Fluorine-18-FPCT: a PET radiotracer for imaging dopamine transporters.

UNLABELLED: Fluorine-18-labeled 2 beta-carbomethoxy-3 beta-(4-chlorophenyl)-8-[-3-fluoropropyl) nortropane (FPCT) has been synthesized as a new dopamine transporter imaging agent. METHODS: Fluorine-18 was introduced into 2 beta-carbomethoxy-3 beta-(4-chlorophenyl)-8-[-3-fluoropropyl) nortropane by preparation of 1-[18F]fluoro-3-iodopropane followed by alkylation of 2 beta-carbomethoxy-3 beta-(4-chlorophenyl)nortropane. RESULTS: Tissue distribution studies in rats with [18F]FPCT showed high striatal uptake (0.70% dose/g at 60 min; 0.38% dose/g at 120 min) and good striatal-to-cerebellum ratios (5.5 at 60 min; 6.2 at 120 min). Imaging studies in rhesus monkeys (n = 2) with [18F]FPCT showed high uptake and retention in the putamen (P) (P = 0.03%-0.12% dose/g; at 115 min) and good putamen-to-cerebellum ratios of 3.40-3.43 at 115 min. Plasma metabolites were analyzed in rhesus monkeys (n = 2) by ether extraction and HPLC. The radioactivity in the ether-extractable fraction displayed a single peak that corresponded on HPLC to unmetabolized authentic FPCT. CONCLUSION: These results suggest that [18F]FPCT is an excellent candidate for PET imaging of dopamine transporters.

Animals

Early stage melanoma: lymphoscintigraphy, reproducibility of sentinel node detection, and effectiveness of the intraoperative gamma probe.

PURPOSE: To assess the influence of lymphoscintigraphic and intraoperative gamma probe findings on the surgical management of melanoma and to test reproducibility of lymphoscintigraphic findings. MATERIALS AND METHODS: After lymphoscintigraphic identification of the sentinel node, intraoperative gamma probe localization and sentinel lymph node excision were performed in 25 patients. To assess reproducibility, 13 patients underwent lymphoscintigraphy twice within 2-17 days. A modified preparation of technetium-99m sulfur colloid with smaller particles than routinely obtained was injected intradermally around the lesion. Dynamic flow images were obtained at 10 seconds per frame followed by a series of static images obtained every 5 minutes for 30 minutes. RESULTS: A sentinel node was identified in all patients. In eight patients, multiple drainage pathways were seen and surgical management was changed. In 11 of the 13 who underwent lymphoscintigraphy twice, sentinel node identification was reproducible. CONCLUSION: Lymphoscintigraphy is reproducible in detection of the sentinel node and with the surgical probe helps effectively guide surgical management.

Female

Technetium-99m-sulfur colloid for lymphoscintigraphy: effects of preparation parameters.

UNLABELLED: There has been a resurgence in the use of lymphoscintigraphy for the external detection of lymph nodes for metastatic melanoma and breast tumors. Technetium-99m-antimony trisulfide colloid was the radiopharmaceutical developed for this procedure and was found to have a narrow distribution of small particles, 0.003-0.03 microns, but it was never approved by the FDA. Technetium-99m-sulfur colloid also forms particles and this article reports on the effects different preparation parameters have on its particle size distribution and stability. METHODS: Four groups of kits were evaluated, kits which utilized: (a) a reduced heating protocol with a new 99mTc-elution, (b) a reduced heating protocol with an old 99mTc-elution, (c) a prolonged heating protocol with a new 99mTc-elution and (d) a prolonged heating protocol with an old 99mTc-elution. The particle size distribution and the stability of the different 99mTc-sulfur colloid kit preparations were evaluated over 6 hr utilizing polycarbonate filters ranging from 0.03 to 10 microns. RESULTS: In vitro studies demonstrated no significant change in the particle size distribution over a 6-hr period and all 99mTc-sulfur colloid preparations had a bimodal particle size distribution pattern. Importantly, heating the kit for shorter periods of times utilizing [99mTc]pertechnetate, which had a longer ingrowth of [99mTc]pertechnetate, produced a formulation which had the largest percentage of particles smaller than 0.03 microns. CONCLUSION: In our clinical setting, 99mTc-sulfur colloid prepared with the reduced heating protocol and utilizing [99mTc]pertechnetate, which has the highest ingrowth of [99mTc]pertechnetate has proved to be an excellent agent for lymphoscintigraphy studies. This preparation has demonstrated rapid movement of the particles from the primary site to the lymph nodes in over 97% (106/109) of the patients we have studied.

