Lab-on-a-chip: a revolution in biological and medical sciences
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to D Figeys.
Explore the source record for details and available documents.
The combination of microfabricated fluidic systems (muFAB) and electrospray mass spectrometers (ESI-MS) will provide multiplexed and integrated analytical systems for proteins and other biomolecules. Implementation of this novel approach requires the development of robust and user-friendly muFAB devices. Here, we present new approaches that improve the robustness, user friendliness and performance of muFAB devices coupled to MS. First, we present the development of a convenient mount to connect a muFAB device to the ESI-MS and the incorporation of filters in the reservoirs and exit of the muFAB. This mount facilitates interfacing and significantly reduces the chemical noise observed by the MS. Furthermore, we demonstrate improvements in sample handling and delivery by using either a nonaqueous electrolyte or a cationic coating on the surfaces in the muFAB device and transfer capillary. These improvements are applied to protein analysis by continuous infusion of proteolytic digests.
Endothelial cells release nitric oxide (NO) acutely in response to increased laminar fluid shear stress, and the increase is correlated with enhanced phosphorylation of endothelial nitric-oxide synthase (eNOS). Phosphoamino acid analysis of eNOS from bovine aortic endothelial cells labeled with [(32)P]orthophosphate demonstrated that only phosphoserine was present in eNOS under both static and flow conditions. Fluid shear stress induced phosphate incorporation into two specific eNOS tryptic peptides as early as 30 s after initiation of flow. The flow-induced tryptic phosphopeptides were enriched, separated by capillary electrophoresis with intermittent voltage drops, also known as "peak parking," and analyzed by collision-induced dissociation in a tandem mass spectrometer. Two phosphopeptide sequences determined by tandem mass spectrometry, TQpSFSLQER and KLQTRPpSPGPPPAEQLLSQAR, were confirmed as the two flow-dependent phosphopeptides by co-migration with synthetic phosphopeptides. Because the sequence (RIR)TQpSFSLQER contains a consensus substrate site for protein kinase B (PKB or Akt), we demonstrated that LY294002, an inhibitor of the upstream activator of PKB, phosphatidylinositol 3-kinase, inhibited flow-induced eNOS phosphorylation by 97% and NO production by 68%. Finally, PKB phosphorylated eNOS in vitro at the same site phosphorylated in the cell and increased eNOS enzymatic activity by 15-20-fold.
Electrospray ionization (ESI) tandem mass spectrometry (MS/MS) of peptides in conjunction with automated sequence database searching of the resulting collision-induced dissociation (CID) spectra has become a powerful method for the identification of purified proteins or the components of protein mixtures. The success of the method is critically dependent on the manner by which the peptides are introduced into the mass spectrometer. In this report, we describe a capillary electrophoresis-based system for the automated, sensitive analysis of complex peptide mixtures. The system consists of an ESI-MS/MS instrument, a solid-phase extraction (SPE)-capillary zone electrophoresis (CZE) device for peptide concentration and separation, and an algorithm written in Instrument Control Language (ICL) which modulates the electrophoretic conditions in a data-dependent manner to optimize available time for the generation of high-quality CID spectra of peptides in complex samples. We demonstrate that the data-dependent modulation of the electric field significantly expands the analytical window for each peptide analyzed and that the sensitivity of the SPE-CZE technique is not noticeably altered by the procedure. By applying the technique to the analysis of in vivo phosphorylation sites of endothelial nitric oxide synthase (eNOS), we demonstrate the power of this system for the MS/MS analysis of minor peptide species in complex samples such as phosphopeptides generated by the proteolytic digestion of a large protein, eNOS, phosphorylated at low stoichiometry.
The comprehensive analysis of biological systems requires a combination of genomic and proteomic efforts. The large-scale application of current genomic technologies provides complete genomic DNA sequences, sequence tags for expressed genes (EST's), and quantitative profiles of expressed genes at the mRNA level. In contrast, protein analytical technology lacks the sensitivity and the sample throughput for the systematic analysis of all the proteins expressed by a tissue or cell. The sensitivity of protein analysis technology is primarily limited by the loss of analytes, due to adsorption to surfaces, and sample contamination during handling. Here we summarize our work on the development and use of microfabricated fluidic systems for the manipulation of minute amounts of peptides and delivery to an electrospray ionization tandem mass spectrometer. New data are also presented that further demonstrate the potential of these novel approaches. Specifically, we describe the use of microfabricated devices as modules to deliver femtomole amounts of protein digests to the mass spectrometer for protein identification. We also describe the use of a microfabricated module for the generation of solvent gradients at nl/min flow rates for gradient chromatography-tandem mass spectrometry. The use of microfabricated fluidic systems reduces the risk of sample contamination and sample loss due to adsorption to wetted surfaces. The ability to assemble dedicated modular systems and to operate them automatically makes the use of microfabricated systems attractive for the sensitive and large-scale analysis of proteins.
