PubMed Health⌕ Search

Biomedical subjects

D D McPherson

Publications and source records attributed to D D McPherson.

At least 37 records · Page 2Linked to original sources

Computation of vascular flow dynamics from intravascular ultrasound images.

Analysis of three-dimensional velocity profiles and wall shear stress distribution in a segment of an artery reconstructed from in vivo imaging data are presented in this study. Cross-sectional images of a segment of the abdominal aorta in dogs were obtained using intravascular ultrasound (IVUS) imaging employing a constant pull back technique. Simultaneous measurement of pressures distal and proximal to the vessel segment along with gated pulsed Doppler velocity measurements were also obtained. The three-dimensional geometry of the vascular segment was reconstructed from the IVUS images during peak forward flow phase, and a computational mesh was constructed from the data. A quasi-steady analysis of incompressible Newtonian fluid was performed with a finite difference general purpose computational analysis program FLOW3D. The velocity at the inlet and pressure at the outlet measured at the corresponding time (time referenced to ECG) were used to specify the boundary conditions for the computational flow model. The computed results compared favorably with previously reported results. The purpose of the present study was to analyze the hemodynamics in vascular segments from morphologically realistic three-dimensional reconstructions. The method can be potentially employed in analyzing the hemodynamics in the region of atherosclerotic plaques at various stages of development and the reactivity of the vessel in response to pharmacological and mechanical interventions.

Animals↗

Development of inherently echogenic liposomes as an ultrasonic contrast agent.

Ultrasonic contrast agents have been developed for improved assessment of blood flow and tissue perfusion. Many of these agents are not inherently acoustically reflective (echogenic), and nearly all are not suitable for tissue specific targeting. The purpose of this study was to develop acoustically reflective liposomes, which are suitable for antibody conjugation, without using gas or any other agent entrapment. Echogenic liposomes were prepared from phosphatidylcholine (PC), phophatidylethanolamine (PE), phosphatidylglycerol (PG), and cholesterol (CH), using a dehydration/rehydration method. The formulation was optimized for higher acoustic reflectivity by varying the lipid composition. Liposomes were imaged with a 20 MHz intravascular ultrasonic imaging catheter. Echogenicity levels were expressed using pixel gray scale. The presence of PE and PG at specific concentrations improved echogenicity due to their effects on liposomal morphology as confirmed by freeze-etch electron microscopy. The acoustic reflectivity of liposomes was retained when liposomes were treated with blood at room temperature and 37 degrees C under in vitro conditions. It was demonstrated that the liposomes were also acoustically reflective in vivo after they were injected into a miniswine model. We have developed echogenic liposomes that are stable and suitable for tissue specific targeting as a novel contrast agent. This new contrast agent can be used for ultrasonic image enhancement and/or treatment of targeted pathologic sites.

Cholesterol↗

Myocardial acoustics in pediatric allograft rejection.

BACKGROUND: Ultrasonographic tissue characterization is the assessment of physical properties of biologic tissue on the basis of quantitative analysis of its acoustic characteristics. Abnormalities in microscopic structure that occur with cardiac allograft rejection may result in characteristic alterations in myocardial acoustics. Ultrasonographic tissue characterization may allow noninvasive detection of rejection. METHODS: Findings in 22 pediatric heart transplant patients undergoing routine surveillance for rejection by endomyocardial biopsy were prospectively evaluated. Off-line ultrasonographic tissue characterization analysis was done on transthoracic echocardiograms obtained at each biopsy. Within patients, tissue characterization texture measures derived from the ultrasonographic image data were compared with histologic findings. Univariate multiple regression analysis was used to identify texture measures associated with acute allograft rejection in a subgroup (n = 8) with at least one biopsy-proven episode of moderate rejection. RESULTS: Measures of homogeneity (co-occurrence matrix correlation and heterogeneity (run-length nonuniformity) decreased with moderate rejection (p < 0.03). Homogeneity measures decreased if the patient had a previous episode of rejection. Several measures of heterogeneity (gray level difference and run-length statistics) were affected by the presence of edema. Run-length nonuniformity was the only measure that differentiated moderate rejection from edema. Discriminant analysis on all 22 patients correctly identified 96% of first rejection episodes (sensitivity 80%, specificity 64%), 93% of moderate and severe rejection episodes (sensitivity 71%; specificity 62%), and 69% of all rejection episodes (sensitivity 51%, specificity 91%). CONCLUSIONS: Histologic changes associated with moderate and severe pediatric allograft rejection as reflected by characteristic alterations in myocardial acoustics can be assessed with ultrasonographic tissue characterization. Histologic changes associated with transplantation itself (resolution of rejection and edema) also affect myocardial acoustics and must be taken into account in rejection surveillance.