Humans

Measuring technetium-99m-MAG3 clearance with an improved camera-based method.

UNLABELLED: Because commercially available camera-based methods are not optimized, they fail to account for dose infiltration, table attenuation and correspondence between time of injection and starting the camera. We have developed a more optimized technique to calculate camera-based clearances and applied this technique in the design of a camera-based clearance method for 99mTc-MAG3. METHODS: Technetium-99m-MAG3 scintigraphy was performed in 20 patients who had varying degrees of renal function. Data were acquired posteriorly in supine patients at 2 sec/frame for 24 frames, 15 sec/frame for 16 frames and 30 sec/frame for 40 frames. Background correction was performed using an automated elliptical region of interest. Renal depth was estimated using improved regression equations and an empirically determined attenuation coefficient derived from phantom studies. Corrections were made for table attenuation and time discrepancies between dose injection and starting the camera. The percent injected dose in the kidney at 1-2, 1-2.5 and 2-3 min postinjection and the percent injected dose at those time periods corrected for body surface area were correlated with MAG3 clearance based on a single injection, two-compartment model. RESULTS: There was high correlation between the percent injected dose in the kidney at all three time periods and the multisample clearance. Correcting for body surface areas significantly improved the correlation coefficients. Consequently, regression equations were developed to predict multisample clearance based on percent dose and body surface area. CONCLUSION: The optimization features described in this method should improve precision when sequential studies are conducted in the same patient.

Adult

Renal artery stenosis and ischemia. Effect on renal blood flow and extraction fraction.

The clearance of [131I]orthoiodohippurate and 99mTc-mercaptoacetyltriglycine provide a measure of effective renal plasma flow, yet these clearances are proportional to renal plasma flow only if the extraction fraction remains constant. To determine the effect of unilateral renal artery stenosis, captopril, renal ischemia, and partial renal vein occlusion on renal blood flow and the extraction fraction of [131I]orthoiodohippurate, 99mTc-mercaptoacetyltriglycine, and [125I]iothalamate, we conducted a series of constant infusion studies in Sprague-Dawley rats. Renal artery flow reduction of approximately 70% decreased the extraction fraction of all three agents (P < or = .05). Captopril had no effect on extraction fraction in controls, but it produced a further decrease in extraction fraction of 99mTc-mercaptoacetyltriglycine and [131I]orthoiodohippurate in rats with renal artery stenosis (P < or = .05). Ischemia resulted in a 16% decrease in flow (P < .01) but a much larger (47% to 65%) decrease in extraction fraction of all three agents (P < .002). Partial renal vein occlusion also decreased the extraction fraction of all three agents (P < or = .05). The changes in extraction fraction imply that the clearances of [131I]orthoiodohippurate and 99mTc-mercaptoacetyltriglycine in disease states may not be proportional to renal plasma flow. Furthermore, in rats with renal artery stenosis it appears that renal blood flow must fall below a critical threshold of approximately 58% before extraction fraction decreases; as renal blood flow is further reduced below this threshold, there is a corresponding reduction in extraction fraction (P < .01).

Animals

Evaluation of technetium-99m-triamide-mercaptide complexes designed to identify properties favoring renal tubular transport.