We describe an integrated analytical system consisting of a microfluidics device micromachined using photolithography/etching technology, a panel of computer-controlled high-voltage relays, and an electrospray ionization tandem mass spectrometer. Movement of solvents and samples on the device and off the device to the mass spectrometer was achieved by directed electroosmotic pumping induced by the activation of a suitable constellation of high-voltage relays. The system was used for the sequential automated analysis of protein digests. We demonstrate low femtomole per microliter sensitivity of detection and compatibility of the system with the automated analysis of proteins separated by two-dimensional gel electrophoresis.
Microfabrication technology offers the opportunity to construct microfluidic modules which are designed to perform specific, dedicated functions. Here we report the construction of a microfabricated device for the generation and delivery by electroosmotic pumping of solvent gradients at nanoliter per minute flow rates. The device consists of three solvent reservoirs and channels which were etched in glass. Solvent gradients and solvent flows were generated by computer controlled differential electroosmotic pumping of aqueous and organic phase, respectively, from the solvent reservoirs. The device was integrated into an analytical system consisting of the solvent gradient delivery module, a reverse phase microcolumn and an electrospray ionization ion trap mass spectrometer (MS). The system was used for the analysis at high sensitivity of peptides and peptide mixtures generated by proteolytic digestion of proteins. We have measured an absolute limit of detection as low as 1 fmol and a concentration limit of detection at the 100 amol/microL level. The system was also successfully used for the identification of proteins separated by 1D and 2D gel electrophoresis. This was achieved by gradient frontal analysis of the peptide mixture generated by proteolysis of the respective proteins, and the automated generation and interpretation of collision-induced dissociation spectra.
Explore the source record for details and available documents.
We describe the coupling of a microfabricated fluidic device to an electrospray ionization (ESI) quadrupole time-of-flight mass spectrometer (QqTOFMS) for the identification of protein samples. The microfabricated devices consisted of three reservoirs connected via channels to a main capillary, which in turn was linked via a microspray interface to the QqTOFMS. Here we present preliminary results obtained using this system. Standardized solutions of myoglobin tryptic digest were analyzed indicating a limit of detection at the low to sub fmol/microL. The combination of the microfabricated device for rapid sample delivery and the rapid acquisition capability, enhanced resolution and mass accuracy of the QqTOF offers unique possibilities for the rapid identification of proteins by database searching. This platform can generate MS data suitable for protein database searching by the peptide-mass fingerprinting approach and MS/MS data suitable for protein database searching. Here the results of the two database-searching approaches are compared and the possibilities of combining the two approaches for rapid identification of protein are discussed. Also, we present a comparison of the results obtained using the three-position microfabricated device coupled to the ESI-QqTOFMS and to an ESI-ion trap MS. Finally the combination of C-terminal 18O labeling of peptides and the microfabricated system for automated combined peptide-mass fingerprinting and sequence-tag database searching is discussed.
Analytical biochemistry, in particular the analysis of regulatory proteins that control biological systems and pathways, is dependent on methods of ever-increasing sensitivity. Capillary electrophoresis (CE) has long been recognized as an ultrasensitive analytical technique. In spite of the high sensitivity, CE has not penetrated protein discovery research as a standard analytical method. In this review article we summarize recent technical developments which have significantly enhanced CE as a tool for the analysis of trace amounts of proteins. Specifically, we review recent advances in the development and application of capillary electrophoresis-mass spectrometry (CE-MS) and on-line analyte concentration techniques, and introduce the emerging field of microfluidics as a front end to mass spectrometry (MS).
Analytical and preparative electrophoresis separation techniques have been essential tools in protein biochemistry and the biological sciences in general. The combination of high resolution electrophoresis techniques with high performance analytical procedures has dramatically enhanced analytical protein biochemistry. In this report we describe the combination of electrophoretic separation techniques with electrospray ionization (ESI) tandem mass spectrometry (MS/MS). A series of different techniques, consisting of automated high performance liquid chromatography (HPLC)-MS/MS, capillary-HPLC-MS/MS, and solid phase extraction (SPE)-capillary zone electrophoresis (CZE)-MS/MS, are described in the context of the identification of high pmol to the low fmol amounts of proteins. Application of these powerful new tools for the analysis of proteins on a large proteome-wide scale is presented. Furthermore, the combination of orthogonal separation techniques, such as immobilized metal affinity chromatography (IMAC) with SPE-CZE-MS/MS, and IMAC followed by HPLC, and by SPE-CZE-MS/MS, are presented for the detailed investigation of post-translational modifications of specific proteins.
