PubMed Health⌕ Search

Biomedical subjects

D G Becker

Publications and source records attributed to D G Becker.

At least 37 records · Page 2Linked to original sources

A new compound-curved needle for microvascular surgery.

A new compound-curved needle has been designed and developed for microvascular surgery from a unique stainless steel alloy, American Society for Testing Materials 45500. This needle has two distinct radii of curvature and a short tapered point, followed by a curved distal section. Despite its geometry, it exhibits similar resistance to bending and breakage as a curved needle with a single radius of curvature manufactured from the same alloy. The design of this new needle enables plastic surgeons to pass it through vessel walls with greater accuracy to a controlled depth and length of bite than a curved needle with a single radius of curvature.

Humans↗

Biochemical performance of tapercut cardiovascular needles.

Standardized reproducible tests have been developed to determine the biomechanical performance of cardiovascular needles. The parameters used to assess performance were: 1) sharpness, 2) resistance to bending, and 3) ductility. Four comparable groups of tapercut and taper point cardiovascular needles were selected from different manufacturers for these biochemical studies. The results of this testing demonstrated that needle geometry, needle composition, and the manufacturer were important determinants of needle performance. When comparable needles were evaluated, the biochemical performance of cardiovascular needles manufactured by Ethicon, Inc. (Somerville, NJ) were superior to needles produced by other manufacturers. The superior performance characteristics of the cardiovascular needles produced by Ethicon, Inc. were related to their unique stainless steel alloy, American Society for Testing Materials 45500, which has greater yield and tensile strengths than the alloy used by the other manufacturers. This stainless steel alloy was ideal for the production of tapercut needles, which combined some of the features of a reverse cutting edge needle and taper point needle. Its very short cutting edges allowed it to penetrate the membrane at considerably lower penetration forces than were encountered with comparable taper point needles. In addition, the investigation indicated that the trocar point cardiovascular needles produced a large triangular defect whose diameter was much larger than that of the needle body. For this reason, the use of the trochar point needle is not recommended in cardiovascular surgery.

Biomechanical Phenomena↗

Scientific basis for selecting staple and tape skin closures.

Use of tape and skin staples has many important clinical applications for surgical wounds. During the past two decades, our research program has identified the optimal performance parameters of these wound closure devices. On the basis of their unique performance characteristics, specific staplers and tapes are recommended for wound closure. The scientific basis for selecting staples and tapes for wound closure is based on their influences on the biology of wound repair and infection.

Bandages↗

Scientific basis for selecting surgical needles and needle holders for wound closure.

Standardized reproducible tests have been devised to determine surgical needle sharpness, resistance to bending, and ductility. Three comparable groups of reverse cutting edge needles were selected from different manufacturers for measurement of these needle performance parameters. This testing demonstrated that needle diameter, manufacturing process, needle material composition, cross-sectional design, and the manufacturer were all important determinants of surgical needle performance. In addition, the biomechanics of curved surgical needle bending has been related to the clamping moment of surgical needle holders. This relationship identifies the surgical needle holder that can be used with surgical needles without deformation. The results of these studies provide a scientific basis for the selection of surgical needles and needle holders for use in surgery.

Equipment Design↗

Metallurgically bonded needle holder jaws. A technique to enhance needle holding security without sutural damage.

A new needle holder jaw face has been specifically designed and developed to increase needle holding security without sutural damage. Tungsten carbide particles have been metallurgically bonded into the stainless steel jaw to create a fine granular surface. This bonded jaw enhances needle holding security by limiting either twisting or rotation of the clamped needle. In addition, compression of the monofilament synthetic sutures by the bonded jaws does not reduce suture breaking strength.

Equipment Design↗

A 3-year multi-institutional experience with the liposhaver.

