PubMed HealthSearch

Biomedical subjects

D G Stuart

Publications and source records attributed to D G Stuart.

At least 19 recordsLinked to original sources

Fatigue-related changes in motor unit action potentials of adult cats.

The purpose of this study was to quantify the changes in motor-unit action potentials (MUAP) and force during a standard motor-unit fatigue test. MUAP waveforms were characterized by the measurement of amplitude, duration, area, and shape (as reflected in a coefficient of proportionality). Fatigue-resistant motor units exhibited small, but statistically significant, changes in MUAP amplitude and area during the fatigue test, whereas fatigable motor units displayed variable changes in MUAP amplitude, duration, and area. For all motor-unit types, the coefficient of proportionality did not change, and hence the change in MUAP area was proportional to the combined changes in amplitude and duration. The between- and within-train changes in MUAP were also distinct for the fatigue-resistant and fatigable motor units. Although several mechanisms could be responsible for the changes in the MUAP as the fatigue test proceeded, the dissociation of the time courses for MUAP and force indicated that these MUAP changes were not the principal reason for the decline in force under these conditions.

Action Potentials

The effect of the stimulation pattern on the fatigue of single motor units in adult cats.

1. The main purpose of this study was to examine the effects of two subtly different stimulus patterns on the force developed by fast-twitch, fatiguable motor units in a cat hindlimb muscle during control (pre-fatigue) and fatiguing contractions. 2. The peak force and the force-time integral responses of nineteen high fatigue (FF) and three intermediate fatigue (FI) motor units of the tibialis posterior muscle in five deeply anaesthetized adult cats were measured at selected times during the course of a 360-s fatigue test. 3. The fatigue test involved a pseudo-random alternation of two patterns of stimulation. One pattern (regular) was composed of a train of stimuli with constant interpulse intervals, set at 1.8 x the twitch contraction time of each unit (interval range, 27-51 ms), and delivered for 500 (or 400) ms. For the total (FF + FI) motor-unit sample, the mean (+/- S.D.) stimulation frequency was 26 +/- 4 Hz (range, 19-37 Hz). The other stimulus pattern (optimized) consisted of three initial stimuli with short (10 ms) interpulse intervals, followed by a constant interpulse-interval train that was adjusted (interval range, 29-62 ms; frequency, 23 +/- 5 Hz; frequency range, 16-36 Hz) such that the total train had the same number of pulses, and the same average frequency and duration as the regular train. 4. The stimulus trains were delivered at 1 s-1 for 360 s, using three-train sequences of each pattern, randomly alternating with one another. The response of the third train in each sequence was selected for the force measurements. The force profile obtained from the fatigue test was subsequently decomposed into two profiles: one attributable to regular and one to optimized stimulation. 5. During the initial responses to the fatigue test, the optimized stimulus pattern produced significantly more force than the regular stimulus pattern. For FF units, the mean increase in peak force (141%) was significantly greater than the increase in the force-time integral (59%). 6. All motor units exhibited an initial potentiation of peak force with the regular stimulation pattern, whereas peak force declined monotonically with the optimized pattern. In contrast, the force-time integral potentiated in the first 30 s for both regular and optimized stimulus patterns. 7. Each motor unit maintained an increased force response to optimized stimulation during the fatigue test, with the greatest relative increase occurring about 120 s into the test, well after the potentiation effect had subsided.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals

Neurobiology of muscle fatigue.

Muscle fatigue encompasses a class of acute effects that impair motor performance. The mechanisms that can produce fatigue involve all elements of the motor system, from a failure of the formulation of the descending drive provided by suprasegmental centers to a reduction in the activity of the contractile proteins. We propose four themes that provide a basis for the systematic evaluation of the neural and neuromuscular fatigue mechanisms: 1) task dependency to identify the conditions that activate the various mechanisms; 2) force-fatigability relationship to explore the interaction between the mechanisms that results in a hyperbolic relationship between force and endurance time; 3) muscle wisdom to examine the association among a concurrent decline in force, relaxation rate, and motor neuron discharge that results in an optimization of force; and 4) sense of effort to determine the role of effort in the impairment of performance. On the basis of this perspective with an emphasis on neural mechanisms, we suggest a number of experiments to advance our understanding of the neurobiology of muscle fatigue.

