Resumption of motor vehicle operation in vasovagal fainters.

This study surveyed current practice patterns with respect to the manner by which cardiac arrhythmia specialists advise patients with vasovagal syncope regarding resumption of motor vehicle operation. Among 66 physician-respondents from 9 countries, 98% indicated that they rely on tilt-table testing to establish a diagnosis, and, if an effective treatment is found based on serial tilt-table testing, they recommend a 6- to 7-week symptom-free waiting period before advising return to driving.

Attitude of Health Personnel

Prehospital discharge defibrillation testing in ICD recipients: a prospective study based on cost analysis.

Prehospital discharge defibrillation testing is often performed to verify the function of newly implanted cardioverter defibrillators (ICDs). To determine whether elimination of predischarge testing could reduce costs without placing patients at additional risk, 31 patients were randomized in this prospective clinical evaluation to either receive or not receive a predischarge ICD defibrillation test. Expenses associated with postimplant care was the primary endpoint. All patients underwent induction of ventricular fibrillation after 6 months to evaluate ICD function. The groups were well matched in terms of patient characteristics, initial lead implant parameters, and defibrillation thresholds. Elimination of prehospital discharge testing resulted in a savings of $1,800/patient after 6 months, with no difference between groups in terms of ICD complication rates or unanticipated hospital admissions. Further studies are needed to better define the most appropriate time to assess defibrillation thresholds in the first year after implantation.

Aged

"Sagging heart syndrome": a cause of acute lead dislodgment in two patients.

Acute passive fixation atrial lead dislodgment occurred due to an unexpected and marked postural descent of the heart after permanent pacemaker implantation in two patients. Sagging of the heart in these two individuals may have been related to a history of morbid obesity followed by weight loss of over 100 pounds. Lead replacement with active fixation leads was required in both cases. The term "sagging heart syndrome" is proposed to describe this clinical entity. In certain adult populations, such as in patients with a history of significant weight loss, the "sagging heart syndrome" may represent a previously unrecognized cause of acute lead dislodgment.

Electrodes, Implanted

Physiologic cardiac pacing in patients with contemporary implantable cardioverter-defibrillators.

Contemporary implantable cardioverter-defibrillators (ICD) incorporate single-chamber ventricular pacing capability. However, because poor ventricular function and/or congestive heart failure is common in the ICD population, the provision of more "physiologic" pacing modes has been receiving increased attention. To evaluate the potential impact of ICDs with physiologic pacing features, we assessed the frequency with which atrial-based pacing modes with or without rate responsiveness are currently used in ICD recipients. Further, we characterized those clinical variables at initial ICD implant that tended to be associated with subsequent need for physiologic pacing. Clinical findings were reviewed in 250 consecutive patients who received ICDs with VVI pacing capability at the University of Minnesota Cardiac Arrhythmia Center between January 1991 and February 1997. Adjunctive physiologic pacing was undertaken in 35 patients (14%): 13 before or at the same time as their ICD, and 22 within a mean of 2.5 years after initial ICD surgery. A history of atrial tachyarrhythmia before ICD implantation (p <0.0001) and treatment with antiarrhythmic drugs at the time of ICD surgery (p <0.05) were predictors of subsequent need for physiologic pacing. The type of presenting ventricular tachyarrhythmia and electrophysiologic parameters (such as the HV interval and the shortest atrial pacing cycle length associated with 1:1 anterograde atrioventricular conduction) were not associated with a subsequent decision to implant a physiologic pacing system. Thus, we conclude that despite the need to implant a second device, physiologic pacing is currently used in an important subset of ICD recipients. Further, certain clinical features at time of ICD implant appear to characterize these patients and may prove helpful in patient selection for the next generation "dual-chamber" ICD.

Adolescent

Digital cellular telephone interaction with implantable cardioverter-defibrillators.