OBJECTIVE: To report a 3-year multi-institutional clinical experience with the liposhaver in facial plastic surgery. DESIGN: Nonrandomized, nonblinded, multi-institutional evaluation of the liposhaver in a clinical setting. INTERVENTIONS: Seventy-two patients who presented for facial plastic surgical procedures underwent surgery with the liposhaver. Seventy-six liposhaving procedures and 74 concomitant procedures were performed. Standardized preoperative and postoperative photographs were obtained. OUTCOME MEASURE: Subjective evaluation by the surgeons who performed the procedures. RESULTS: The liposhaver was used successfully in all cases. The fat was cleanly shaved and the contour results were even, without dimpling or significant asymmetry. Operative time was comparable to that of conventional liposuction. There were no cases of facial nerve injury and no evidence of increased bleeding intraoperatively. Two male patients had small postoperative hematomas in the immediate postoperative period that were successfully treated with conservative measures. An additional patient developed a small hematoma on postoperative day 5 that was effectively treated with needle aspiration and a pressure dressing. CONCLUSION: This 3-year multi-institutional report suggests that the liposhaver continues to offer a precise alternative to conventional liposuction.

Equipment Design↗

Treating the caudal septal deflection.

Caudal septal deflection can be a challenging nasal deformity. Although there are a number of maneuvers available to manage this functional and aesthetic abnormality, each approach is effective in only a limited number of cases. For over 25 years, the senior author (N.J.P.) has employed a "modified swinging door" technique for treatment of the deviated caudal septum. Using this technique, the septal cartilage along the maxillary crest is dissected free but is not excised. Instead, the caudal septum is flipped over the nasal spine, which acts as a "doorstop" and secures the caudal septum in a straighter position. This maneuver may be useful in the armamentarium of the surgeon managing this potentially difficult technical challenge.

Humans↗

The radix graft in cosmetic rhinoplasty.

Experience with rhinoplasty over time has shown that a detailed anatomic analysis of the nose is an essential first step in achieving a successful outcome. Failure to recognize a particular anatomic point preoperatively will often lead to a less than ideal long-term result. Deficiency in the radix is a commonly overlooked abnormality that may be found both in patients undergoing primary rhinoplasty and patients undergoing revision rhinoplasty after an overzealous bony hump removal. Whereas surgeons previously reduced the nasal dorsum down to the level of the radix on a routine basis, recent emphasis on a strong natural profile has focused attention on anatomic deficiency in the radix region. We describe a simple technique for treatment of the deep nasofrontal angle and present patient examples. Autologous cartilage grafts may be fashioned into a "radix graft" and reliably used to augment the region either with a precise pocket approach or without when a precise pocket is not possible, achieving a natural aesthetic result.

Adult↗

Emergency physician's needle holder.

A new needle holder is described that has jaws metallurgically bonded with tungsten carbide particles that enhance needle holding security without causing sutural damage during instrument ties. Scissors have also been incorporated into the needle holder to cut sutures. One ringlet on a handle has been offset to facilitate retrieval of the needle holder from a flat surface.

Emergency Medicine↗

A new compound curved needle for intradermal suture closure.

A new compound curved needle has been designed and developed for intradermal suture closure from a unique stainless steel alloy, American Society of Testing Materials (ASTM) 45500. This needle has a short, straight, sharpened point with a reverse cutting edge, followed by a curved distal section. Despite its geometry, it exhibited a similar resistance to bending and breakage as did a curved needle with a single radius of curvature manufactured from the same alloy. The design of this new needle enabled the physician to pass it through the dermis with a greater accuracy to a controlled depth and length of bite than curved cutting edge needle with a single radius of curvature.

Clinical Trials as Topic↗

A beveled, conventional cutting edge surgical needle: a new innovation in wound closure.

A new beveled, conventional cutting edge needle has been developed with superior performance characteristics over those of other conventional cutting edge needles. It is composed of a unique stainless steel, ASTM 45500, that has been heat-treated after the curving process to enhance its resistance to bending. The angle of presentation of its cutting edges has been decreased to enhance needle sharpness. On the basis of the results of experimental and clinical investigations, this new needle is recommended for closure of lacerations.