In this review we examine the current state of proteome analysis. There are three main issues discussed: why it is necessary to study proteomes; how proteomes can be analyzed with current technology; and how proteome analysis can be used to enhance biological research. We conclude that proteome analysis is an essential tool in the understanding of regulated biological systems. Current technology, while still mostly limited to the more abundant proteins, enables the use of proteome analysis both to establish databases of proteins present, and to perform biological assays involving measurement of multiple variables. We believe that the utility of proteome analysis in future biological research will continue to be enhanced by further improvements in analytical technology.
We have previously described the use of a solid phase extraction (SPE) - capillary zone electrophoresis (CZE) - tandem mass spectrometry (MS/MS) system for protein analysis at the low femtomole to subfemtomole level. Here we describe the systematic optimization of a number of parameters which facilitate the use of the SPE-CZE-MS/MS system and further enhance its performance. Specifically, we describe a robust SPE cartridge design which can be assembled without the use of glue, the evaluation of procedures to chemically modify the inner wall of the fused-silica capillaries used in the system to improve separation and reproducibility, and the comparison of different reverse-phase (RP) resins used for the SPE cartridge. We also explored the effects of transient isotachophoresis with respect to system performance and compatibility with different fused-silica surface coatings, the RP resins used, and MS/MS. The enhanced performance of the optimized system is demonstrated by the analysis of calibrated tryptic digests of bovine serum albumin (BSA).
Explore the source record for details and available documents.
Nanoelectrospray mass spectrometry, the infusion at low flow rates of unseparated peptide mixtures representing protein proteolytic digests into an electrospray ionization mass spectrometer (MS), has been shown to be a suitable method for the analysis of small amounts of proteins. However, the current technique is time consuming, tedious, and difficult to automate. We used microfabrication technologies to construct a device for the sequential infusion of different peptide samples into an electrospray ionization MS without the need for sample manipulation. In this device, etched sample and buffer reservoirs are connected via etched channels to microelectrospray ion source. Peptide samples, typically unseparated tryptic digests of proteins, are applied to different reservoirs. A flow of liquid originating from a specific reservoir is generated and selectively directed toward the microsprayer and the MS by electroosmotic pumping. The analyte proteins are identified by searching sequence databases with the information contained in the collision-induced spectra of selected peptides. With this system, we have achieved a limit of detection in the low femtomoles per microliter range for peptide standards. We also show that samples deposited in different reservoirs can be sequentially mobilized without cross-contamination and that proteins can be conclusively identified at the low femtomoles per microliter level. The successful coupling online of microfabricated devices to an electrospray ionization MS represents an essential step toward the construction of automated, high-throughput, and high-sensitivity analytical systems.
Two procedures for the derivatization of the inner wall of fused-silica capillaries for the analysis of peptides and proteins by capillary electrophoresis (CE) at neutral pH are presented. In the first procedure, polyethyleneimine (PEI) is covalently attached to the capillary wall. In the second procedure, PEI is additionally cross-linked. We present analysis of standard peptides and proteins by CE using the coated capillaries. These coatings will have application for the separation of protein complexes at neutral pH, prior to analysis by electrospray mass spectrometry.
Capillary electrophoresis-tandem mass spectrometry has been used successfully for the analysis of complex peptide mixtures. The method is limited by a relatively high concentration limit of detection and by matrix effects. Here we describe on-line coupling of a solid-phase microextraction device to a capillary electrophoresis-tandem mass spectrometry system. The performance of the integrated instrument was evaluated for the identification of proteins by their amino acid sequence. We report that the concentration limit of detection was improved at least 1000 fold to the low attomole/microliter range and that matrix effects were minimized by extensive sample clean-up during solid-phase extraction. We demonstrate that the implementation of a solid-phase extraction device significantly enhances capillary electrophoresis-tandem mass spectrometry as a method for the identification of low abundance proteins isolated from high-resolution two-dimensional polyacrylamide gels.
While injection volumes in capillary electrophoresis are typically in the nanoliter range, it is difficult to physically prepare and manipulate samples much smaller than a microliter. As a result, only a small fraction of the analyte contained with the sample volume is transferred to the capillary. This problem is particularly acute in DNA sequencing applications, where on-column stacking is difficult and where the sequencing sample is relatively expensive to prepare. We report a method that transfers 75% of the DNA contained within a 3 microliters sample onto a capillary for DNA sequencing. This method relies on the use of very low ionic strength formamide to resuspend the DNA after an ethanol precipitation. The use of low ionic strength formamide achieves two tasks. First, it produces a very high resistance sample, which increases the voltage drop across the sample and decreases the field across the capillary. This electric field manipulation ensures that DNA fragments do not migrate down the capillary during the loading process, allowing long injection periods without excessive band-broadening. Second, the low ionic strength of the formamide increases the transference number of the DNA; more of the current passing through the injection tip of the capillary is carried by DNA fragments. In the limit of complete elimination of impurity ions from the loading solvent, current passing through the sample is carried only by DNA fragments and loading becomes a coulometric process.