PubMed Health⌕ Search

Biomedical subjects

D F Guthaner

Publications and source records attributed to D F Guthaner.

At least 37 records · Page 2Linked to original sources

Clinical application of hybrid subtraction digital angiography: preliminary results.

The clinical application of hybrid subtraction in digital fluoroscopy of the vasculature is reported in our first 30 patients studied. Hybrid subtraction combines the advantages of temporal and dual energy subtraction techniques to achieve simultaneous elimination of overlying bone, soft tissue, and motion induced artifacts. Hybrid subtraction improved the subjective appearance of an image in 19 of 30 (63%) studies but additional diagnostic information was only revealed in 11 of 30 (37%) patients.

Angiography↗

Baseline subtraction in quantitative cardiovascular computed tomography.

Beam-hardening (BH) effect was evaluated to determine its potential significance in quantitative blood flow measurements using computed tomography (CT). CT scans of a water bath containing a range of concentrations of iodine (0-15 mg/ml) placed outside and within the chest of a dead dog were obtained at different kVp levels (100, 120, and 130 kVp). The mean CT number and standard deviation were measured over a small region of interest for each concentration. The CT numbers measured outside the chest were significantly higher (p less than 0.01) than those measured inside, suggesting a BH effect. However, this BH error was almost eliminated (p greater than 0.01) when water values (CTw) were subtracted from the CT numbers of the iodine solutions (delta CT = CT1 - CTW). Water subtraction was used to simulate baseline tissue CT numbers prior to contrast enhancement so that the delta CT values were analogous to those generally used to analyze blood flow. The BH effect was therefore not found to be significant for blood flow measurement accuracy in cardiovascular CT.

Animals↗

Evaluation of peripheral vascular disease using digital subtraction angiography.

Intravenous digital subtraction angiography (DSA) facilitates imaging of peripheral arteries and bypass grafts on an outpatient basis. Forty-five patients underwent intravenous peripheral angiography, 16 following placement of bypass grafts. Complex oblique and sagittal angulations optimize visualization of bifurcations and overlapping vascular structures. Reprocessing techniques using integrated masks and contrast images allow for diagnostic delineation of fine vascular detail. This is a practical, noninvasive, well tolerated method for both diagnostic screening and follow-up evaluation of patients with peripheral vascular disease.

Angiography↗

Digital subtraction angiography of aortic dissection.

Digital subtraction angiography (DSA) was used to study six patients with aortic dissection, five of whom had undergone surgical repair. One patient had both pre- and postoperative evaluations. DSA with intravenous contrast administration is a relatively noninvasive procedure that provides diagnostic images in projection format allowing assessment of the extent of aortic dissection and involvement of important aortic branches. Postacquisition reprocessing techniques unique to DSA optimize the imaging information regarding flow dynamics of the true and false channels.

Aortic Dissection↗

Intravenous arteriography using digital subtraction techniques.

The application of digital computers to electronic x-ray imaging devices has rejuvenated interest in the field of intravenous arteriography. By utilizing computer image subtraction techniques, digital roentgenographic systems based on fluoroscopy or computed tomography (scanned projection radiography) provide significantly improved vascular imaging compared with conventional film subtraction methods. Digital subtraction angiography schemes isolate contrast media in the vessel by detecting differences in images obtained before and after the injection of contrast medium or changes in the relative attenuation of contrast media at different x-ray energies. Present applications include carotid and peripheral arteriography, thoracic and abdominal aortography, pulmonary arteriography, and ventriculography. Future applications may include intracerebral and coronary arteriography. These systems should provide low-risk outpatient screening arteriography.

Angiography↗

Spontaneous dissection of the ascending aorta diagnosed by two-dimensional echocardiography.

In two patients with acute dissection of the ascending aorta, the diagnosis was made with two-dimensional echocardiography and confirmed by aortography. The echocardiograms localized the intimal flap and false channel in both cases. Although clinical evaluation and indicated radiologic studies remain the primary modalities of diagnosis in acute aortic dissection, two-dimensional echocardiography may be a useful additional diagnostic technique.

Adult↗

The use of computed tomography in the diagnosis of coronary artery bypass graft patency.

In a preliminary evaluation of the use of dynamic computed tomography (CT) for the detection of patent aortocoronary bypass grafts, 30 patients were scanned either during the early postoperative period or after graft patency was determined by angiography. To visualize the proximal grafts, CT scans were taken through the aortic root following an intravenous bolus injection of contrast medium. Patent bypass grafts to the left anterior descending and right coronary arteries were demonstrated in 77.5%, while posterior grafts to the circumflex and obtuse marginal coronary arteries were detected in 40%. With its potential for extracting dynamic events, CT scanning provides a new, noninvasive modality for the diagnosis of patent bypass grafts, which heretofore have only been visualized by selective angiography.

