PubMed Health⌕ Search

Biomedical subjects

D G Barth

Publications and source records attributed to D G Barth.

2 recordsLinked to original sources

Altered kinetic strategy for the control of swing limb elevation over obstacles in unilateral below-knee amputee gait.

Our goal was to document the kinetic strategies for obstacle avoidance in below-knee amputees. Kinematic data were collected as unilateral below-knee traumatic amputees stepped over obstacles of various heights in the walking path. Inverse dynamics were employed to calculate power profiles and work during the limb-elevation and limb-lowering phases. Limb elevation was achieved by employing a different strategy of intra-limb interaction for elevation of the prosthetic limb than for the sound limb, which was similar to that seen in healthy adult non-amputees. As obstacle height increased, prosthetic side knee flexion was increased by modulating the work done at the hip, and not the knee, as seen on the sound side. Although the strength of the muscles about the residual knee was preserved, the range of motion of that knee had previously been found to be somewhat limited. Perhaps more importantly, potential instability of the interface between the stump and the prosthetic socket, and associated discomfort at the stump could explain the altered limb-elevation strategy. Interestingly, the limb-lowering strategy seen in the sound limb and in non-amputees already features modulation of rotational and translational work at the hip, so an alternate strategy was not required. Thus, following a major insult to the sensory and neuromuscular system, the CNS is able to update the internal model of the locomotor apparatus as the individual uses the new limb in a variety of movements, and modify control strategies as appropriate.

Adaptation, Physiological↗

Static structural testing of trans-tibial composite sockets.

The purpose of this investigation was to quantify the structural strength of various trans-tibial composite sockets. To conduct the study, loading parameters and methods were developed that emulate the International Standards Organisation (ISO) standards for structural testing of lower limb prostheses since specific guidelines for the testing of the trans-tibial socket portion of a prosthesis have not yet been established. The experimental set-up simulated the instant of maximum loading during the late stance phase of gait. Ten trans-tibial sockets were evaluated. Five different reinforcement materials and two resin types were used to construct the sockets. A standard four hole distal attachment plate was used to connect the socket and pylon. Each sample was loaded to failure in a servo-hydraulic materials test machine at 100 N/s. None of the composites in the study met the ISO 10328 standards for level A100, loading condition II (4025 N), as required for other prosthetic componentry. All failures occurred at the site of the pyramid attachment plate. Ultimate strength and failure type were material dependent. Load point deflection was significantly different for the resin variable (p<0.05). Statistical differences according to reinforcement material were noted in composite weight and strength-to-weight ratio (p<0.05). The fibre volume fraction was also estimated and recorded. Reinforcement material type was the primary determinant of performance for the tested samples. Carbon reinforcements performed better than fibreglass reinforcements of similar weave type. The greatest ultimate strength and strength-to-weight ratio was observed with the unidirectional carbon reinforcement.

Acrylic Resins↗