PubMed Health⌕ Search

Biomedical subjects

D Groves

Publications and source records attributed to D Groves.

18 recordsLinked to original sources

Coronary artery bypass graft imaging using ECG-gated multislice computed tomography: comparison with catheter angiography.

AIM: To compare the value of multislice computerized tomography (MSCT) in imaging coronary artery bypass grafts (CABGs) by direct quantitative comparison with standard invasive angiography. METHODS: Using MSCT, 50 consecutive patients who had previously undergone CABG surgery and had recently undergone invasive angiography for recurrent angina pectoris, were studied further using MSCT after intravenous injection of non-ionic contrast agent; cardiac imaging was performed during a single breath-hold. Graft anatomy was quantified, using both quantitative coronary angiography (QCA) and MSCT, by different investigators blinded to each other. Reproducibility was quantified using the standard error of the measurement expressed as a percentage in log-transformed values (CV%) and intraclass correlation (ICC). RESULTS: All 150 grafts were imaged using MSCT; only 4 patent grafts were not imaged using selective angiography. Good agreement was achieved between MSCT and QCA on assessment of proximal anastomoses (CV% 25.2, ICC 0.84), mid-vessel luminal diameter (CV% 15.5, ICC 0.91) and aneurysmal dilations (CV% 14.3). Reasonable agreement was reached on assessment of distal anastomoses (CV% 26.7, ICC 0.66) and categorization of distal run-off (ICC 0.73). Good agreement was observed for stenoses of over 50% luminal loss (CV% 8.7, ICC 0.97) but agreement on assessment of less severe lesions was poor (CV% 208.7, ICC 0.51). CONCLUSION: This study demonstrates that CABGs can be quantitatively evaluated using MSCT, and that significant lesions present in all CABG segments can be reliably identified. Agreement between MSCT and QCA for lesions of less than 50% luminal loss was poor.

Aged↗

Health related quality of life of patients with refractory angina before and one year after enrolment onto a refractory angina program.

OBJECTIVE: This study was designed to assess the impact of a refractory angina programme on the health related quality of life for patients with chronic refractory angina (CRA) one year following enrolment. DESIGN: A one year prospective audit. SETTING: Specialist refractory angina clinic at a tertiary cardiac referral centre. PATIENTS: 69 consecutive refractory angina patients referred to a regional refractory angina centre from 1/03/2001 to 1/09/2002. INTERVENTIONS: Pain treatment algorithm in accordance with the recommendations of the national refractory angina guideline committee. MAIN OUTCOME MEASURES: Improvements in quality of life indices were assessed using Seattle angina questionnaire (SAQ), and short form-12 (SF-12) with changes in mood determined using the hospital anxiety and depression (HAD) questionnaire. RESULTS: All dimensions of the SF-12 and SAQ were superior at one year with significant improvement seen with the mental component of SF-12 (p = 0.023), and four of the five SAQ domains, angina stability (p = 0.028), angina frequency (p=0.02), treatment satisfaction (p=0.001) and quality of life (p < 0.001). All the significant changes within the SAQ domains were large enough to be considered clinically relevant. At one year the anxiety and depression domains were significantly improved from baseline (p = 0.015, 0.018) with clinical anxiety levels falling significantly from 55% to 40%, a relative reduction of 28% (p = 0.008). CONCLUSIONS: Implementation of the national refractory angina guidelines in a prospective study of 69 consecutive CRA patients significantly improved health related quality of life status at one year.

Aged↗

Effect of routine use of a multiplex PCR for detection of vanA- and vanB- mediated enterococcal resistance on accuracy, costs and earlier reporting.