OBJECTIVES: This study sought to determine, in vivo, whether electromagnetic interference (EMI), generated by North American Digital Communications (NADC)/Time Division Multiple Access-50-Hz (TDMA-50) mobile cellular digital telephone model AT&T 6650, disturbs normal implantable cardioverter-defibrillator (ICD) operation and to verify these observations in vitro by testing a selection of telephones representing worldwide systems. METHODS: The effects of cellular phone interference on the operation of various models of market-released ICDs from a single manufacturer, Medtronic, Inc., were tested. The in vivo clinical test was undertaken in 41 patients using the AT&T 6650 digital telephone with the NADC/TDMA-50 technology. The in vitro component of the study was examined twofold: 1) antenna generated far field; and 2) analog/digital cellular telephone near field. RESULTS: None of the ICDs tested in 41 patients were affected by oversensing of the EMI field of the cellular telephones during the in vivo study. Therefore, the binomial upper 95% confidence limit for the failure rate of 0% is 7%. The in vitro antenna-generated field testing showed that telephone modulation frequencies used in the international Global System Mobile and TDMA-50 cellular telephone technologies did not result in ICD sensing interference at the predicted electric field intensity. The in vitro near field tests were performed using both analog and digital cellular telephones in service, or in the test mode, and indicated no interaction with normal operation. However, the static magnetic field generated by the cellular telephone placed over the ICD at a distance < or = 0.5 cm will activate the internal reed switch, resulting in temporary suspension of ventricular tachycardia and fibrillation detection. CONCLUSIONS: We conclude that TDMA-50 cellular telephones did not interfere with these types of ICDs. However, we recommend that the patient not carry or place the digital cellular telephone within 15 cm (6 in.) of the ICD.

Defibrillators, Implantable

Review article: heart rate and blood pressure control in vasovagal syncope.

Vasovagal syncope is characterized by transient failure of usually reliable physiologic mechanisms responsible for maintaining both systemic arterial pressure and cerebral blood flow. Two circulatory phenomena are almost universally present: systemic arterial vasodilation and bradycardia. A third phenomenon, cerebrovascular constriction, has also been described but its contribution to the faint is less well established. The neural reflex pathways responsible for triggering the circulatory changes in the vasovagal faint are incompletely understood, but have recently been the subject of renewed interest. In part, this interest probably stems from the frequency with which vasovagal symptoms are now recognized to be the cause of fainting spells. Additionally, however, there is an increasingly recognized need to develop treatment strategies for those affected patients in whom recurrent vasovagal symptoms are particularly troublesome. It is the goal of this discussion to focus on those aspects of circulatory control, and in particular on potential interactions among certain neural and humoral systems, which may contribute to the inappropriate physiologic responses associated with the vasovagal faint.

Afferent Pathways

Submuscular versus subcutaneous pectoral implantation of cardioverter-defibrillators: effect on high voltage pathway impedance and defibrillation efficacy.

Implantable cardioverter-defibrillator (ICD) pulse generators are now routinely positioned in a pectoral location, either submuscularly (under the pectoralis muscles) or subcutaneously (over the pectoralis muscles). Furthermore, in current ICDs, the generator shield usually participates in the defibrillation energy pathway ("hot can"). Consequently, the precise generator location could affect defibrillation system efficacy. To assess this issue, we compared high voltage pathway impedance and defibrillation threshold (DFT) in 20 patients undergoing submuscular and 46 patients undergoing subcutaneous pectoral implantation of an Angeion Sentinel ICD and an AngeFlex dual-coil defibrillation lead. Measurements were performed at time of ICD implant, pre-hospital discharge, and 1, 3 and/or 6 months later. Following induction of ventricular fibrillation, 569 biphasic waveform shocks were delivered between the generator shield and either the distal defibrillation coil (RV/can configuration) or both proximal and distal coils (RV/SVC/can configuration). Impedance differences between submuscular and subcutaneous implants were approximately 3-4 Ohms (p value of 0.132 to < 0.001 depending on time of follow-up and lead configuration). A significant increase in impedance over time was noted independent of implant location and lead configuration. The DFT at implant or pre-discharge was assessed in 27 individuals, and was 9.9 +/- 3.8 J in 8 patients in the submuscular group, and 7.4 +/- 3.3 J in 19 patients in the subcutaneous group (p = 0.057). In conclusion, anatomic location of a "hot can" ICD generator (submuscular versus subcutaneous) influences impedance to defibrillation current, but the impact is of small magnitude and does not appear to result in clinically important differences in DFT.

