PubMed Health⌕ Search

Biomedical subjects

D G Heidemann

Publications and source records attributed to D G Heidemann.

22 records · Page 2Linked to original sources

Comparative tonometric measurements of eye bank eyes.

A comparison was made of the accuracy of the Tono-Pen, Pneumatonometer, and Perkins hand-held tonometers by measuring the hydrostatically controlled intracular pressure from 10 to 50 mm Hg in human eye bank eyes. The open stopcock method was used in which the cannulated eye, the hydrostatic pressure controlling column, and a manometer were continuously open to each other. The Pneumatonometer gave accurate results at 50 mm Hg but overestimated the lower intraocular pressures; whereas, the Perkins gave satifactory results at 10 and 20 mm Hg but underestimated higher intraocular pressures. The Tono-Pen displayed the least deviation from the controlled pressure over the entire range studied. Another aspect of this study involved determining that a therapeutic soft contact lens did not have any noticeably adverse effect on the accuracy of the Pneumatonometer and Tono-Pen tonometers.

Contact Lenses, Hydrophilic↗

Oversized donor grafts in penetrating keratoplasty. A randomized trial.

One hundred seventy-three aphakic or phakic corneal transplants were analyzed in a prospective randomized study to determine the effect of oversized corneal donor buttons on intraocular pressure, corneal curvature and astigmatism, wound dehiscence, and anterior chamber depth. We compared 93 oversized grafts with 80 same-sized grafts. In aphakic eyes, oversized grafts showed a trend toward lower incidence of elevated intraocular pressure during the early post-operative period and lower prevalence of glaucoma at the final visit, although this was not statistically significant. No such trends were seen in phakic eyes. Postoperative corneal curvature was significantly steeper in oversized than same-sized grafts, in both phakic and aphakic eyes; there was no difference in postoperative astigmatism. Anterior chamber depth was significantly greater in oversized grafts. Of four wound dehiscences, all occurred in same-sized grafts.

Aphakia↗

Retinitis pigmentosa. A mimic of neurologic disease.

Six patients with various forms of retinitis pigmentosa who were misdiagnosed as having neurologic disease are presented. In five of the patients, visual field defects were misinterpreted as being secondary to a neurologic rather than a retinal problem. In two patients, optic nerve drusen, which accompanied the retinal degeneration, were mistaken for papilledema. Since the diagnosis of retinitis pigmentosa is not always obvious on ophthalmoscopy, the clinician must be aware of the various manifestations of this disorder and be able to distinguish visual field defects on a retinal from a neurologic basis.

Adolescent↗

Endophthalmitis after radial keratotomy enhancement.

A 45-year-old man developed endophthalmitis after a radial keratotomy (RK) enhancement. He developed severe intraocular inflammation, hypopyon, and dense vitreous membranes 4 days after the enhancement surgery. Cultures of the corneal wound yielded a heavy growth of Streptococcus viridans. The inflammation subsided after treatment with intraocular, intravenous, and topical antibiotics. The patient subsequently developed a cataract and retinal detachment. This case demonstrates the risk of endophthalmitis after RK enhancement.

Anterior Chamber↗