UNLABELLED: To aid in the design of an improved 99mTc-labeled renal agent, several new [99mTcO(MAG3)]2- analogs were synthesized to determine the effects of varying the position and chemical form of the terminal charged group on renal clearance. METHODS: Clearance, extraction efficiency and plasma protein binding were measured in six Sprague-Dawley rats per complex for ortho, meta and para isomers of [99mTcO(MAG2-ABA)]2-, with MAG2- = mercaptoacetylglycylglycyl- and ABA = aminobenzoate; [99mTcO(MAG2-pASA)]2-, with pASA = p-aminosalicylate; [99mTcO(MAG2-AMS]2-, with AMS = aminomethylsulfonate; and [99mTcO(MAG2-AMP]3-, with AMP = aminomethylphosphonate. For agents with relatively poor clearances, hepatobiliary excretion was evaluated by using a camera-based method. RESULTS: The clearances of the ortho, meta and para isomers of [99mTcO(MAG2-ABA)]2- were 17%, 20% and 59% of those of OIH, respectively. The clearances of [99mTcO(MAG2-pASA)]2-, [99mTcO(MAG2-AMS)]2- and [99mTcO(MAG2-AMP)]3- were 32%, 46% and 39% those of OIH, respectively. CONCLUSION: Optimal tubular transport appears to require a terminal anionic group; a planar carboxylate is preferred over nonplanar -SO3- or -PO3(2-) substituents, suggesting that the smaller size and/or planar shape of the carboxylate group are probably more important than the total charge or charge distribution. Optimal transport also appears to depend on the oxo-carboxylate conformation (syn or anti) and the oxo-carboxylate distance, although these relationships can be modulated by steric interactions. These structure-distribution relationships are important factors to consider in the future design of renal radiopharmaceuticals.

Animals

Evaluation of the hepatobiliary excretion of technetium-99m-MAG3 and reconstitution factors affecting radiochemical purity.

UNLABELLED: Technetium-99-MAG3 is a renal tubular function agent. However, sporadic liver and gallbladder visualization have raised questions about kit stability, impurities and nonrenal routes of excretion. To address these issues, studies were conducted to optimize the labeling efficiency of the TechneScan MAG3 kit and to evaluate the hepatobiliary excretion of the MAG3 complex. METHODS: Thirty-six vials of the commercial formulation of 99mTc-MAG3 were prepared according to manufacturer's instructions and evaluated for radiochemical purity using two methods: a combination of high-performance liquid chromatography and paper chromatography (HPLC/PC); and the manufacturer's miniature chromatography system (Sep-Pak procedure). RESULTS: The labeling efficiency was significantly higher when the kit was reconstituted with 10 ml (96.6%) of saline versus 5 ml (91.4%) (p < 0.01). The radiochemical purity of the kits remained stable for up to 6 hr, but the purity determined by Sep-Pak averaged 2.5% higher than that determined by HPLC procedures (p < 0.01). Rat studies to evaluate renal and hepatobiliary elimination of MAG3 showed no difference in the %ID excreted into the urine by 60 min in all groups of animals studied. However, the %ID excreted into the bile was significantly higher for the kit formulation than the HPLC-purified MAG3, 9.9% versus 6.6% (p = 0.0475). CONCLUSION: The radiochemical purity of the TechneScan MAG3 kit can be improved by reconstituting with larger volumes. In addition, the studies in rats suggest that fasting or kit impurities may be a contributing factor to increased hepatobiliary visualization in patient studies.

Animals

Biological distribution of 99mTc-labeled YIGSR and IKVAV laminin peptides in rodents: 99mTc-IKVAV peptide localizes to the lung.