Acute Disease↗

Can atherosclerotic coronary arteries vasodilate? An intraoperative high-frequency epicardial echocardiographic study.

Our purpose was to evaluate the vasodilating responses of atherosclerotic coronary arteries using intraoperative high-frequency (12 MHz) epicardial echocardiography. We obtained continuous high-frequency epicardial echocardiographic recordings during surgery, and determined cross-sectional lumen area from 17 coronary arterial segments (12 patients). Nitroglycerin (100 to 400 micrograms/min) was administered intravenously to reduce mean (+/- SEM) arterial pressure 14 +/- 1.8 mm Hg. The cross-sectional arterial images were classified using 3 different parameters: arterial lumen area, percentage of the arterial wall circumference that was atherosclerotic (wall thickness > 0.7 mm), and presence of an eccentrically shaped arterial lumen (maximal/minimal luminal diameter > 1.5). Nine arterial segments had small (< 5.0 mm2) arterial lumens (1.7 +/- 0.40 mm2 [+/- SEM; range 0.6 to 3.9]). With nitroglycerin, the luminal area increased 0.8 +/- 0.28 mm2 (range 0 to 2.5), and 39 +/- 12.1% (range 0 to 117). The remaining 8 segments had larger (> 5.0 mm2) lumens (8.7 +/- 0.91 mm2 [range 5.0 to 11.9]). With nitroglycerin the luminal area increased 4.3 +/- 1.11 mm2 (range 1.4 to 11.4), and 51 +/- 10.2% (range 16 to 96). Seven arterial segments had eccentric lumens; mean maximal/minimal ratio was 1.8 +/- 0.08 (range 1.6 to 2.0). The area increased 39 +/- 7.3% (range 16 to 71) with nitroglycerin. In the 10 concentrically shaped lumens (maximal/minimal lumen diameters 1.3 +/- 0.04 [range 1.1 to 1.5]), nitroglycerin increased luminal area by 48 +/- 12.6% (range 0 to 117) (p = NS).(ABSTRACT TRUNCATED AT 250 WORDS)

Coronary Artery Disease↗

In vivo assessment of nonlinear myocardial deformation using finite element analysis and three-dimensional echocardiographic reconstruction.

In vitro data have shown that the myocardium exhibits nonlinear passive stress-strain relationship and a non-linear pressure-volume relationship. A finite element (FE) analysis and optimization algorithm was used on three-dimensional reconstructed left ventricular (LV) geometry using echocardiographic images, along with hemodynamic measurements, in seven closed-chest dogs to show a nonlinear stress-strain relationship in vivo. Our analysis included the computation of Poisson's ratio from the measured volumetric strain of the myocardium and a simulated pericardial pressure load ("equivalent pericardial pressure") applied to the epicardial surface of the reconstructed LV. LV geometry was reconstructed in three or four incremental time steps in diastasis and the myocardium was assumed to be homogeneous, isotropic, and linearly elastic during these short intervals in this initial study. Simultaneous LV chamber pressure and equivalent pericardial pressure were incorporated into the algorithm to predict actual LV expansion. Computations were performed iteratively at each interval to compute the optimized elastic modulus. By performing the FE analysis and optimization at each interval (a step-wise linear analysis approach), a linear relationship between the myocardial elastic modulus and LV chamber pressure was derived (r = .87 to .98). Such a linear relationship is equivalent to an exponential myocardial stress-strain relationship in vivo. Detailed measurement of nonhomogeneous regional deformation are becoming possible with the advent of sophisticated imaging techniques. The methodology described in this study, with appropriate modifications in the FE analysis and optimization algorithms, can be applied to assess the complex three-dimensional pressure-deformation characteristics in vivo.

Algorithms↗

Doppler catheter tip localization using color enhancement.