Animals

Immobilization-induced changes in motor unit force and fatigability in the cat.

The purpose of this study was to examine the effects of 3 weeks of immobilization on the mechanical properties of motor units in a cat hindlimb muscle. The muscle, tibialis posterior, was immobilized in a shortened position. Motor units were classified as type FF, F(int), FR, or S. Force, axonal conduction velocity, fatigability, and proportions of motor unit types were compared in control and immobilized muscles. All properties exhibited some change after immobilization, including slower axonal conduction velocities, greater twitch forces, slower twitch contraction times, and greater tetanic forces. In addition, most motor units were less fatigable after immobilization. The number of motor units that could not be included in one of the four classification categories increased significantly after immobilization; these units exhibited normal axon conductivity but failed to produce measurable force or associated EMG. Short-term immobilization induced a variety of physiological adaptations in neuromuscular processes that varied with motor unit type.

Action Potentials

Measurement systems calibration: microcomputer implementation.

Measurement systems used in the collection and processing of laboratory data must be calibrated periodically to obtain accurate results. Because calibration factors can change over time or may be reset to optimize measurements for specific tests, care must be taken to assure that calibration factors and data are aligned correctly. Users should be able to process current data or re-process older data using appropriate calibration factors. The alignment of calibration factors and data should occur in a simple, automatic and transparent way. This document describes one approach to calibration procedures and computer programs used to collect, process, document, measure and display laboratory data. The examples are from our neurophysiology laboratory, where investigators study the mammalian spinal cord and peripheral neuromuscular system. Typical calibration problems, some workable solutions, and computer programs (described in pseudocode) are presented.

Calibration

Computer-aided extraction of the features of the EMG of single motor units.

A software-based system is presented for feature extraction of compound, action-potential (EMG) recordings from single motor units. It simplifies and automates the measurement and analysis of several parameters of the action potential: peak-to-peak amplitude, total duration, peak-to-peak duration, and total area. The software is based on a simple algorithm that first finds the baseline (isoelectric line; including a noise level) of each single EMG potential (waveform) and then searches for the minimum and maximum values in the array of data points representing it. The algorithm searches in both directions starting from the minimum and maximum data points (the waveform peaks) to find the beginning and ending points of the waveform. Using the indices (i.e., array-point numbers) of the four data points provided by the algorithm, the desired features are extracted and/or calculated and saved in a standard-format spreadsheet. The algorithm has a potentially widespread usefulness in a broad array of electrophysiological studies.

Action Potentials

Motor-unit force potentiation in adult cats during a standard fatigue test.

1. The purpose of this study was to examine the time course of tetanic force during a standard fatigue test and to distinguish between the appearance of potentiation and fatigue among the four motor-unit types of a cat hindlimb muscle. 2. Motor units of the tibialis posterior muscle in the adult cat were assigned to four categories (i.e. types S, FR, FI, FF) based on conventional criteria (Burke, Levine, Tsairis & Zajac, 1973). The mean (+/- S.D.) time course of peak force was constructed for each motor-unit type and, within each type, for those units that potentiated (a greater than 3% increase in peak force compared to the initial value) and those that did not potentiate. 3. The average time courses of force differed between motor-unit types. There was, however, considerable variability within each motor-unit type. For the same relative force output, the forces exerted by slow-twitch units were less variable than those exerted by fast-twitch units. In addition, the variability among slow-twitch units was relatively constant during the fatigue test while variability among fast-twitch units either increased or decreased with time. 4. For a given motor-unit type, the average time course of force did not depend on whether force in each tetanus was expressed as a peak value, an average peak value, or a force-time integral. 5. Some motor units within each type exhibited potentiation. Most of the variability in the time course of the peak force for each motor-unit type could be accounted for by the potentiating units. Motor units that exhibited only force decline (i.e. fatigue), regardless of unit type, had less variable time courses of peak force. Since potentiation was transient in some unit types, it was assumed that at least two opposing processes (i.e. fatigue and potentiation) occurred simultaneously in these units (see also, Krarup, 1981; Rankin, Enoka, Volz & Stuart, 1988; Garner, Hicks & McComas, 1989). 6. It is concluded that the expression of force potentiation throughout a fatiguing regimen is variable among motor units and that this is not related to conventional motor-unit types. This dissociation suggests that the mechanisms that form the basis for the conventional distinction between motor-unit types are different from those which lead to force potentiation.