Two laminin-derived peptides containing either YIGSR or IKVAV (single amino acid code) sequences were radiolabeled with 99mTc and their biological distribution evaluated in rodents. Both 99mTc-peptides cleared rapidly from the circulation though the kidney, and to a lesser extent, through the liver. 99mTc-YIGSR peptide did not accumulate in any organ examined in normal, tumored, and emphysemic mice. The 99mTc-IKVAV peptide localized within 10 min to the lung of normal animals, resulting in lung-to-blood ratios of approximately 23:1. The 99mTc-IKVAV peptide localized to lung after submicron filtration and after intraperitoneal injection, suggesting that particulates do not major role in localization. Pre-incubation of 99mTc-IKVAV peptide in whole blood decreased lung localization, suggesting that margination of radiolabeled cells does not play a major role in the lung localization. When 99mTc-IKVAV was injected into mice with tumored lungs (melanoma), the lung uptake was markedly increased (up to 20% injected dose higher than control lungs) at all time points examined (10, 30, and 120 min). When 99mTc-IKVAV was injected into mice with genetic emphysema, the lung uptake was markedly decreased at all time points. The localization of the 99mTc-IKVAV-containing peptide to the lung is consistent with a receptor-based mechanism.

Amino Acid Sequence

Enhanced tumor imaging with pokeweed mitogen.

Traditional tumor imaging with biotracer techniques relies solely on the target specificity of the biomolecule. We hypothesize that specific imaging is possible by altering the rate of tissue clearance (both normal and aberrant) of any given radiotracer. Pokeweed mitogen (PWM) as a biomodulator, represents a class of molecules which regulate cellular differentiation and cell-cell interactions and, as part of these mechanisms alter tissue clearance rates (both normal and aberrant). Utilizing the B-16/C57BL/6 model, 7 days post-transplantation (which represents log phase growth of the tumor), 10 animals were imaged following an i.v. injection of 1-2 mCi 99mTc-PWM in order to visualize the tumors and determine the optimal imaging kinetics. A specific tumor image is achieved between 120 and 240 min post-injection. In addition, tumor imaging studies using a non-tumor-specific biomolecule were conducted by injecting 19 animals i.v. with 1-2 mCi of 99mTc-human serum albumin (HSA). Twelve of these animals were given 10 micrograms of PWM i.p. at various intervals prior to the 99mTc-HAS administration. Imaging and biodistribution studies were performed at various intervals up to 2 h post-99mTc-HSA injection. A 32-59% increase in the tumor-to-muscle ratio was observed in the PWM-treated animals relative to the non-treated controls. To further investigate the PWM-induced tissue clearance alteration hypothesis, tissue clearance studies using 99mTc-diethylenetriaminepentaacetic acid (DTPA) were conducted in non-tumor bearing ICR mice and the B-16/C57BL/6 tumor bearing animals. 99mTc-DTPA normal tissue clearance rates were significantly increased in the PWM treated animals relative to the non-treated controls.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals

Technetium-99m (99mTc) mercaptoacetyltriglycine: update on the new 99mTc renal tubular function agent.

Technetium-99m (99mTc) mercaptoacetyltriglycine (MAG3) is a new renal radiopharmaceutical that was recently introduced as a 99mTc-labeled replacement for iodine-131 (131I) o-iodohippurate (OIH). Since its introduction, a wide variety of in vitro and in vivo studies have been performed to characterize the high-performance liquid chromatography (HPLC)-purified complex and kit formulations. [99mTc]MAG3 has a slower plasma clearance, a higher plasma protein binding, less red blood cell (RBC) penetration, a lower extraction ratio, and a smaller volume of distribution than OIH. Because of the slower plasma clearance, [99mTc] MAG3 cannot be used as a direct measurement of effective renal plasma flow. Simplified methods have been developed to calculate [99mTc]MAG3 clearances, as well as regression equations to convert these clearances to an equivalent OIH value. The image quality of [99mTc]MAG3 is superior to [131I]OIH; the renogram curves and the fraction of the dose of the two agents that appears in the urine are almost identical, even though the plasma clearance of [99mTc]MAG3 is only 50% to 65% that of OIH. [99mTc]MAG3 compares favorably with OIH in patients with a wide range of clinical problems. The radiation dose to a patient with normal renal function using standard imaging doses is higher for [99mTc]MAG3 than for [131I]OIH, but in patients with impaired renal function, the radiation dose from [131I]OIH is much higher than [99mTc]MAG3. [99mTc]MAG3 also provides superior image quality compared with [99mTc]diethylenetriaminepentaacetic acid (DTPA) in patients with impaired renal function, but it is important to note that [99mTc]MAG3 cannot be used to measure the glomerular filtration rate (GFR). [99mTc]MAG3 is the most promising 99mTc tubular function agent to date, and it has replaced OIH and [99mTc]DPTA in a number of institutions. However, there are physiologic differences between these three agents and, therefore, they should not be expected to behave identically in all clinical conditions.