Clinical Trials as Topic↗

Blepharospasm-oromandibular dystonia associated with a left cerebellopontine angle meningioma.

Blepharospasm-oromandibular dystonia is characterized by the presence of spasms of the orbicularis oculi (blepharospasm) and of the lower facial or oromandibular muscles. A patient with this syndrome is presented in which a left cerebellopontine angle meningioma appeared to act as a triggering mechanism for the development of this disorder. On the basis of this report, we recommend that physicians search for this tumor in patients with this disorder.

Cerebellar Neoplasms↗

Influence of knot configuration and tying technique on the mechanical performance of sutures.

The purpose of this investigation was to determine the influence of knot configuration and tying technique on the mechanical performance of surgical sutures. Multifilament and monofilament nylon sutures were selected for this evaluation because they are commonly used in wound closure. The mechanical performance of these sutures was judged by the following parameters: knot breakage force, configuration of secure knots, and knot run down force. During each test, tension was applied at either rapid or slow rates, which correlates with the physician's speed of tying knots. On the basis of these mechanical performance tests, four throw square (1 = 1 = 1 =1) knots and five throw square (1 = 1 = 1 = 1 = 1) knots are recommended for monofilament nylon and multifilament nylon sutures, respectively, in which the speed of application of forces to the knots is relatively slow. Because these tests can easily be replicated in any laboratory, manufacturers now have a scientific basis for recommending specific tying techniques for their surgical sutures.

Physical Phenomena↗

Injury due to uncontrolled acceleration of an electric wheelchair.

Approximately 750,000 disabled individuals use electrical platform mobility aids (wheelchairs) for adaptive transportation. Because there are no mandatory standards for platform mobility aids and wheelchairs, these adaptive transportation aids are prone to potential design and maintenance problems. An injury caused by uncontrolled acceleration of a platform mobility aid is reported. Examination of the platform mobility aid identified a defect in its speed control regulator that has been subsequently corrected by the manufacturer.

Acceleration↗

Damage to tissue defenses by EMLA cream.

EMLA is a new topical agent that safely anesthetizes intact skin. The purpose of this study was to determine if this cream could be safely used for anesthetizing wounds. This investigation evaluated the potential toxicity of EMLA cream in wounds by measuring its effect on host defenses and on the biology of wound repair. In contaminated wounds, EMLA cream elicited an exaggerated inflammatory response that damaged host defenses, inviting the development of infection. As a result of these investigations, we do not recommend the use of EMLA cream in wounds.

Anesthetics, Local↗

Evaluation of buoyant hydrofitness devices for leg musculoskeletal conditioning.

Air splints have been used for immobilization of fractures, skin graft stabilization and preprosthetic rehabilitation of the amputated lower limb. The purpose of this clinical study was to assess its use as a hydrofitness device to facilitate walking reeducation, to produce muscle strengthening and to increase joint extensibility in patients with weak legs. The performance of the air splint as a hydrofitness device was compared to that of the new foam hydrofitness device. The parameters used to assess the performance of these devices included durability, application and removal times, joint extensibility and the magnitude of the fluid drag forces. On the basis of this evaluation, the performance of the foam hydrofitness device was judged to be superior to that of the air splint for leg musculoskeletal conditioning.

Humans↗

Is there a need for state health department sanitary codes for public hydrotherapy and swimming pools?

The Board of Health of the Commonwealth of Virginia has an outdated sanitary code for its public hydrotherapy and swimming pools. The code is restricted to pools in hotels and other lodging places. The absence of modern regulations for public hydrotherapy and swimming pools has permitted serious deficiencies in pool maintenance, which are highlighted in this report. The most notable of these deficiencies was the presence of high levels of bacterial contamination that could predispose to infect in the water of one public hot tub. The results of this study indicate that the Virginia Board of Health sanitary code for pool water must be revised immediately and should include all public hydrotherapy and swimming pools. Other states and communities may want to assess their codes for swimming pools and hydrotherapy tubs to avoid deficiencies that could be detrimental to public health.

Bacteria↗