Aged

NASPE expert consensus document: use of i.v. (conscious) sedation/analgesia by nonanesthesia personnel in patients undergoing arrhythmia specific diagnostic, therapeutic, and surgical procedures.

Use of IV (Conscious) Sedation/Analgesia by Nonanesthesia Personnel in Patients Undergoing Arrhythmia Specific Diagnostic, Therapeutic, and Surgical Procedures. This article is intended to inform practitioners, payers, and other interested parties of the opinion of the North American Society of Pacing and Electrophysiology (NASPE) concerning evolving areas of clinical practice or technologies or both, that are widely available or are new to the practice community. Expert consensus documents are so designated because the evidence base and experience with the technology or clinical practice are not yet sufficiently well developed, or rigorously controlled trials are not yet available that would support a more definitive statement. This article has been endorsed by the American College of Cardiology, October 1997.

Anesthesiology

Comparison of right atrial and peripheral procainamide infusion levels in patients with spontaneous or induced atrial fibrillation.

As part of a new effort to develop an implantable drug infusion/pacing system to treat atrial fibrillation, this study examined the effects of rapid intracardiac procainamide infusion in humans with pacing-induced atrial fibrillation. Twenty patients with atrial fibrillation for > 5 minutes during an EP study received 500 mg of procainamide either via a peripheral venous infusion (n = 5) or directly in the right atrium (n = 15). Peak coronary sinus and femoral vein procainamide blood levels (mean +/- SEM) during 10, 5, and 3.3 minute central infusions were 17.0 +/- 4.1, 25.1 +/- 4.5, 45.6 +/- 5.1 and 11.3 +/- 3.2, 17.1 +/- 6.4, 18.7 +/- 5.0, respectively. In contrast, peak coronary sinus and femoral procainamide levels following the 5 minute intravenous infusion were 17.7 +/- 5.1 and 9.3 +/- 2.1. Changes in QT, QTc, QRS, and RI intervals were similar at each infusion rate. Systolic blood pressures (BP) decreased more with higher procainamide infusion rates but similar when comparing intravenous versus central drug administration at the same rate. The mean +/- SEM decreases in blood pressure with the 10, 5, and 3.3 min procainamide infusions were 12f5, 20f11, and 39f14, respectively. Conversion to sinus rhythm was not a primary endpoint given the often transient nature of acute atrial fibrillation in this setting. We conclude that significantly higher femoral vein and coronary sinus procainamide levels can be achieved by central rather than peripheral drug infusion. These data support that concept that rapid central infusion of anti-arrhythmic therapy can result in high intracardiac levels of antifibrillatory agents for the treatment of paroxysmal atrial fibrillation.

Adult

A method for permanent transvenous left ventricular pacing.

LV-based pacing has recently been reported to be of benefit in patients with severe cardiac failure and left bundle branch block. LV permanent pacing has been reported using epicardial leads but the surgical mortality is excessive. A transvenous approach is now favored. In this regard, cannulation of the coronary sinus and of one of its tributaries using only the permanent electrode is feasible but technically challenging. We describe a "long guiding sheath" method using catheterization, and a long radiopaque and peelable sheath. Once the coronary sinus is cannulated with the electrophysiological catheter, the long sheath is advanced to the mid-part of the coronary sinus. The permanent pacing electrode is then placed through the sheath and into a tributary of the coronary sinus. This method has been attempted in 10 patients and was successful in 8, with an average lead insertion time of 21 +/- 5.5 minutes and an average fluoroscopic time of 11 +/- 5.5 minutes. In conclusion, although transvenous left ventricular pacing remains a challenge, the "long guiding sheath" approach appears to facilitate this procedure with both a high success rate and an acceptable procedure time.