Animals

Prospective validation of a single sample technique to determine technetium-99m-MAG3 clearance.

Technetium-99m-MAG3 clearance is proportional to OIH clearance and can be used directly as a measure of renal function. Multiple plasma sample, two-compartment clearance data from three studies were recently pooled to develop a single-sample regression equation for determining the clearance of 99mTc-MAG3. To test this published equation, a prospective study was conducted in 34 patients with a wide range of renal function. Multiple plasma samples were obtained from 9 to 60 min following the bolus injection of 99mTc-MAG3 and the clearances were calculated based on a single injection, two-compartment model. Clearances were also calculated using a single 43-min plasma sample and the published regression equation. There was an excellent correlation (r = 0.976) between the two clearances; the slope of the regression line was 1.01 with an intercept of -26.6; the standard error of the estimate was 24 ml/min. In conclusion, the current regression equation provides a good estimate of 99mTc-MAG3 clearance.

Chromatography, High Pressure Liquid

Radiation dosimetry for technetium-99m-MAG3, technetium-99m-DTPA, and iodine-131-OIH based on human biodistribution studies.

Radiation dose estimates were calculated for the renal agents 99mTc-DTPA, 99mTc-MAG3, and 131I-OIH from biodistribution data gathered in groups of healthy human volunteers. Biokinetics were evaluated by Anger camera imaging, blood sampling, and urine collection and counting. Collected data were fit to four- or five-compartmental models using the CONversational Simulation, Analysis, and Modeling (CONSAM) software. Radiation dose estimates were performed using standard MIRD techniques. Average residence times in urinary bladder, kidney, and remainder of the body were used to predict radiation dose equivalents and effective dose equivalents for the three agents. Doses for DTPA and MAG3 were very similar and much lower on a per unit injected activity than OIH. The effective dose equivalents were 3.3 mSv/370 MBq for 99Tc-DTPA, 3.7 mSv/370 MBq for 99mTc-MAG3, and 0.99 mSv/11.1 MBq for 131I-OIH for bladder voiding every 4.8 hr; effective dose equivalents were 2.0 mSv/370 MBq for 99mTc-DTPA, 1.5 mSv/370 MBq for 99mTc-MAG3, and 0.28 mSv/11.1 MBq for 131I-OIH for bladder voiding at 30 min and then every 4.0 hr. Patients should void at the conclusion of the study, as early voiding can reduce the gonadal radiation dose by a factor of 2 to 3.

Humans

Effect of advanced age on p-aminohippurate-induced inhibition of renal tubular secretion in male Fischer 344 rats.

