PubMed Health⌕ Search

Biomedical subjects

D G Stuart

Publications and source records attributed to D G Stuart.

At least 91 records · Page 5Linked to original sources

Correlation analysis of muscle spindle responses to single motor unit contractions.

1. Cross-correlation techniques have been used to study the responses of muscle spindle afferents from the soleus muscle of the cat to twitch contractions of single motor units. 2. Cross-correlograms (post-stimulus time histograms) were used to give the frequency of occurrence of a receptor spike at various times following the initiation of a motor unit contraction together with a display of the average twitch tension wave form. 3. The cross-correlograms revealed that the contraction of a single motor unit can be an effective stimulus to a spindle receptor and may induce afferent firing pattern alterations similar to those observed with whole muscle contraction. 4. The cross-correlograms also revealed quantitative differences in the response of a receptor to contraction of different motor units and to contraction of the same motor unit at different lengths. These differences reflect subtle changes in receptor deformation developed by the twitch of a motor unit under different conditions and by the twitches of different motor units. The results are consistent with anatomical data on the number and distribution of motor units and receptor organs in cat soleus. 5. These findings emphasize that rather than simply acting as generalized force or length sensors for the muscle as a whole, each receptor's spike train carries information about the state of a particular set of motor units.

Afferent Pathways↗

Aquatic indicator bacteria in the high alpine zone.

Selected waters from the high alpine zone within Grand Teton National Park, Wyoming, were analyzed for populations of indicator bacteria during the past three summers to determine the influence of various factors on the quality of these waters. In general the water quality was not significantly influenced by the presence or absence of human visitors but rather by the nature of the biological community through which the streams flowed. A minority of the coliforms that were recovered from all of the sites proved to be fecal coliforms. The fecal streptococci isolated were identified as the species that were found primarily in the fecal material of the native rodent and moose populations. It is concluded that management questions that relate to the carrying capacity of alpine areas should be approached with the aid of other biological parameters along with levels of indicator bacteria in the streams.

Altitude↗

Kinematics of locomotion by cats with a single hindlimb deafferented.

1. Cinematographic measurements were made of stepping by cats on a motor-driven treadmill, both normally and 2-3 wk after deafferentation of the LH (left hind) limb. 2. After surgery, rhythmic cycling of the LH limb was blurred whether the leg was dragged, as by some cats, or if it was lifted from the surface, as by others. 3. Interlimb coordination was also blurred with respect to normal, although distinct rhythms were still seen. The RH (right hind) limb descended prematurely and, in the walk, had a prolonged stance phase. The interval between touchdowns of hind- and forelimb on the left side no longer equaled that interval on the right side. 4. As is true for a normal cat, if the LH-deafferented animal stumbled, relatively normal single and interlimb cyclings were regained after several strides. 5. By kinematic analysis, force deficits were found in the deafferented LH limb both during the stance, when extensors should be most active, and the swing, when the limb failed to attain a normal position above the surface of the belt. Weight bearing by the LF (left fore) limb was altered in some animals. 6. At high speed, mean LH stance duration failed to decrease in the normal fashion. Inter-limb timings were reset to greater extent than in low-speed walking, as if the LH limb was being used only minimally. 7. It was concluded that both rhythm and force were impaired in the deafferented limb and also in the three intact limbs, whose weight bearing had to compensate for LH weakness. The changed mechanical demands after surgery were probably met by interactions between the remaining afferent input and central pattern generators so as to secure fairly effective and expedient locomotion.

Afferent Pathways↗

Analysis of muscle receptor connections by spike-triggered averaging. 1. Spindle primary and tendon organ afferents.

