D Gröver

Publications and source records attributed to D Gröver.

2 recordsLinked to original sources

An abdominal wall simulator for testing suprapubic urinary catheters.

Urinary catheters (drainage tubes) are in widespread use. The most common type of long-term catheter is the Foley, which is made from natural or synthetic rubber. Foley catheters are passed into the bladder via the urethra or the suprapubic puncture channel (through the abdominal wall). A simulator for the abdominal wall has been developed to simulate aspects of the interaction between it and a suprapubic catheter. The simulator is based on a slab of ultrasoft elastomer with tensionable reinforcing polyamide filaments. The behaviour of the simulator has been compared with data published. A soft membrane (contact pressure) transducer (SMT) was used and novel instrumented 'tongs' for lateral indentation of the puncture track giving indentation stiffness. Slab materials were used with shear moduli of 0.1 and 0.021 MPa. Two filament-tensioning methods were used: by clamping to a winding mechanism and by weights. The combination of the softer slab material and tensioning by weights gave good conformity to physiological data; other combinations did not.

Abdominal Muscles↗

Suprapubic track pressure and force--deformation measurements in a (live) human subject and in animal models post-mortem.

Tests have been performed on animal models shortly post-mortem and on a healthy human subject in order to obtain estimates of the forces which act on suprapubic urinary catheters and similar devices and to develop an abdominal wall simulator. Such data and test methods are required for the systematic design of suprapubic devices because of the dual need to maintain the functionality of devices and to avoid excessive pressure on soft body tissue which could lead to ischaemia and in turn necrosis. In the post-mortem animal models, electrical excitation was applied to the abdominal wall in order to stimulate muscle activity. Two types of transducers were used: a soft membrane transducer (SMT) for pressure measurement and novel instrumented 'tongs' to determine indentation stiffness characteristics in the suprapubic track or artificial pathway created for a device. The SMT has been extensively used in the urethras and bladders of human subjects while the tongs were built specifically for these tests. Only the well-established SMT was used with the human subject; a peak pressure of 22 kPa was obtained. In the animal models the pressure profile given by the SMT had a peak whose position corresponded well with the estimated location of the rectus muscle measured on the fixed tissue section. The peak value was 5.5 kPa, comparable with values likely to cause necrosis if maintained for more than 1 day. Remarkably consistent indentation stiffness values were obtained with the instrumented tongs; all values were close to 0.45 N/mm (33 kPa/mm).

Abdominal Muscles↗