The objective of this research was to determine if the ultrasound emissions of the Doppler catheter can be used to locate its position in 3 dimensions by conventional echocardiography. A Doppler catheter has previously been shown to permit nonfluoroscopic retrograde catheterization of the aortic root and left ventricular chamber by using velocity waveform polarity for directional guidance. A significant difficulty in providing ultrasound catheter guidance, however, has been the inability to recognize the Doppler catheter tip, because each point at which a flexible catheter crosses the image plane can be misinterpreted as the catheter tip. Initial in vitro water bath trials were performed using the Doppler catheter attached to a standard velocimeter. Using a 5 MHz imaging transducer and color Doppler methods, the presence or absence of a banded color pattern which could demarcate the Doppler catheter tip was recorded at various angles in and out of the scanning plane. Using Doppler retrograde guidance and transesophageal echocardiography, color Doppler banded patterns, which could identify the Doppler catheter tip, were investigated in the dog aorta. In order to understand the physical mechanisms involved, a series of water bath trials were then conducted using the Doppler catheter attached to a velocimeter which was synchronized to the echo machine. Initial nonsynchronized water bath trials revealed distinct banded color patterns demarcating the Doppler catheter tip when it pointed in any direction within the beam width, except for a 40 degrees blind cone directly away from the imaging transducer.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Utility of transesophageal echocardiography in the diagnosis of disease of the thoracic aorta.

PURPOSE: Transesophageal echocardiography (TEE) offers a rapid, minimally invasive method for diagnosing thoracic aortic disease. High-resolution images are possible because of the close proximity of the esophagus and vascular structures within the chest. Lung and chest wall components have little influence on the image quality and a virtually unobstructed view of the heart, thoracic aorta, and pulmonary vasculature is seen. The role of TEE in diagnosing diseases of the thoracic aorta is rapidly developing. The purpose of this study is to define the role of TEE in the diagnosis of thoracic aortic disease. METHODS: Between July 1, 1989 and December 31, 1992, 1005 TEEs were performed at our center. Of these, 199 (125 men, 74 women) were entered into our aortic disease registry. Indications for the studies included 37 referrals to rule out aortic dissection, 18 to assess aortic aneurysm, 55 to assess for an intraaortic source of embolus, 9 to rule out intraaortic thrombus, and 13 with familial hyperlipidemia being followed to mark response to low-density lipoprotein apheresis. In 67 cases, subclinical aortic plaquing was found incidentally. No complications from the TEE procedure were encountered. RESULTS: In cases of suspected aortic dissection, TEE was equal to computed tomography (CT) scanning in identifying the type (DeBakey) and extent of thoracic aortic dissection. In addition, TEE provided information regarding functional status of the aortic valve, identified interluminal communications, and assessed blood flow and thrombus burden in the false lumen. TEE correctly identified true aneurysms, intraluminal thrombus, and plaques as possible sources of emboli. One false-positive CT scan result for aortic dissection was seen and was ruled out both by TEE and angiography. CONCLUSION: Biplane TEE can be considered the method of choice in diagnosing disease of the thoracic aorta. Information from TEE can be obtained at the patient's bedside or in the operating suite, to assess surgical results before procedure termination and afterward for follow-up. Adjunctive magnetic resonance imaging, CT scanning, or aortography may be needed to assess extension of the disease process into the abdomen or pelvis or to plan surgical intervention.

Adult↗

A method for automatic edge detection and volume computation of the left ventricle from ultrafast computed tomographic images.