1. The synaptic connections of 44 single identified muscle spindle Ia afferents and of 21 Golgi tendon organ (Ib) afferents from medial gastrocnemius (MG) were studied in 46 cats by the spike-triggered averaging of synaptic noise in 803 motoneurons of various types. 2. The well-known monosynaptic Ia excitatory connections were confirmed and their characteristics examined in 113 cells. The method was used at greater sensitivity than before and revealed that, in addition to the larger EPSPs of the order of 300 muV, there were many below the previously reported lower 17-muV limit. 3. By studying the Ia disynaptic inhibitory pathway with quick stretch-evoked Ia volleys and by spike-triggered averaging (STA), it was shown that the latter method can reveal disynaptic and possibly trisynaptic excitatory connections. This is believed to depend on having continuous activity in the relevant interneurons. 4. Latencies of individual connections showed broad distributions and arguments are advanced for setting working limits to mono- and disynaptic paths for Ia excitation and inhibition. Monosynaptic EPSP latency from cord entry was 0.4-1.1 ms and disynaptic inhibition was 1.2-2.4 ms. It was recognized that the boundaries are not rigid and monosynaptic Ia EPSPs may have latencies up to 1.5 ms. 5. Rise times of disynaptic PSPs were, on average, significantly longer than monosynaptic, but individual disynaptic responses could have values within the monosynaptic range. 6. A small diphasic wave shortly preceding the monosynaptic EPSPs was interpreted as a presynaptic spike. Its timing was consistent with this and, as such, permitted estimates to be made of central conduction time. 7. An early negative wave (latency less than or equal 1.1 ms) of small emplitude was sometimes detected in antagonist motoneurons when triggering from Ia afferents. It was found tha extracellular fields could be detected due to single Ia afferent excitations and efforts were made to see if the early negative wave could be explained by this. In a few cases there was evidence that a very short-latency IPSP might be occuring. This evidence and its implications are discussed with attention to the new factors which have to be considered in using the spike-triggered averaging method at very high sensitivity. 8. Ib effect were di- or trisynaptic. They were excitatory to 18% of synergists and to 28% of antagonists. They were inhibitory to 41% of synergists and to 19% of antagonists. The Ib IPSPs were larger than the EPSPs.

Animals↗

Analysis of muscle receptor connections by spike-triggered averaging. 2. Spindle group II afferents.

1. The spike-triggered averaging (STA) method has been used to study synaptic connections of nine spindle group II afferents from medial gastrocnemius to 151 motoneurons of leg muscles in the cat. 2. EPSPs were found in 40 cells, predominantly of triceps surae with latency from cord entry ranging from 0.3 to 4.2 ms. Those with latency less than or equal to 1.4 ms were deduced to be monosynaptic in confirmation of Kirkwood and Sears (13). Mean amplitude for MG-LGS cells was 30.1 muV and mean rise time 1.0 ms (compared with 65.4 muV and 1.0 ms for monosynaptic Ia EPSPs from the preceding report (26)). It is argued that monosynaptic latency for spindle group II afferents could be as large as 1.65 ms. 3. The occurrence of a presynaptic spike permitted the division of EPSP latencies into central conduction time and synaptic delay components. Sindle group II central conduction times were significantly longer than those of Ia afferents, while there were no differences in the synaptic delays associated with the two afferent types. 4. EPSPs of longer latency were judged to be di- or trisynaptic. They were smaller and had longer rise times than the monosynaptic effects. Evidence is presented to show that short rise time of an individual PSP does not guarantee that it is monosynaptic. Rise times are different only on a population basis. 5. Inhibitory responses were found with latencies and mean rise times appropriate for di- and trisynaptic connections. Their mean amplitude was 4.6 muV. 6. The distribution of EPSPs and IPSPs was generally consistent with their exerting stretch reflex effects similar to that of Ia afferents and inconsistent with the inclusion of them in the grouping known as "flexor reflex afferents."

Animals↗

The motor units of cat medial gastrocnemius: problem of their categorisation on the basis of mechanical properties.

The mechanical properties of 126 motor units from medial gastrocnemius muscle have been studied in 12 adult cats. Units with long contraction times (greater than 45 msec) were non fatigable (24 out of 26 units) and small (25 out of 26 units with less than or equal to 0.3% of the parent whole muscle tetanic tension) thus forming a very homogeneous population. In contrast, fast twitch units (contraction time less than or equal to 45 msec) exhibited a very broad range of tetanic tensions and fatigability. Significant correlations were found, however, within the fast contracting population which indicate a tendency for the more fatigable units to develop more tetanic tension and to be faster contracting. These findings are discussed in relation to the problems associated with using the interrelationships between twitch contraction time, tetanic tension and fatigue resistance to classify motor units into subpopulations sharing similar mechanical properties.

Animals↗

The motor units of cat medial gastrocnemius: speed-size relations and their significance for the recruitment order of mortor units.

