Triple-head gamma camera PET: system overview and performance characteristics.

Positron emission tomography (PET) is currently performed using either a dedicated PET scanner or scintillation gamma camera equipped with electronic circuitry for coincidence detection of 511 keV annihilation quanta (gamma camera PET system). Although the resolution limits of these two instruments are comparable, the sensitivity and count rate performance of the gamma camera PET system are several times lower than that of the PET scanner. Most gamma camera PET systems are manufactured as dual-detector systems capable of performing dual-head coincidence imaging. One possible step towards the improvement of the sensitivity of the gamma camera PET system is to add another detector head. This work investigates the characteristics of one such triple-head gamma camera PET system capable of performing triple-head coincidence imaging. The following performance characteristics of the system were assessed: spatial resolution, sensitivity, count rate performance. The spatial resolution, expressed as the full width at half-maximum (FWHM), at 1 cm radius is 5.9 mm; at 10 cm radius, the transverse radial resolution is 5.3 mm, whilst the transverse tangential and axial resolutions are 8.9 mm and 13.3 mm, respectively. The sensitivity for a standard cylindrical phantom is 255 counts.s(-1).MBq*(-1)), using a 30% width photopeak energy window. An increase of 35% in the PET sensitivity is achievable by opening an additional 30% width energy window in the Compton region. The count rate in coincidence mode, at the upper limit of the systems optimal performance, is 45 kc.s(-1) (kc=kilocounts) using the photopeak energy window only, and increases to 60 kc.s(-1) using the photopeak + Compton windows. Sensitivity results are compared with published data for a similar dual-head detector system.

Calibration↗

Determination of small objects from pinhole scintigrams.

This study assessed the possibility of measuring the linear dimensions of small structures using pinhole scintigraphy. A number of glass objects were made with a spherical, cylindrical or conical shape. Their maximum dimensions (diameters and heights) were 3.5-22.5 mm. These glass objects were filled with 131I, placed inside a plastic neck phantom and imaged using a gamma camera equipped with a pinhole collimator. The source-to-collimator distance was varied from 2 to 12 cm. An algorithm for image segmentation (threshold selection) was used to divide the image into object and background. On the segmented image, the number of non-zero pixels in the direction of the principal axes was multiplied by the appropriate calibration factor to obtain the linear dimensions of the object. Spatial resolution of the pinhole collimator, expressed as the full-width at half-maximum (FWHM), varied from 8 to 10 mm for the range of source-to-collimator distances examined. We found that, for dimensions up to 1.5 x FWHM, finite spatial resolution affects the accuracy of measurement. Non-linear correlation between true and calculated dimensions was used to take the latter into account. Our results are now being used to improve quantitation of remnant thyroid tissue masses for the calculation of radioiodine ablation doses.

Algorithms↗