RATIONALE AND OBJECTIVES: Detection of endocardial and epicardial borders of the left ventricle (LV) using various imaging modalities is time-consuming and prone to interpretive error. An automatic border detection algorithm is presented that is used with ultrafast computed tomographic images of the heart to compute cavity volumes. METHODS: The basal-level slice is identified, and the algorithm automatically detects the endocardial and epicardial borders of images from the basal to the apical levels. From these, the ventricular areas and chamber volumes are computed. The algorithm uses the Fuzzy Hough Transform, region-growing schemes, and optimal border-detection techniques. The cross-sectional areas and the chamber volumes computed with this technique were compared with those from manually traced images using canine hearts in vitro (n = 8) and studies in clinical patients (n = 27). RESULTS: Though the correlation was good (r = .88), the algorithm overestimated the LV epicardial area by 4.8 +/- 6.4 cm2, though this error was not statistically different from zero (P > .05). There was no difference in endocardial areas (r = .95, P > .05). The algorithm tended to underestimate the end-diastolic volume (r = .94) and the end-systolic volume (r = .94), although these errors were not statistically different from zero (P > .05). The algorithm tended to underestimate the ejection fraction (r = .80), although this error was not statistically different from zero (P > .05). CONCLUSIONS: Automatic detection of myocardial borders provides the clinician with a useful tool for calculating chamber volumes and ejection fractions. The algorithm, with the corrections suggested, provides an accurate estimation of areas and volumes. This algorithm may be useful for contour border identification with ultrasound, positron-emission tomography, magnetic resonance imaging, and other imaging modalities in the heart, as well as other structures.

Algorithms↗

Atherosclerotic plaque evolution in the descending thoracic aorta in familial hypercholesterolemic patients. A transesophageal echo study.

We explored the concept that transesophageal echocardiography can be used as a tool to detect, characterize, and study plaque morphology in the descending thoracic aorta. The pattern of atherosclerotic plaques in the descending thoracic aorta in familial hypercholesterolemic (FH) patients was evaluated. Additionally, evolution of plaque characteristics as a result of therapy was analyzed. In a randomized prospective protocol, eight FH patients (five men and three women, aged 23 to 65 years [mean +/- SD, 42 +/- 14 years]) receiving standard therapy (n = 3; baseline low-density lipoprotein [LDL] cholesterol, 222 +/- 71 mg/dL, mean +/- SD) or LDL apheresis (n = 5; baseline LDL cholesterol, 262 +/- 51 mg/dL) were studied. Baseline and follow-up (mean, 12 months) transesophageal echocardiographic studies were performed. Measurements obtained were atherosclerotic plaque area (PA), aortic wall area (WA), total arterial area (TAA), and plaque-to-wall area ratio (PWR). LDL cholesterol decreased in both groups. The greatest severity of plaque was detected at 30 to 35 cm from the incisors (approximately 15 to 20 cm from the aortic arch). The smallest plaques were present at the arch and more distal descending aorta. In the control group, TAA, PA, and PWR did not change significantly (P = NS versus baseline). In the LDL-apheresis group, TAA increased (P < .05 versus baseline), PA decreased in three of five patients (P = NS versus baseline), and PWR fell (P < .05 versus baseline).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Feasibility of transcolonic and transgastric abdominal vascular ultrasound.

Abdominal vascular ultrasound is hampered by tissue attenuation. To improve imaging, the feasibility of real-time color Doppler transcolonic and transgastric abdominal vascular ultrasound was evaluated. A monoplane 5 MHz transesophageal probe was inserted via a proctoscope in five patients with normal colons. At 25 cm (end of proctoscope), the aortic bifurcation and iliac arteries were dynamically imaged with high resolution. In three patients undergoing abdominal surgery, the surgeon grasped the probe and advanced it further through the descending to the transverse colon to examine further vascular structures. High resolution two-dimensional imaging and color Doppler flow were obtained from the abdominal aorta, the origins and proximal portions of the superior mesenteric artery, and the renal and the inferior mesenteric arteries. Additionally, the inferior vena cava, left renal vein, and portal system were imaged. All vascular structures imaged were within 3 cm of the probe. In two additional patients undergoing abdominal surgery and transesophageal echocardiography, the surgeon grasped the probe in the stomach and placed it on various vascular structures. The results were similar and the celiac trunk was also imaged. This technique, when integrated with fiberoptics for guidance, could provide a method for abdominal vascular ultrasound with less tissue-imposed attenuation, providing high resolution imaging and allowing additional structure recognition. This has potential applications for studying patients with disease of the abdominal aorta or its branches.

Abdomen↗

Validation by high-frequency epicardial echocardiography of a new method of analyzing coronary angiography quantitatively in coronary artery disease.