Anesthesia, Intravenous

Force development and relaxation in single motor units of adult cats during a standard fatigue test.

1. The purpose of this study was to investigate tetanic force development and relaxation in single motor units that were subjected to a standard fatigue test. 2. Motor units of tibialis posterior, a hindlimb muscle in the adult cat, were assigned to four categories (i.e. types S, FR, FI, FF) using conventional criteria. 3. Based on the first tetanus of the fatigue test, type S units took significantly longer to develop force and to relax than the fast-twitch units. Within the fast-twitch subpopulations, type FR and FI units were significantly slower to develop force and to relax than were type FF units, but there were no significant differences between type FR and FI units. 4. After 120 s of the fatigue test, the rates of force development were faster than initial values in type S and FR units, but were largely unchanged for the type FI and FF units. Most relaxation parameters were unaffected by stimulation in type S and FR units, but all parameters became significantly slower in type FI and FF units. 5. The average time courses of force development and relaxation showed that during 240 s of the fatigue test, type S units exhibited either a progressive increase in a parameter or no change at all. In contrast, fast-twitch units displayed profiles that included initial increases in a force development or relaxation parameter followed by variable amounts of decline that corresponded to fatigability. 6. It is concluded that repetitive activation affects the development and relaxation of tetanic force in all motor-unit types. Average changes in these parameters tended to parallel the conventional classification of motor units into four categories.

Animals

Fatigability of rat hindlimb muscle: associations between electromyogram and force during a fatigue test.

1. An experimental protocol designed to assess fatigability in motor units (Burke, Levine, Tsairis & Zajac, 1973) has been applied to the whole muscles of anaesthetized adult rats, and the association between the electromyogram (EMG) and force was monitored over the course of the test. 2. Both test muscles (soleus and extensor digitorum longus) exhibited a wide range of fatigability, which was defined as the decline in isometric peak force at 6 min, such that the data could be separated into five levels of fatigability. Fatigue indices for each test muscle were distributed across three levels. 3. The EMG was quantified with four measures of amplitude, four of duration, and one interaction term (area). Correlation analyses indicated that the EMG was adequately represented by one measure of amplitude (absolute amplitude), one of duration (peak-to-peak duration) and area. The best single measure was area. 4. The EMG-force associations for soleus varied markedly among its three fatigability groups. In contrast, over the course of the test, all three extensor digitorum longus groups displayed qualitatively similar EMG-force associations. 5. Multiple regression analyses indicated that the EMG parameters were able to predict peak force better for extensor digitorum longus than for soleus. Furthermore, for both test muscle, the prediction was best for the most fatigable group. 6. The associations between EMG and force exhibited three patterns for the two test muscles and three levels of fatigability. These differences suggested variation in the mechanisms, related to both fibre-type composition and susceptibility to fatigue, that dictate the performance elicited by this particular stimulus regimen. The mechanisms seem to include both intracellular and transmission processes.

Action Potentials

Effects of chloralose-urethane anesthesia on single-axon reciprocal Ia IPSPs in the cat.

Reciprocal Ia inhibitory postsynaptic potentials (IPSPs) generated by single afferents have been recorded with signal averaging in unanesthetized ischemic-decapitate cats for comparison with measurements previously obtained from preparations anesthetized with a mixture of chloralose and urethane. The results are similar to those which we obtained recently for single-axon recurrent IPSPs. Together, the studies show that chloralose-urethane anesthesia has a depressant effect on two widely studied circuits in the mammalian spinal cord.

Anesthesia

Association between biochemical and physiological properties in single motor units.

Motor units from the cat tibialis posterior muscle were examined for an association between physiological and biochemical properties. Functionally isolated motor units were categorized on the basis of their physiological properties. This was followed by quantitative microbiochemical analysis of single muscle fibers from each unit, identified in cross sections using the glycogen-depletion method. The activities of malate dehydrogenase and beta-hydroxyacyl-CoA dehydrogenase distinguished between fatigable (type FF) and fatigue-resistant (types FR and S) units. The activities of both lactate dehydrogenase and adenylokinase were higher in fast- than in slow-contracting units. Cluster analyses, based on both physiological and biochemical properties or on biochemical properties alone, produced groupings identical to types FF, FR, and S. The association between physiological and biochemical properties substantiates the idea that biochemically distinct groups of motor units correspond to physiologically identifiable groups.

