PubMed Health⌕ Search

Biomedical subjects

D Findley

Publications and source records attributed to D Findley.

4 recordsLinked to original sources

The Dimensional Yale-Brown Obsessive-Compulsive Scale (DY-BOCS): an instrument for assessing obsessive-compulsive symptom dimensions.

Obsessive-compulsive disorder (OCD) encompasses a broad range of symptoms representing multiple domains. This complex phenotype can be summarized using a few consistent and temporally stable symptom dimensions. The objective of this study was to assess the psychometric properties of the Dimensional Yale-Brown Obsessive-Compulsive Scale (DY-BOCS). This scale measures the presence and severity of obsessive-compulsive (OC) symptoms within six distinct dimensions that combine thematically related obsessions and compulsions. The DY-BOCS includes portions to be used as a self-report instrument and portions to be used by expert raters, including global ratings of OC symptom severity and overall impairment. We assessed 137 patients with a Diagnostic and Statistical Manual-IV diagnosis of OCD, aged 6-69 years, from sites in the USA, Canada and Brazil. Estimates of the reliability and validity of both the expert and self-report versions of the DY-BOCS were calculated and stratified according to age (pediatric vs. adult subjects). The internal consistency of each of the six symptom dimensions and the global severity score were excellent. The inter-rater agreement was also excellent for all component scores. Self-report and expert ratings were highly intercorrelated. The global DY-BOCS score was highly correlated with the total Yale-Brown Obsessive-Compulsive Scale score (Pearson r = 0.82, P<0.0001). Severity scores for individual symptom dimensions were largely independent of one another, only modestly correlated with the global ratings, and were also differentially related to ratings of depression, anxiety and tic severity. No major differences were observed when the results were stratified by age. These results indicate that the DY-BOCS is a reliable and valid instrument for assessing multiple aspects of OCD symptom severity in natural history, neuroimaging, treatment response and genetic studies when administered by expert clinicians or their highly trained staff.

Adolescent↗

Physical characteristics of a miniature multileaf collimator.

A preliminary study of the physical characteristics of a miniature multileaf collimator (mMLC) used with 4 MV x rays is reported. The mMLC attached to the accessory mount of a class C or D Varian linear accelerator (Varian Oncology Systems, Palo Alto, CA) with a source to aperture distance of 65 cm. The field penumbra using the small leaves was found to be consistent with the anticipated field penumbra using photon jaws at the same source to aperture distance as the mMLC. The percentage depth dose values of square fields were found to be consistent with the fields collimated with the upper and lower jaws. Output factors for the very small fields were found to vary rapidly. Circular fields could be produced with depth dose characteristics similar to those produced using conical tertiary collimators, commonly used for radiosurgery, but with a broader penumbra.

Dose-Response Relationship, Radiation↗

Clinical implementation of a Monte Carlo treatment planning system.

The purpose of this study was to implement the Monte Carlo method for clinical radiotherapy dose calculations. We used the EGS4/BEAM code to obtain the phase-space data for 6-20 MeV electron beams and 4, 6, and 15 MV photon beams for Varian Clinac 1800, 2100C, and 2300CD accelerators. A multiple-source model was used to reconstruct the phase-space data for both electron and photon beams, which retained the accuracy of the Monte Carlo beam data. The multiple-source model reduced the phase-space data storage requirement by a factor of 1000 and the accelerator simulation time by a factor of 10 or more. Agreement within 2% was achieved between the Monte Carlo calculations and measurements of the dose distributions in homogeneous and heterogeneous phantoms for various field sizes, source-surface distances, and beam modulations. The Monte Carlo calculated electron output factors were within 2% of the measured values for various treatment fields while the heterogeneity correction factors for various lung and bone phantoms were within 1% for photon beams and within 2% for electron beams. The EGS4/DOSXYZ Monte Carlo code was used for phantom and patient dose calculations. The results were compared to the dose distributions produced by a conventional treatment planning system and an intensity-modulated radiotherapy inverse-planning system. Significant differences (>5% in dose and >5 mm shift in isodose lines) were found between Monte Carlo calculations and the analytical calculations implemented in the commercial systems. Treatment sites showing the largest dose differences were for head and neck, lung, and breast cases.

Algorithms↗

An xo cat.

Explore the source record for details and available documents.

Animals↗