In coronary atherosclerosis, the arterial lumen size and shape can be markedly irregular, eccentric and variable. Traditional angiographic interpretation, emphasizing percent diameter stenosis, has been criticized as an inadequate descriptor of such diseased arteries. Computerized quantitative angiographic technologies, yielding a true lumen area measurement, may be superior. High-frequency epicardial echocardiography (HFEE) is a technique that allows on-line evaluation of coronary arterial wall and lumen at the time of cardiac surgery. It has been extensively validated and yields accurate measurements of normal and diseased coronary lumen areas. This study compares quantitative coronary angiography (QCA) estimates of lumen area to those obtained by HFEE to determine if the computerized angiographic method more accurately predicts residual luminal area than traditional angiographic percent diameter stenosis measurements. Although actual luminal morphology was quite variable, there was a good correlation between lumen areas determined by HFEE versus QCA: r = 0.85, n = 67, HFEE = 0.8 QCA - 0.1 (HFEE 4.0 +/- 0.30 mm2, mean +/- SEM range 0.3 to 14.0; QCA 5.1 +/- 0.40 mm2, range 0.7 to 11.8). Percent diameter stenosis determined from the angiograms did not correlate well with HFEE or QCA measurements of residual luminal area. Separation of "normal" arterial segments (defined as < 25% diameter stenosis) from "abnormal" segments (> 50% diameter stenosis) by angiography did not agree with lumen areas as defined by either HFEE or QCA. Better separation occurred when QCA-determined luminal areas were used to separate normal from abnormal arterial segments.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Application of finite-element analysis with optimisation to assess the in vivo non-linear myocardial material properties using echocardiographic imaging.

An application of finite-element analysis with an optimisation technique to assess the myocardial material properties in diastasis in vivo is described. Using the data collected from an animal model, the three-dimensional geometry of the left ventricular chamber, at several times in diastole, was reconstructed. From the measurement of the ventricular chamber pressure during image acquisition, finite-element analysis was performed to predict the expansion during diastasis. Initially, by restricting the motion of the epicardial nodes and computing the reaction forces, an 'equivalent pericardial pressure' was determined and applied in subsequent analysis. The duration of diastasis was divided into three or four intervals and the analysis was performed at each interval to assess the material properties of the myocardium. Using such a step-wise linear approach, the non-linear material properties of the myocardium during passive expansion was determined. Our results demonstrated that the computed 'equivalent pericardial pressure' increased with and was smaller than the corresponding left ventricular chamber pressure. The passive myocardium exhibited a linear tangent modulus against chamber pressure relationship which is equivalent to an exponential stress/strain relationship, similar to those suggested by in vitro studies.

Animals↗

Variable morphology of coronary atherosclerosis: characterization of atherosclerotic plaque and residual arterial lumen size and shape by epicardial echocardiography.

The purpose of this study was to evaluate the in vivo characteristics of coronary atherosclerosis by using high frequency epicardial echocardiography. High frequency epicardial echocardiography was used to evaluate residual lumen and wall morphology at the sites of maximal coronary atherosclerosis in 26 patients undergoing coronary artery bypass grafting. The maximal/minimal wall thickness ratio was 3.1 +/- 0.2 (mean +/- SEM) with a large range (1.3 to 7.5). Portions of the wall were normal in 16 of 31 lesions; the percent normal circumference ranged from 9% to 85%. Maximal/minimal lumen diameter ratio was 1.5 +/- 0.1 (range 1.1 to 2.9). The shape of the residual coronary lumen was noncircular in 16 lesions: oval in 13 and complex in 3. The residual coronary lumen was eccentrically placed within six arteries. These data emphasize the variability of residual lumen and wall geometry in atherosclerosis.

Coronary Artery Bypass↗

A Doppler guided retrograde catheterization system.

A Doppler guided retrograde catheterization system was developed to accurately catheterize the aortic root and left ventricular chamber without X-ray. This system consists of a 20 MHz, 0.076 mm thick x 1.016 mm diameter pulsed Doppler crystal integrated into the tip of a 100 cm multipurpose triple lumen catheter. Two lumens (0.61 mm) are used for electrodes; a third lumen (1.245 mm) may be used for guidewire and pressure determination; and the system is attached to a flow velocimeter. In an aortic arch flow model, the principles of Doppler signal guidance were confirmed with flow toward the catheter tip demonstrating positive signals and flow away from the catheter tip demonstrating negative signals. The magnitude and polarity (direction) of the detected phasic and mean velocities were utilized to guide catheterization in six dogs. Using the reversal of Doppler signal polarity to indicate branch entry and manipulating the catheter so as to maintain maximal positive axial velocity, the Doppler catheter was successfully advanced from the femoral artery to the aortic valve. Branches detected by the Doppler system were confirmed by fluoroscopy. The aortic valve was audible when approached and the left ventricular chamber was recognized by its characteristic pressure waveform. The Doppler guided retrograde catheterization system offers new technology to perform left heart catheterization without X-ray and may prove useful in a variety of settings including the development of invasive ultrasonic diagnostic and therapeutic technology.