The effect of aging on glomerular filtration, effective renal plasma flow and on the responsiveness of the renal tubular anion secretory system to inhibition by 4-aminobenzoylglycine (p-aminohippurate, PAH) was examined in young (5-month) and old (22-month) Fischer 344 male rats. Plasma clearance, protein binding and renal extraction of [131I]o-iodohippurate, [125I]iothalamate and HPLC-purified [99mTc]mercaptoacetyltriglycine (MAG3), were used as in vivo probes of renal function. The effect of advanced age, without concomitant PAH, on the disposition of these markers was initially determined in ketamine anesthetized, temperature-maintained male rats, ages 5, 14 and 22 months by means of constant infusion clearance studies. Aging per se decreased (P less than 0.05) the kidney-weight normalized or body weight-normalized GFR and effective renal plasma flow rates. GFR values averaged 1.67, 1.43 and 1.32 ml/min per g kidney for the 5-, 14- and 22-month-old rats, respectively. Kidney- or body weight-normalized clearances of MAG3 and o-iodohippurate showed similar (25-27%) decreases, whereas the absolute values (ml/min) for GFR, o-iodohippurate and MAG3 clearance rates were not altered by aging. The effective filtration fraction, extraction ratio and plasma protein binding were also unchanged by advanced age. Overall, the age-related decreases in renal function were minimal in Fischer-344 rats, compared to other species. Differences in data normalization, species and gender account, in part, for discrepancies observed when comparing results in different studies on the effects of advanced age on renal function. Subsequently, we examined the effect of aging on the renal responsiveness to inhibition of tubular anion secretion using constant rate PAH infusion studies, adjusted for age-related changes in renal function. Aging did not alter PAH-induced inhibition of iodohippurate secretion. Inhibition of MAG3 elimination was more pronounced in the old rats compared to the young controls.

Aging

99mTc renal tubular function agents: current status.

Orthoiodohippuric (OIH) acid labeled with 131I is a widely used renal radiopharmaceutical agent and has been the standard radiopharmaceutical agent for the measurement of effective renal plasma flow (EPRF). Limitations to the routine clinical use of 131I OIH are related to the suboptimal imaging properties of the 131I radionuclide and its relatively high radiation dose. 123I has been substituted for 131I; however, its high cost and short shelf-life have limited its widespread use. Recent work has centered on the development of a new 99mTc renal tubular function agent, which would use the optimal radionuclidic properties and availability of 99mTc and combine the clinical information provided by OIH. The search for a suitable 99mTc renal tubular function agent has focused on the diamide dithiolate (N2S2), the paraaminohippuric iminodiacetic acid (PAHIDA), and the triamide mercaptide (N3S) donor ligand systems. To date, the most promising 99mTc tubular function agent is the N3S complex: 99mTc mercaptoacetyltriglycine (99mTc MAG3). Studies in animal models in diuresis, dehydration, acid or base imbalance, ischemia, and renal artery stenosis demonstrate that 99mTc MAG3 behaves similarly to 131I OIH. A simple kit formulation is available that yields the 99mTc MAG3 complex in high radiochemical purity. Studies in normal subjects and patients indicate that 99mTc MAG3 is an excellent 99mTc renal tubular agent, but its plasma clearance is only 50% to 60% that of OIH. In an effort to develop an improved 99mTc renal tubular function agent, changes have been made in the core N3S donor ligand system, but to date no agent has been synthesized that is clinically superior to 99mTc MAG3.

Aminohippuric Acids

Comparison of Tc-99m MAG3 and Tc-99m DTPA in renal transplant patients with impaired renal function.

Tc-99m mercaptoacetyltriglycine (MAG3) is a new Tc-99m renal agent that compares favorably to I-131 Hippuran in animal models, normal volunteers, and patients. Based on the fact that Tc-99m MAG3 has a much more rapid clearance than Tc-99m DTPA and a smaller volume of distribution, it was postulated that the image quality of Tc-99m MAG3 studies should be superior to scans obtained using Tc-99m DTPA, particularly in patients with impaired renal function. To test this hypothesis, Tc-99m DTPA and MAG3 images were obtained in three transplant patients during periods of stable but impaired renal function. In one study, the Tc-99m DTPA study was potentially misleading, whereas the Tc-99m MAG3 examination assessed the clinical situation correctly. In all three cases, the Tc-99m MAG3 images were superior.

Adult