The interrelationships between axonal conduction velocity, tetanic tension, twitch contraction time and rate of force development during a tetanus have been studied in 126 motor units from 12 cat medial gastrocnemius muscles. While the range of axonal conduction velocities for slow- (contraction time greater than 45 msec) and fast-twitch units overlapped, the mean conduction velocity for the slow-twitch group was significantly lower. No difference could be found between the axonal conduction velocities of the fast non-fatiguing and fast fatiguing units. Within individual experiments, few significant correlations were found between conduction velocity and tetanic tension or contraction time for the fast- and slow-twitch units. Some correlations did appear when data from these populations were pooled, but such results are shown to be misleading. Some weak correlations were found between motor unit contraction strength and twitch contraction time. The rate of rise of isometric force development was found to be most strongly related to tetanic tension and only weakly related to contraction time. The ordering of motor units according to contraction strength reveals the association of motor unit mechnical properties to be ideally suited for the dual role of medial gastrocnemius as a postural and powerful phasic muscle.

Animals↗

The motor units of cat medial gastrocnemius: electrical and mechanical properties as a function of muscle length.

The effects of changing muscle length on the mechanical properties of 89 motor units from adult cat medial gastrocnemius have been studied in eight experiments. Few differences were found between the effects of length on tetanic tension, twitch tension, twitch-tetanus ratio, twitch contraction time, twitch half relaxation time, rate of force development and electrical activity for fast contracting (twitch contraction time less than or equal to 45 msec) and slowly contracting (greater than 45 msec) units. Those differences that did appear did not persist when these two groups were matched by tetanic tension. It is concluded that the biophysical mechanisms responsible for the changes in mechanical and electrical properties with length must be similar for fast and slow twitch units and not related to potential differences in their muscle fiber type. The effects of changing muscle length on the mechanical properties of the eight whole muscles suggest that changes in force output with length are of minor importance during normal movements as the muscle is found to be electrically active over a relatively narrow range of lengths close to the optimum length for tetanus of the whole muscle. The very shortest muscle lengths at which there is only minimal force development are not used in natural movements, while the declining limb of the length tension curve is at muscle lengths beyond the maximum in situ length.

Animals↗

The motor units of cat medial gastrocnemius. Twitch potentiation and twitch-tetanus ratio.

Twitch potentiation and the associated changes in contraction time and 1/2 relaxation time have been studied in a sample of 78 medial gastrocnemius motor units from 8 cats. Potentiation was produced by repetitive stimulation of the motor units every 10 sec with a brief tetanus followed 2 sec later by a twitch. Fast twitch fatigue resistant units were found to potentiate more strongly than either slow twitch (contraction time greater than 45 msec) or fast twitch fatigable units. It is concluded that Type C muscle fibres are more susceptible to potentiation than either Type A or Type B fibres. In a sample of 88 motor units from the same experiments, values for twitch/tetanus ratio were compared amongst units sharing similar mechanical properties. Slow contracting units developed small tetanic tensions and had small twitch/tetanus ratios. Fast twitch non fatigable units had intermediate values for contraction strength and twitch/tetanus ratio overlapping the ranges found for both the slow twitch and the more powerful fast twitch fatigable units. It is concluded that differences in twitch/tetanus ratio for medial gastrocnemius motor units are primarily related to motor unit contraction strength rather than differences in muscle fibre type.

Animals↗

The tendon organs of cat medial gastrocnemius: significance of motor unit type and size for the activation of Ib afferents.

1. Histological and histochemical studies suggest that each tendon organ in a mixed mammalian muscle should be particularly responsive to the contraction of a discrete number of motor units (ca. ten to fifteen), each with differing mechanical properties. This report describes physiological experiments that demonstrate this arrangement for the tendon organs of cat medial gastrocnemius. 2. No correlations could be found between the intensity of discharge of a single tendon organ and the contraction strengths of motor units whose contraction excited the receptor. Tendon organs were found to be as responsive to contraction of small slow twitch units as they were to contraction of larger fast twitch units. Taking the data as a whole, the apparent sensitivity of the receptors during motor unit contractions (pps/force recorded at the tendon) was inversely related to the contraction strengths of the motor units. 3. These findings are discussed in relation to recent evidence on the territory of single motor units in medial gastrocnemius and the force producing capabilities of their individual muscle fibres. It is concluded that in general each motor unit, whose contraction excites a given receptor, contributes one muscle fibre to the receptor capsule. Further, it appears that the various excitatory effects of those muscle fibres inserting into a given receptor capsule are not simply related to their relative contraction strengths but also depend on the details of the mechanical coupling between each fibre and the Ib afferent receptor endings. 4. The results of an ensemble analysis show that despite the lack of correlation between the intensity of tendon organ discharge and the force developed at the tendon during contraction of different motor units, a correlation does appear when the responses of several tendon organs and the forces developed by the motor units which excite them are summed progressively. This finding has implications for the recruitment order of motor units in that the profile of the collective Ib response is shown to differ according to whether motor unit forces are summed randomly or in order of increasing contraction strengths.

