PubMed Health⌕ Search

Biomedical subjects

D E Kim

Publications and source records attributed to D E Kim.

40 records · Page 3Linked to original sources

Electrophysiological improvement following decompression surgery in tarsal tunnel syndrome.

Plantar nerve conduction studies 14 months to 3.5 years after decompression surgery in 3 cases of tarsal tunnel syndrome showed an improvement in motor conduction as well as in sensory nerve conduction. This electrophysiological improvement was associated with clinical improvement. However, minor abnormalities still existed in sensory nerve conduction in all 3 cases.

Action Potentials↗

[Mercury contents in hair of dental personnel and evaluation of various agents suppressing mercury vaporization].

The purpose of the present study was to determine the mercury contents in the hair of 44 dentists and 55 hygienists as dental personnel compared with 37 male and 35 female as controls, total 171 persons in Daegu City, to compare disposable capsule with reusable capsule in their ability to suppress mercury vapour leakage during trituration and opening the capsule, and to test 4 agents (water, detergents, developer, fixer) used to suppress mercury vaporization. The results were as follows: 1. The hair mercury contents of the dental personnel (6.69 +/- 4.01 ppm) were significantly higher than those of the controls (3.03 +/- 1.62 ppm) (p less than 0.01). 2. The hair mercury contents of the hygienists (7.01 +/- 4.48 ppm) were slightly higher than those of the dentists (6.22 +/- 3.40 ppm) but not significant difference (p greater than 0.05). But hair mercury contents in the dentists and hygienists of the same period of year of exposure were 5.22 +/- 1.87 ppm, 7.01 +/- 4.48 ppm, respectively, so hair mercury contents of the hygienists were significantly higher than those of the dentists (p less than 0.05). 3. In the controls, hair mercury contents of the male (3.48 +/- 1.56 ppm) were significantly higher than those of the female (2.56 +/- 1.60 ppm) (p less than 0.05). 4. There was no correlationship between the hair mercury contents of hygienists and the period of year of exposure (r = 0.0062, p greater than 0.1) but significant correlationship in dentists (r = 0.5410, p less than 0.002). 5. Disposable capsule exhibited mercury vapour leakage during trituration and opening the capsule, 0.80 microgram, 1.97 microgram, respectively so opening the capsule was increased by 2.5 times. Reusable capsule exhibited mercury vapour leakage during trituration and opening the capsule, 0.94 microgram, 7.26 micrograms, respectively so opening the capsule was increased by 7.8 times. 6. Compared with reusable capsule, disposable capsule suppressed mercury vapour leakage during trituration and opening the capsule 1.2 times, 3.7 times, respectively. 7. Of various agents used to suppress mercury vaporization, 0.56 microgram of mercury in fixer, 0.81 microgram of mercury in developer, 0.94 microgram of mercury in detergent, 1.38 microgram of mercury in mater were released and mercury vaporization was suppressed in fixer compared with air by 12.7 times, with water by 2.5 times.

Dental Hygienists↗

Microvascular assessment of burn depth conversion during varying resuscitation conditions.

Conversion of partial- to full-thickness injuries, even after the burning has stopped, remains a significant clinical problem. We developed a rat model with a wide range of burn depths to study this phenomenon by microvascular assessment. Fifty-four male Sprague-Dawley rats weighing 460 g on average were studied. Real-time tissue monitoring of pH, paCO2, and paO2 was achieved by placement of a continuous blood gas monitor transducer in the aorta. Ten, 2-cm x 2-cm burns were created on each animal with milled aluminum templates (100 degrees C) with varying contact times. Conversion of burn depth in these wounds was documented by serial laser Doppler imager scanning over a 5-hour period. Animals received Ringer's lactate resuscitation at 0, 2, 4, 6, and 8 ml/kg/%burn. Serial laser Doppler scanning directly demonstrated progressive loss of perfusion to partial-thickness burns dependent upon the amount of fluid resuscitation. Conversion of partial- to full-thickness burns in this rat model (documented by laser Doppler microvascular assessment) was dependent upon how the animals were resuscitated.

Animals↗

The 2003 Carl A Moyer Award: real-time metabolic monitors, ischemia-reperfusion, titration endpoints, and ultraprecise burn resuscitation.

Real-time metabolic monitoring of varied vascular beds provides the raw data necessary to conduct ultraprecise burn shock resuscitation based on second-by-second assessment of regional tissue perfusion. It also illustrates shortcomings of current clinical practices. Arterial base deficit was continuously monitored during 11 clinical resuscitations of patients suffering burn shock using a Paratrend monitor. Separately, in a 30% TBSA rat burn model (N = 70), three Paratrend monitors simultaneously recorded arterial blood gas and tissue pCO2 of the burn wound and colonic mucosa during resuscitation at 0, 2, 4, 6, and 8 ml/kg/%TBSA. Paratrend data were analyzed in conjunction with previously reported laser Doppler images of actual burn wound capillary perfusion. With current clinical therapy, continuous monitoring of arterial base deficit revealed repetitive cycles of resolution/worsening/resolution during burn shock resuscitation. In the rat model, tissue pCO2 in both burn wounds and splanchnic circulation differed depending on the rate of fluid resuscitation (P <.01 between sham and 0 ml/kg/%TBSA and between 2 ml/kg/%TBSA and 4 ml/kg/%TBSA). Burn wound pCO2 values correlated well with laser Doppler determination of actual capillary perfusion (rho = -.48, P <.01). The following conclusions were reached: 1). Gratuitous and repetitive ischemia-reperfusion-ischemia cycles plague current clinical therapy as demonstrated by numerous "false starts" in the resolution of arterial base deficit; 2). in a rat model, real-time monitoring of burn wound and splanchnic pCO2 demonstrate a dose-response relationship with rate of fluid administration; and 3). burn wound and splanchnic pCO2 are highly correlated with direct measurement of burn wound capillary perfusion by laser Doppler imager. Either technique can serve as a resuscitation endpoint for real-time feedback-controlled ultraprecise resuscitation.

Acid-Base Equilibrium↗