Bundle-Branch Block

Recurrent supine syncope: an unusual manifestation of the neurally mediated faint.

INTRODUCTION: Syncope occasionally may occur in the supine patient due to severe brady- or tachyarrhythmia. However, recurrent syncope upon assumption of the supine position as a result of a neurally mediated reflex mechanism has not been reported previously. METHODS AND RESULTS: Two young patients, both of whom had significant systemic illnesses, experienced recurrent episodes of presyncope and/or syncope shortly after assuming the supine position. During ambulatory ECG monitoring, symptoms were provoked only by lying down and were associated with transient bradycardia. Head-up tilt table testing was undertaken as part of the syncope evaluation and was nondiagnostic in both cases. However, both patients exhibited a transient cardioinhibitory response with reproduction of typical symptoms upon return of the table to the supine position ("reverse tilt"). During follow-up (8 and 14 months), both patients improved with pharmacologic treatment (disopyramide in one case and midodrine in the other). CONCLUSION: Presyncope or syncope upon lying down can be an unusual manifestation of the neurally mediated faint.

Adult

Evaluation of different ventricular pacing sites in patients with severe heart failure: results of an acute hemodynamic study.

BACKGROUND: Multisite ventricular pacing has recently been proposed as an additional treatment for patients with severe congestive heart failure. To further assess the potential value of this technique, we compared the acute hemodynamic changes associated with pacing the right ventricular apex (RVA) or outflow tract (RVOT) alone, the left ventricle (LV) alone, or biventricular (BIV) pacing of the RVA and LV together. METHODS AND RESULTS: Acute hemodynamic findings were measured in 27 patients with severe heart failure despite optimal therapy and either first-degree AV block and/or an intraventricular conduction defect. In the 23 patients with a high pulmonary capillary wedge pressure (PCWP) (>15 mm Hg), data were collected after transvenous pacing at different ventricular sites in either the VDD mode (AV delay=100 ms) or the VVI mode in patients with atrial fibrillation (n=6). The mean baseline cardiac index was 1.82 L x min(-1) x m(-2). Mean+/-SD baseline systolic blood pressure (SBP) (118.5+/-15.2 mm Hg), PCWP (26.4+/-6.6 mm Hg), and V-wave amplitude (39.1+/-14.6 mm Hg) were similar before and after either RVA or RVOT pacing. In contrast, LV-based pacing (either LV alone or BIV pacing) resulted in higher SBP (P<.03) and lower PCWP (P<.01) and V-wave amplitude (P<.001) than either baseline or RV pacing measurements. With LV pacing alone, SBP, PCWP, and V waves were 126.5+/-15.1, 20.7+/-5.9, and 25.5+/-8.1 mm Hg, respectively. The results with LV pacing alone were similar to those obtained with BIV pacing. CONCLUSIONS: In patients with severe congestive heart failure, both LV pacing alone and BIV pacing resulted in a similar and significant acute improvement in SBP, PCWP, and V-wave amplitude compared with baseline measurements and RV pacing alone. These results provide a strong basis for initiating long-term studies examining the chronic effects of LV-based pacing in patients with medically refractory congestive heart failure.

Adult

Termination of implantable pacemaker therapy: experience in five patients.