Action Potentials↗

Influence of environmental stress on enumeration of indicator bacteria from natural waters.

The problems associated with recovery of pure cultures of Escherichia coli and Streptococcus faecalis from stream environments were examined utilizing membrane filter chambers. It was observed that upon exposure to the aquatic environment a significant proportion of cells lost their ability to produce colonies on a selective medium, yet retained this capability on a nutritionally rich, nonselective medium. Discrepancies in colony-forming units between nonselective and selective media indicated that a substantial portion of bacterial cells may become physiologically injured due to the environmental stress imposed by the aquatic environment. The extent of injury was observed to vary considerably among the eight different stream environments, since the amount of injury was not uniform for all types of water environments examined. It was observed that the injury acquired by a population of E. coli, during exposure to the aquatic environment, could be rapidly repaired in a nutritionally rich, nonselective medium. As the injured population of cells was exposed to the rich, nonselective broth, increasing proportions of cells were able to repair themselves such that they became insensitive to inhibitory agents in selective media.

Buffers↗

Tendon organs of cat medial gastrocnemius: responses to active and passive forces as a function of muscle length.

The responses of 13 Golgi tendon organs to graded force development of 29 motor units in medial gastrocnemius of the cat have been studied in five experiments. Of the 13 tendon organs, 11 were responsive to passive stretch within the physiological range of muscle length and 5 were "spontaneously" active at very short lengths where no passive tension could be recorded. The relationship between passive force and the firing rates of the various afferents ranged from a linear one to a power relation (Y = Axb + c) with b, a widely varying exponent. Results support the general conclusion that although many Ib afferents respond to passive force within the physiological range of muscle stretch, this form of stimulus is not a particularly effective one. The statis responses of Golgi tendon organs to active force development produced by single motor units was studied at different muscle lengths. In all cases the apparent sensitivity (change in firing rate per active force developed) decreased as muscle length approached Lo. The static responses of Golgi tendon organs to force developed by single motor units were also studied during fatiguing contractions. The data suggest a sigmoid relationship between force developed at the tendon and the Ib response. The collective response of all 13 tendon organs to active and passive forces at different muscle lengths was also examined. This analysis offered further support for the viewpoint that active motor unit contractions provide themost significant excitatory input to tendon organs and that changes in passive force during muscle stretch have comparatively little effect on the collective tendon organ response. The interaction between active and passive force inputs to the Golgi tendon organs is discussed in relation to the complicated nature of the relationship between forces measured at the tendon and those acting within the receptor capsule. When these complications were taken into account it was possible to explain the differences in responsiveness of a given tendon organ to active contraction of several motor units and to passive force in terms of a single force-firing rate curve for the receptor. It is concluded that changes in the force of contraction of single motor units result in relatively small changes in Ib afferent firing and that during normal muscle contractions, changes in the number of motor units acting on a single receptor must produce far more significant changes in firing rate than changes in the amount of force developed by any single unit. Changes in dynamic Ib sensitivity to single motor unit contractions are also shown to depend on length and in a similar way to the changes in static Ib sensitivity. During fatiguing contractions, a sigmoid relation was found between the dynamic Ib response and the rate of force development by single motor units.

Animals↗

Comparative survival of indicator bacteria and enteric pathogens in well water.

The comparative survival of various fecal indicator bacteria and enteric pathogens was studied in a stable well water supply by using membrane chambers. There was more variation in the 29 coliform cultures and they died more rapidly, as a group, than the 20 enterococcus cultures that were examined. The comparative survival of the organisms tested follows: Aeromonas sp. > the shigellae (Shigella flexneri, S. sonnei, and S. dysenteriae) > fecal streptococci > coliforms = some salmonellae (Salmonella enteritidis ser. paratyphi A and D, S. enteritidis ser. typhimurium) > Streptococcus equinus > Vibrio cholerae > Salmonella typhi > Streptococcus bovis > Salmonella enteritidis ser. paratyphi B. S. bovis had a more rapid die-off than did S. equinus, but both had significantly shorter half-lives than the other streptococci. The natural populations of indicator bacteria from human and elk fecal material declined similarly to the pure cultures tested, whereas the die-off of fecal streptococci exceeded the coliforms from bovine fecal material.

Aeromonas↗