PubMed Health⌕ Search

Biomedical subjects

D E Hartley

Publications and source records attributed to D E Hartley.

17 recordsLinked to original sources

Endoluminal aortic grafting with renal and superior mesenteric artery incorporation by graft fenestration.

PURPOSE: To explore the use of juxta- and suprarenal aortic segments for endograft fixation in abdominal aortic aneurysm (AAA) patients and to develop methods of graft implantation that use endograft fenestrations to preserve renal and visceral vessel perfusion. METHODS: From August 1998 to May 2000, 13 AAA patients with unsuitable infrarenal aortic necks were treated with custom-designed endovascular grafts employing the juxta- and suprarenal aortic segments for proximal sealing. Flow to 33 renal and superior mesenteric arteries was maintained via graft fenestrations that were aligned by use of radiopaque graft markers. The fenestration-orifice interface for renal arteries was secured with modified balloon-expandable stents. RESULTS: All fenestrated grafts were deployed as planned, and all target vessels (33/33) were preserved. Two patients did not receive any stents, one being the first in the series and another who had incorporation of a renal accessory artery only. Without the use of transgraft stenting, 5 renal arteries would have been occluded by the endograft or poorly perfused. Procedural success was 100%. No conversion to open operation or graft-related complications occurred. There was no primary endoleak in any patient by angiographic criteria. Two patients required additional surgical procedures related to access vessels. Periprocedural mortality at 30 days was nil. Follow-up ranging from 3 to 24 months on all patients has not demonstrated any proximal or distal endoleaks. One stented renal vessel has occluded; all other arteries remain patent at last examination. CONCLUSIONS: This study has demonstrated the ability to successfully place a multifenestrated endoluminal graft in an aortic aneurysm using juxta- and suprarenal aortic segments to obtain a satisfactory seal. Stenting of the fenestration-renal ostium junction has helped to maintain renal patency.

Aortic Aneurysm, Abdominal↗

Fenestration in endovascular grafts for aortic aneurysm repair: new horizons for preserving blood flow in branch vessels.

PURPOSE: To describe techniques for deploying fenestrated stent-grafts that use partial graft deployment and guided tracking of the fenestration to the arterial orifice. TECHNIQUE: Fenestrations have been added to custom-made tube grafts and commercially manufactured Zenith stent-graft systems to preserve perfusion of aortic side branches. Partial device deployment, orientation markers on the endograft, and intraoperative angiography enable maneuvering of the fenestration over the orifice of the target vessel with the aid of guiding catheters. Placement of a Palmaz stent overlapping the fenestration and vessel orifice secures the junction. Two variations of fenestration have preserved blood flow in renal arteries during endovascular repair of abdominal aortic aneurysms (AAAs); similar techniques have maintained flow to the celiac axis in a thoracic aortic aneurysm. CONCLUSIONS: Accurate placement of a fenestration over the orifice of a target vessel is feasible, but long-term maintenance of position is dependent on secure graft fixation. This capability brings us a step closer to overcoming the problem of inadequate necks in infra-renal AAAs, especially when the neck is foreshortened by asymmetry of the renal origins. It may also pave the way for the eventual replacement of the entire aorta with an endoluminal graft.

Aged↗

Analytical modeling and numerical simulation of forces in an endoluminal graft.

PURPOSE: To utilize mathematical analysis and computational fluid dynamics (CFD) to investigate the forces acting within the pressurized aorta and upon a stent-graft and how these forces may affect the ongoing performance of the stent-graft. METHODS: Analytical force balance analysis and CFD simulations using the Fluent code were used to mimic blood flow through a bifurcated stent-graft in a person at rest. Steady-state blood flow was assumed in which the inlet pressure approximated the mean blood pressure (100 mm Hg) and the blood flow velocity was an approximation of the peak systolic flow rate (0.6 m/s). Two sizes of endoluminal grafts were analyzed: the larger graft had an inlet diameter of 3 cm and outlet diameters of 1 cm; the smaller graft diameters measured 2.4 cm proximally and 1.2 cm distally. The endografts were studied in 2 configurations: with the limbs straight and with one bent. RESULTS: For the larger graft model, the normal peak blood flow induced a downward force of 7 to 9 N on the bifurcated grafts. Bending one of the limbs of the graft produced a sideways force of 1.3 N. For the smaller endograft, the downward force was in the range of 3.1 to 5.1 N and the sideways force on a curved limb was approximately 1.5 N. The magnitude of the forces given by the analytical formulae and the CFD results agreed to within 2 significant figures. CONCLUSIONS: These results suggest that the downward force on a bifurcated stent-graft, which may exceed the force required to dislodge it when relying on radial attachment alone, is determined mostly by the proximal graft diameter. Curvature of the graft limbs creates an additional sideways force that works to displace the distal limbs of the graft from the iliac arteries.