Adult↗

Coronary hemodynamic effects of ergonovine maleate in human subjects.

The coronary hemodynamic effects of ergonovine maleate were examined in 15 patients with a chest pain syndrome not thought to be variant angina. Ergonovine was given intravenously in sequential doses of 0.05, 0.1 and 0.25 mg while measurements were made of systemic hemodynamic variables, coronary sinus blood flow and coronary arteriovenous oxygen difference at intervals during the protocol. Coronary arterial diameters were measured from the 35 mm cineangiogram. Despite an increase in myocardial metabolic demand, as estimated with the heart-rate-blood pressure product, there was no apparent increase in coronary vascular resistance. In addition, there was a significant widening of the coronary arteriovenous oxygen difference in five of the seven patients in whom it could be measured. However, neither chest pain nor ischemic electrocardiographic changes were evoked. Although ergonovine also produced a diminution in epicardial coronary arterial diameters, this effect was not sufficient to explain the absence of appropriate coronary vasodilation. These results suggest that ergonovine may limit the normal vasodilatory response of the arteriolar bed to increases in myocardial metabolic demand.

Adult↗

Gated cardiac computed tomography with a motion phantom.

CT images of the heart are significantly degraded by the effects of motion during the scanning interval. The use of electrocardiographic (ECG) gating to provide "stop-action" cardiac images remains limited by artifacts. A motion phantom has been constructed to allow systematic study of the artifact structure of ECG-gated images and to isolate the origins of these artifacts. "Stop-action" reconstructed images are presented demonstrating two classes of artifacts: (a) pinwheel artifacts that appear at the edges of high-contrast moving objects; and (b) linear streaks occurring in relation to missing views when an incomplete angular set of projections is used for image reconstruction with the convolution back-projection algorithm. These results underscore the use of the motion phantom for the analysis of image artifacts and stress the need for new CT reconstruction algorithms which are optmized for "stop-action" scanning.

Heart↗

New aspects of coronary angiography.

By combining the standard oblique projections used in coronary arteriography with sagittal or axial angulation of the x-ray beam in relation to the heart, the information provided by this study can be significantly enhanced. This approach is especially useful in assessing the patency of coronary artery bypass grafts.

Coronary Angiography↗

Altered adrenergic activity in coronary arterial spasm: insight into mechanism based on study of coronary hemodynamics and the electrocardiogram.

To elucidate the pathophysiologic mechanism of coronary arterial spasm, the hypothesis was examined that underlying alterations in sympathetic activity may account for this syndrome in some patients. Observations were directed to alterations in coronary arterial hemodynamics and the electrocardiogram. Spasm of the left anterior descending coronary artery produced a mean increase in coronary vascular resistance of 107 percent (P less than 0.05) in four patients in whom coronary sinus blood flow was measured with the thermodilution technique. The alpha adrenergic blocking agent phentolamine, given intravenously, acutely reversed coronary spasm and its clinical manifestations in eight patients and reduced coronary resistance. In four patients, administration of the long-acting oral alpha blocking agent phenoxybenzamine (20 to 80 mg/day) caused disappearance of symptoms during a follow-up period of 3 to 12 months. Transient prolongation of the corrected Q-T interval preceded spontaneous or ergonovine maleate-provoked coronary spasm in 11 patients with variant angina pectoris, whereas no significant change in the Q-T interval followed ergonovine administration in 27 control patients with atypical chest pain who did not have coronary spasm. T wave inversions in the resting electrocardiogram were normalized by isoproterenol infusion in one patient and by long-term phenoxybenzamine treatment in four patients with variant angina pectoris. These Q-T and T wave changes are analogous to those described with unilateral or asymmetric stellate ganglion stimulation in animals. These observations suggest that alterations in the sympathetic nervous system that are consistent with asymmetric stellate ganglion activity and transient alpha adrenergic receptor stimulation can presage the development of coronary arterial spasm in some patients with variant angina pectoris.

Adult↗

Fate of the false lumen following surgical repair of aortic dissections: an angiographic study.

Postoperative angiography was performed in 27 patients who had surgical repair for aortic dissections. The ascending aorta was involved in 22 dissections (Type A), while in five dissections it was uninvolved (Type B). Findings were assessed between two weeks and 13 years postoperatively. Despite the primary surgical objective to abolish flow in the false lumen, the majority of patients, whether symptomatic or not, continued to harbor patent distal false channels. In certain cases, one or more vital aortic branches were perfused solely by the false lumen. Initial postoperative angiography is indicated for determined surgical results as well as the functional significance of late angiographic findings, should symptoms recur. Further extension of the initial dissection, redissection, or enlargement of localized saccular aneurysms may mandate late reoperation. These conditions manifest themselves by pain, aortic regurgitation, neurological sequelae, or compromise of blood flow to a vital organ or extremity.

Aortic Dissection↗