The Georgia experience: unifying state and local services around the balanced service system model.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to D G Miles.
Explore the source record for details and available documents.
Male sexual dysfunction after aortoiliac operations can be a distressing complication. Since previous studies dealing with this problem have not excluded other causes of sexual dysfunction, the true incidence of this complication has been difficult to ascertain. We assessed preoperative and postoperative sexual function in a group of patients with no identifiable organic or functional etiology of sexual dysfunction other than aortoiliac operations or arterial occlusive disease. Seventy-six male patients had no evidence of sexual dysfunction of ambiguous etiology before or after operation. Preoperatively, 33% of patients with abdominal aortic aneurysm and 22% of those with aortoiliac occlusive disease were functionally impotent. Conventional dissection techniques rendered an additional 30% of each group functionally impotent. Postoperative impotence was twice as common in those with minor dysfunction preoperatively.
We report a method for simultaneous measurement of five commonly used tricyclic antidepressant drugs (doxepin, desipramine, nortriptyline, imipramine, and amitriptyline) in serum by paired-ion high-performance liquid chromatography, with use of a reversed-phase column and ultraviolet detection at 254 nm. The drugs are extracted from 2 ml of serum at pH 14 into hexane/isoamyl alcohol (99/1 by vol) and re-extracted into 200 microliter of 0.1 mol/liter HCI. An aliquot of the aqueous acid phase is chromatographed with use of a methanol/acetonitrile/water (41/15/44) solvent system, containing 5 mmol of pentanesulfonic acid per liter of phosphate buffer (0.1 mol/liter, pH 6.5), at a flow rate of 1,5 ml/min. Analytical recoveries of the drugs from serum increase with increasing concentration, from 62% at 25 microgram/liter to 93% at 300 microgram/liter. Linear response is observed for drug concentrations up to 1500 microgram/liter and the detection limit is 2-3 microgram/liter. Within-run precision ranges from 1.4 to 2.9% and day-to-day precision from 1.7 to 7%, depending on the specific drug. The entire procedure can be completed within 45 min and is well adapted to the routine clinical laboratory. Of 48 common basic and several neutral drugs tested for possible interferences, only three benzodiazepines, three phenothiazines, and three antihistamines interfere with the assay of doxepin, desipramine, and nortriptyline, respectively.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.