BACKGROUND: Established guidelines direct the initial implantation of permanent pacemakers. Elective replacement of these devices is common. However, no guidelines exist for the removal of permanent pacemakers and the termination of long-term cardiac pacing. OBJECTIVE: To describe the feasibility and safety of terminating cardiac pacing in carefully selected patients. DESIGN: Case series. SETTING: University hospital. PATIENTS: Five adults with permanent pacemakers who were referred for pacemaker replacement or a complication related to cardiac pacing. All patients showed alleviation or reversal of the electric disturbance that originally led to the implantation of the device. The patients had received a pacemaker for a class I or II indication (that is, symptomatic bradycardia or asymptomatic, persistent third-degree atrioventricular block at the level of the atrioventricular node). INTERVENTION: After an appropriate natural rhythm was documented, pacemakers were removed from all patients. MEASUREMENTS: Time without recurrence of symptomatic bradycardia. RESULTS: No patient had recurrent symptomatic bradycardia after 18 to 48 months of clinical follow-up. CONCLUSIONS: The presence of a permanent pacemaker does not necessarily imply a permanent need for cardiac pacing. Discontinuation of cardiac pacing may be considered in certain patients. Establishing consensus criteria about the potential indications, methods, and timing of the termination of cardiac pacing seems appropriate.

Adult

Clinical approach to diagnosis of syncope. An Overview.

Effective management of the syncope patient is critically dependent on excluding conditions in which altered consciousness is not due to syncope (e.g., seizure and sleep disorders) then establishing the basis for syncopal symptoms. The initial diagnostic step in syncope patients is differentiation of those individuals with normal cardiovascular status from those with structural heart disease. In the former, tilt-table testing and related studies of autonomic nervous system function are usually the most productive direction in which to proceed. In patients with structural heart disease, a functional assessment of the suspected structural disturbance (i.e., hemodynamic, angiographic, imaging as appropriate) and evaluation for susceptibility to symptomatic arrhythmias by monitoring or conventional electrophysiologic testing is appropriate. Autonomic function testing should follow if the diagnosis remains unclear. In only a few instances should specialized neurologic studies be undertaken as an initial step. The ultimate objective is always to obtain a sufficiently strong correlation between syncopal symptoms and detected abnormalities to feel confident in the diagnosis, permit an accurate assessment of prognosis, and develop an appropriate treatment plan.

Cardiovascular Diseases

Clinical experience with Thera DR rate-drop response pacing algorithm in carotid sinus syndrome and vasovagal syncope. The International Rate-Drop Investigators Group.

This study examined the effectiveness of cardiac pacing using the Thera DR rate-drop response algorithm for prevention of recurrent symptoms in patients with carotid sinus syndrome (CSS) or vasovagal syncope. The algorithm comprises both diagnostic and treatment elements. The diagnostic element consists of a programmable "window" used to identify heart rate changes compatible with an evolving neurally mediated syncopal episode. The treatment arm consists of pacing at a selectable rate and for a programmable duration. Forty-three patients (mean age 53 +/- 20.4 years) with CSS alone (n = 8), CSS in conjunction with vasovagal syncope (n = 4), or vasovagal syncope alone (n = 31) were included. Thirty-nine had recurrent syncope, while the remaining four reported multiple presyncopal events. Prior to pacing, 40 +/- 152 syncopal episodes (range from 1 to approximately 1,000 syncopal events) over the preceding 56 +/- 84.5 months. Postpacing follow-up duration was 204 +/- 172 days. Three patients have been lost to follow-up and in one patient the algorithm was disabled. Among the remaining 39 individuals, 31 (80%) indicated absence or diminished frequency of symptoms, or less severe symptoms. Twenty-three patients (23/29, or 59%) were asymptomatic with respect to syncope or presyncope. Sixteen patients had symptom recurrences. Of these, seven experienced syncope (7/39, or 18%) and 9 (29%) had presyncope: the majority of patients with recurrences (6/7 syncope and 7/9 presyncope) were individuals with a history of vasovagal syncope. Consequently, although symptoms were observed during postpacing follow-up, they appeared to be of reduced frequency and severity. Thus, our findings suggest that a transient period of high rate pacing triggered by the Thera DR rate-drop response algorithm was beneficial in a large proportion of highly symptomatic patients with CSS or vasovagal syncope.

Adolescent