3-Hydroxyacyl CoA Dehydrogenases

Fatigue-related changes in neuromuscular excitability of rat hindlimb muscles.

Brief repetitive trains of supramaximal nerve stimulation produce intermittent muscle activation and, in time, a progressive decline in force (i.e., neuromuscular fatigue) and depression of the electromyogram (EMG). These changes may include within-train reductions in EMG due to a failure of neuromuscular propagation. The aim of the present study was to investigate changes in EMG during a 360-second stimulus regimen designed to fatigue soleus and extensor digitorum longus muscles of anesthetized rats by activating the muscle with repetitive trains of 40 Hz stimuli. Measurements included peak force for each tetanus, variation of the within-train EMG (coefficient of variation for area), and magnitude of the first EMG waveform (area) of each train. Fatigue was characterized as the relative decline in force over the course of the test. The responses of the test muscles were categorized, based on an absolute scale of fatigability, into five groups: potentiated, nonfatigable, low fatigability, intermediate fatigability, and high fatigability. Fatigable muscles (low, intermediate, and high fatigability groups) demonstrated a decreased EMG magnitude and an increased EMG-area variation with repetitive activation. This increased variation, however, was nonmonotonically related to fatigability such that the least and most fatigable muscles had the smallest within-train EMG variation. We suggest that these data can be explained by considering the EMG (compound muscle action potential) as a stochastic process that represents a composite of single-fiber events (axonal to sarcolemmal transmission) with variable probabilities.

Animals

Coexistence of twitch potentiation and tetanic force decline in rat hindlimb muscle.

An experimental protocol designed to assess fatigability in motor units has been applied to two hindlimb muscles of anesthetized adult rats to study the effects of whole-muscle fatigue on the isometric twitch. Both soleus and extensor digitorum longus exhibited a linear relationship between fatigability (i.e., force decline after a 360-s fatigue test) and the magnitude of the twitch force following the fatigue test. Twitch force after the fatigue test was potentiated (i.e., greater than the value before the fatigue test) in many muscles, despite the development of considerable fatigue. This coexistence of fatigue and twitch potentiation was observed in 7% (5/70) of soleus and 48% (31/64) of extensor digitorum longus muscles. The coexistence was exhibited only by the least fatigable muscles of the fast-contracting extensor digitorum longus. The extensor digitorum longus muscles that did not exhibit twitch potentiation probably experienced a higher proportion of muscle-fiber inactivation, such as due to failure of neuromuscular propagation, that was induced by the fatigue regimen.

Animals

Activation of muscle fibers in individual motor units revealed by 2-deoxyglucose-6-phosphate.

Motor units of the cat tibialis posterior muscle were selectively activated by prolonged electrical stimulation of functionally isolated motor axons in situ. During the activation, the glucose analog 2-deoxyglucose (DG) was administered systemically. Single muscle fibers were subsequently examined for accumulation of the metabolite 2-deoxyglucose-6-phosphate (DG6P) by an analytical assay and for depletion of glycogen by a PAS glycogen-specific staining reaction (periodic acid Schiff; PAS). In general, levels of DG6P were 20 times greater in unstained (PAS-negative) fibers compared with stained (PAS-positive) fibers. However, some glycogen-depleted fibers, particularly in putative ischemic fascicles of the muscle, did not have elevated DG6P, suggesting that depletion of glycogen is not always a reliable indicator of fiber activation. Furthermore, the PAS-staining reaction was not necessarily indicative of quantitative glycogen levels in single fibers. Thus, this report shows that DG6P accumulation enhances the identification of motor-unit fibers selectively activated via their common motor-nerve axon. Evidence is also presented for differential glucose uptake in muscle fibers of different phenotype, thereby indicating that the DG6P measurement in muscle has broad applicability to the investigation of cellular glucose utilization.

Animals