patch-free intestinal segments contained measurable latex, but differences between young and aged animals were not significant. Liver contained only trace amounts of latex, and spleen and kidney were latex free in both young and aged animals. Nonquantitative observations on KOH-glycerol-cleared whole Peyer's patches and slices of liver, lung, and mesenteric lymph node were similar.

Aging

Effect of PEEP on regional ventilation and perfusion in the mechanically ventilated preterm lamb.

Improvement of gas exchange through closer matching of regional ventilation (V) and lung perfusion (Q) with the application of positive end-expiratory pressure (PEEP) was evaluated in vivo in six mechanically ventilated preterm lambs (107-126 days/145 days gestation). Changes in V and Q were determined from in vivo scintigraphic measurements in four lung regions with inhaled radioactive 81mKr, and infused 81mKr/dextrose and/or [99mTc]MAA as PEEP was applied at 2, 4, and 6 cm H2O in each animal. Dynamic compliance varied between 0.02 and 0.40 ml/cm H2O, which was consistent with surfactant deficiency. As PEEP was increased, the regional distribution of Q shifted from the rostral to the caudal lung regions (p less than 0.02 to less than 0.05), while that of V remained unchanged. Regional V/Q matching improved together with a trend towards improvement of arterial blood gases as PEEP was increased from 2 to 4 cm H2O. Pulmonary scintigraphy offers a noninvasive methodology for the quantitative assessment of regional V and Q matching in preterm lambs and may be clinically applicable to ventilated neonates.

Animals

Distribution of lung-associated lymphocytes from the caudal mediastinal lymph node: effect of antigen.

Lymphocytes from the efferent lymph of the caudal mediastinal lymph node (CMLN) were labelled in vitro with 125I-iododeoxyuridine [125I]UdR and Na2(51)CrO4. The labelled cells were re-infused i.v. and their distribution in organs/tissues was determined 20-24 hr later. As indicated by tissue 125I-activity, pulmonary lymphoblasts had a marked tendency to relocate in the lung, regional pulmonary lymph nodes and spleen. Localization of efferent CMLN lymphoblasts was greater in antigenically stimulated segments compared to unstimulated segments of the lung. Dual antigen experiments indicated that the increased localization was not specific for the antigen which stimulated production of lymphoblasts used for in vitro labelling and reinfusion. Intranodal labelling of blasts by the direct injection of [125I]UdR supported the results obtained from in vitro labelling. In these studies, comparisons were made with the localization of lymphocytes obtained from thoracic duct lymph.

Animals