Animals↗

Segmentation of high-frequency ultrasound images of atherosclerotic coronary arteries.

High-frequency epicardial echocardiography (HFE) is an ultrasound imaging technique capable of visualizing coronary arteries in cross-section. Use of this imaging technique in the intra-operative setting can provide information about the structure of coronary arteries. As a result of time constraints imposed in this setting, there is a need for rapid, on-line analysis of HFE images. An algorithm for segmenting HFE images of coronary arteries into wall and luminal regions is described in this paper. The algorithm is more objective and time efficient than manual methods. A validation study with post-mortem human hearts demonstrated an excellent correlation (r = 0.99 for luminal areas, r = 0.99 for wall areas) between HFE images segmented with the algorithm and by manual methods, and a good correlation (r = 0.90 for luminal areas, r = 0.86 for wall areas) between HFE images segmented with the algorithm and manually segmented images of histological samples of the corresponding coronary arterial segments. Use of the algorithm for intra-operative HFE image segmentation may reduce the amount of time required for HFE image analysis and allow for an increased amount of data collection and analysis in the operating room.

Algorithms↗

Coronary arterial remodeling studied by high-frequency epicardial echocardiography: an early compensatory mechanism in patients with obstructive coronary atherosclerosis.

Coronary arterial remodeling is a compensatory mechanism that may limit the adverse effects of coronary obstructive lesions by expansion of the entire vascular segment. To determine if this compensatory anatomic change occurs in patients, high-frequency epicardial echocardiography using a 12 MHz transducer was performed during open heart surgery in 33 patients (10 with normal coronary arteries undergoing valvular surgery and 23 with coronary atherosclerosis). From stop-frame videotape high-frequency epicardial echocardiographic images, cross-sectional measurements of luminal area and total arterial area (lumen, intima, media and dense adventitia) were made in the patients with atherosclerosis at the site of arterial lesions and from the most proximal portion of the same artery. Remodeling was defined as enlargement of the total arterial area. In normal arteries measurements were made from proximal and midarterial locations. In the patients with normal coronary arteries, total arterial area, as determined by high-frequency echocardiography, decreased from the proximal site to the midportion of the artery (from 10.4 +/- 0.9 to 8.4 +/- 1.0 mm2, p less than 0.05); luminal area also decreased (from 6.0 +/- 0.6 to 4.5 +/- 0.7 mm2, p less than 0.05). In patients with coronary arterial lesions, luminal area also decreased from the proximal site to the arterial lesion site (from 5.3 +/- 0.6 to 2.3 +/- 0.3 mm2, p less than 0.05), but total arterial area increased (from 11.6 +/- 1.0 to 13.0 +/- 1.0 mm2, p less than 0.05). Of the 25 coronary arteries evaluated, only 4 had angiographic evidence of coronary collateral formation. These data indicate that coronary arterial remodeling is an important compensatory mechanism in obstructive coronary disease.(ABSTRACT TRUNCATED AT 250 WORDS)

Cardiac Surgical Procedures↗

Quantitative shape descriptors of left-ventricular cine-CT images.

In order to assess regional diastolic function of the left ventricle (LV), we use LV cine-CT images to build finite element models. To quantitatively evaluate the accuracy of our geometric reconstruction technique used in building these models, we introduce a new measure of shape-similarity, and compare and contrast the results obtained from the new measure to the results obtained from traditional shape-similarity measures. All of these measures are used to compare the endocardial and epicardial LV contours obtained from cine-CT images of canine hearts with those obtained from video images of the same hearts. Our results show that our imaging procedure accurately reproduces shape, and further suggest that the new descriptor has the sensitivity and resolution required to distinguish between images separated by as little as 3 mm.

Animals↗