PubMed Health⌕ Search

Biomedical subjects

D Glavic-Cindro

Publications and source records attributed to D Glavic-Cindro.

7 recordsLinked to original sources

Quality assurance of automated gamma-ray spectrometric analysis

Fully automatic gamma-ray spectrometric analysis procedures perform complete processing of the spectrum without intervention of the operator. In order to maintain the reliability of the final results the analysis checks the intermediate results automatically. When a disagreement is identified by such a check the uncertainty of the intermediate results is increased in order to accommodate the disagreement. The increased uncertainty is propagated into the uncertainty of the final results in order to take into account the disagreement. This approach was implemented in Canberra's Genie ESP gamma-ray spectrometry package for examining the results of the peak analysis. In addition to this intermediate check also a-posteriori checks of the final results can be performed by statistical analysis. Such analysis shows whether the results are under statistical control and can discover sources of variability which are not taken into account in the uncertainty budget.

Journal Article↗

Quality control of gamma-ray spectrometry measurements

Specific techniques have been implemented to assess the quality of routine gamma-ray measurements and the associated analysis procedures. Appropriate steps monitor three factors influencing the quality of performance: the performance of the spectrometer, the quality of the measurement and the quality of the peak analysis. In order to illustrate the approach, time dependencies of parameters describing the performance of the spectrometer, the quality of the measurements and the sample activities are presented.

Journal Article↗

IAEA Internet database of natural matrix reference materials.

The International Atomic Energy Agency maintains a database on internationally available certified reference materials of natural origin. The database was updated in 1998 and prepared for an Internet implementation. A user-friendly structure was created, providing two main pathways for browsing, either according to the matrix classification or the producer's name. The database presently contains over 20,000 values for 480 measurands and 1085 reference materials from 43 different producers. Most of the materials entered contain values for trace and minor elements (66%).

Database Management Systems↗

Towards establishing traceability of results measured in specific counting conditions in gamma-ray spectrometry.

Due to biased potassium activity results in the proficiency test soil samples, measurements of a set of control samples containing potassium compounds with known concentrations of potassium were performed in order to establish the traceability of potassium activity results in to the unit of mass. The radius and the mass of the control samples were equal to the radius and the mass of the proficiency test samples. The density of samples in both cases varied between 1 and 2g/cm(3). No influence of sample density on the potassium activity results could be detected at the accuracy level achieved. The source of disagreement could not be found within the participating laboratory.

Calibration↗