Experience with the helix cava filter.

A new caval filter of helico-spiral geometry (Helix-Filter) was implanted in 13 patients for the prevention of pulmonary embolism (PE). The indications for implantation were: recurrent PE despite adequate anticoagulation (5 cases) or contraindication to anticoagulation (3 cases), incomplete local therapeutic fibrinolysis after severe paracentral PE (2 cases), and prophylaxis in high risk patients (3 cases). Implantation was effected by the saphenous/femoral vein approach in 12 patients, and via the right atrial appendage during open heart surgery in one instance. There were no intraoperative technical problems and in no case was the filter misplaced. During the follow-up period (mean 14.8 months, maximum 28 months) no filter-related complications were encountered. One patient with an exceptionally enlarged vena cava, due to abnormal renal vein inflow, had a fatal recurrent PE despite high dosage heparinization. One patient with an event-free follow-up died 12 months after filter placement from unrelated diseases. The remaining 11 patients are free of symptoms with no recurrent PE, no deterioration of venous circulation or presence of caval thrombosis. Emboli trapped at the filter were documented in 2 patients; spontaneous resolution occurred in one case. Experimental and early clinical results indicate that the hemodynamically optimal design of the Helix-Filter permits controlled and uniform luminal filtering with high patency. As such, it represents an alternative and highly promising solution to the problem of "mechanical" prevention of pulmonary embolism in selected patients.

Adult↗

The helix filter: a new vena caval filter for the prevention of pulmonary embolism.

The helix caval filter is a continuous band spiral composed of a highly elastic metal alloy. A vertical double-helix coil fixes the filter in the infrarenal vena cava by elastic expansion while a watch spring type horizontal coil works as the filtering element. The diameter of the filter can be reduced by torsion from 32 to 7 mm. Transvenous implantation was performed under fluoroscopy using a newly developed instrument featuring intraoperative angiographic control, high flexibility, a guidance system, and a well-controlled release mechanism. The filter and the implantation technique were tested in a circulation system and in 10 dogs and 4 calves (follow-up 3-91 days). In addition, two filters were released intentionally into the right atrium of a dog and a calf. Flow resistance of the filter is negligible up to more than 10 1/min. Thrombi larger than 3.5 mm were filtered out reliably. Lethal complications, filter migrations or perforations did not occur in animal experiments. Filter coils which are in contact with the vessel wall become firmly incorporated within 3 to 4 weeks. The patency rate of the vena cava was 80% (8/10) for dogs and 100% (4/4) for calves. Implantations in the right atrium did not cause any symptoms. The filter's design allows fixation without hooks or spikes and consequently makes transvenous extraction possible up to 7-10 days after implantation. Comparable clinical results could extend the indications for caval filter implantation, and the decision which is still difficult today could be made easier.

Animals↗