Angioplasty↗

Age-related improvements in auditory backward and simultaneous masking in 6- to 10-year-old children.

This study investigated the development of auditory frequency and temporal resolution using simultaneous and backward masking of a tone by a noise. The participants were 6- to 10-year-old children and adults. On the measure of frequency resolution (the difference in the detection threshold for a tone presented either in a bandpass noise or in a spectrally notched noise), 6-year-old children performed as well as adults. However, for the backward masking task, 6-year-olds had, on average, 34 dB higher thresholds than adults. A negative exponential decay function fitted to the backward masking data for subjects of all ages indicated that adult-like temporal resolution may not be reached until about 11 years of age. These results show that, measured by masking, frequency resolution has reached adult-like performance by 6 years of age, whereas temporal resolution develops beyond 10 years of age. Six-year-old children were also assessed with tests of cognitive ability. Improvements in both frequency and temporal resolution were found with increasing IQ score.

Adult↗

Valved latex balloons and water-soluble contrast opacified polymer. Simple detachable balloon system.

Latex balloons of different shapes, sizes and volume, incorporating a simple valve mechanism, were produced cheaply. These balloons are ethylene oxide sterilized and are available on 'the shelf' for use at any time. A contrast soluble polymer consisting of 2 hydroxy-ethyl-methacrylate, a cross linker, Iopamidol and water-soluble free radical curing system has been developed. The polymer sets in 10 minutes and there is no 'dead volume' problem. The balloons and polymer were evaluated in dog arteries, including histologic studies and have been subsequently used in 7 patients without any complications.

Animals↗

Embolization of small vessels with a double-lumen microballoon catheter. Part I: Design and construction.

Existing coaxial balloon catheters cannot be passed through the smaller catheters used for superselective angiography; nor can they be used by themselves for selective catheterization, as the balloons are easily damaged. The authors describe the principles and construction of double-lumen catheters ranging from 0.45 to 0.85 mm in outer diameter, which may be passed through 4.1-6.0 F catheters to engage smaller vessels. Double-lumen catheters with an outer diameter of 0.45-0.56 mm permit injection of ethanol or a mixture of isobutyl-2-cyanoacrylate, iophendylate, and tantalum powder. The 0.85-mm size is best suited for low-viscosity silicone rubber opacified with tantalum.

Catheterization↗

Embolization of small vessels with a double-lumen microballoon catheter. Part II: Laboratory, animal, and histological studies. Work in progress.

A double-lumen microballoon catheter system measuring 0.5-0.85 mm in outer diameter (1.3-2.8 F) was fabricated for passage through standard 4.1 and 5 F catheters. By arresting circulation with the balloon, embolization with low-viscosity silicone rubber, ethanol, or isobutyl-2-cyanoacrylate can proceed in a methodical, unhurried manner, permitting precise control of tissue penetration and preventing paradoxical embolization of other vessels. Problems such as gluing the catheter in situ with cyanoacrylate did not occur. The catheter may also be inserted during surgery to control embolization at a remote site, which did result in the catheter being glued in situ in one case.

Animals↗

Angiographic findings in normal and diseased gallbladders including ischaemic cholecystitis and infarction of the gallbladder.

Angiographic studies were performed on 60 normal and diseased gallbladders obtained from cholecystectomy specimens and necropsy examinations. The normal macro and microangiographic pattern was confirmed, as was the reduction in the number of blood vessels in chronic cholecystitis and cholelithiasis. Histological correlation however showed that the degree of arteriographic change paralleled the degree of histological disease. The microvascular pattern was directly related to the degree of mucosal villous atrophy, a change which may be important in the pathogenesis of some types of gallbladder disease. The most severe angiographic changes occurred in the case of ischaemic cholecystitis, and contrasted with the normal blood vessel pattern in a case of thin walled infarction of the gallbladder.

Angiography↗

FDA's new vending code: a review.

The concept of developing and promoting the nationwide adoption of uniform sanitation regulations for food and beverage vending was agreed upon by the U.S. Public Health Service and industry leaders more than 20 years ago. Two revisions of the original Vending Code which was published in 1957 have kept pace with industry changes, the most recent now available in booklet form. Trends in food and beverage vending prompted code revisions resulting in the 1978 Vending Code which has major changes and effects on existing state and local regulations.

Food Dispensers, Automatic↗

Vending self-regulation protects foods, public health.

For 25 years, the food and beverage vending industry has protected the public health through self-regulation and standards. During that time, very few cases of foodborne illness have been reported to be caused by foods sold through vending machines. New commissary audits usher in the second 25 years of public health protection by the vending industry.

Food Dispensers, Automatic↗