A multiplex PCR (MPCR) for detection of vanA-and vanB-mediated resistance to vancomycin was optimized and adapted for use in the routine microbiology laboratory. Consecutive specimens (1196) submitted for vancomycin resistant Enterococci (VRE) surveillance were processed by clinical technologists on Bile Esculin Azide Agar containing 6 mg/L vancomycin (BEAA/Vanco6) plates and 466 showing black colony growth were processed by conventional biochemical testing (CBT) and by MPCR. CBT identified 208 VRE positives. MPCR detected 205 of the CBT- positives plus an additional 10. Analysis of the discordant specimens determined that 5 CBT- negative/MPCR-positive specimens also contained Enterococci with vanC resistance, 3 CBT-positive/MPCR-negative specimens were true positives, and 5 CBT-negative/MPCR-positive specimens occurred due to technical error. The sensitivity and specificity of MPCR were 98.4% and 96.1%. MPCR identifications of VRE were achieved approximately 48 h earlier than CBT and at 60% of the costs.

Bacterial Proteins↗

Direct detection of vanA and vanB genes in clinical specimens for rapid identification of vancomycin resistant enterococci (VRE) using multiplex PCR.

Surveillance for vancomycin resistant enterococci (VRE) by culture can be labour intensive and time consuming. We have developed a multiplex polymerase chain reaction (MPCR) which can be performed directly on the clinical specimen. The assay allows sensitive detection of enterococci with vanA - and vanB -mediated resistance to vancomycin. DNA was purified from stool and rectal specimens using the XTRAX(TM)DNA Extraction Kit (Gull Labs). Multiplex PCR amplified vanA and vanB targets were detected using a microtiter plate EIA. Two-hundred specimens were tested by routine culture and MPCR. Culture identified 44 VRE isolates and MPCR detected 38 of the 44 culture positives. Multiplex PCR detected three additional positive VRE specimens missed by culture for a sensitivity and specificity of 86.4 and 98.1%, respectively. When the presence of PCR inhibitors was addressed in the six culture positive/MPCR negative specimens, four additional VRE positive specimens were detected. Performing MPCR on the original specimens and on a 1:10 dilution of all specimens to minimize the effect of inhibitors gave a sensitivity and specificity of 95.5 and 98.1%, respectively. Multiplex PCR with confirmation by microtiter plate hybridization could be completed in 8 h compared with 24-48 h required for culture.

Bacterial Proteins↗

Vertical transmission of hepatitis C virus in New Zealand.

AIMS: To investigate the transmission of hepatitis C virus from viraemic mothers to infants. METHODS: The study group comprised 54 hepatitis C ribonucleic acid (RNA) positive, human immunodeficiency virus (HIV) negative women attending antenatal clinic, their infants when born, 12 previous children and 44 children of 29 additional nonpregnant, viraemic women. During the study period there were 60 live births (1 set of twins, 5 sequential pregnancies). All infants were tested at birth for hepatitis C virus (HCV) RNA. Thirty infants were retested at 6 months or later. Breast milk from 30 mothers was tested for HCV RNA. The 56 other children were tested for antibody to HCV and HCV RNA. RESULTS: Of the 60 infants tested at birth, 30 failed to attend a 6 month or later followup, 2 infants were HCV viraemic by six months of age, 2 infants had one episode of possible HCV RNA positivity followed by loss of detectable HCV RNA and 26 have shown no evidence of HCV infection. Five of the 30 breast milk samples tested were positive for HCV RNA. Four older children of viraemic mothers were HCV RNA positive. CONCLUSIONS: In this study, 2 of 30 (6.6%) of infants born to HIV negative, HCV viraemic mothers acquired HCV infection. Breast milk remains a possible contributory source of infant HCV infection. Management of babies born to HCV viraemic mothers should include retesting of baby for HCV RNA at 3 to 6 months of age.

Adult↗

The accuracy of clinical findings and laparoscopy in pelvic inflammatory disease.

The accuracy of clinical diagnosis for pelvic inflammatory disease was determined in 95 women who presented with pelvic pain to primary care physicians and then were referred to gynecologists. Laparoscopy or laparotomy with endometrial biopsy and fimbrial minibiopsy revealed that prevalence of pelvic inflammatory was 46% (44/95) and positive and negative predictive values of gynecologists were 74% (23/31) and 67% (43/64) (p = 0.0002). If histopathologic diagnosis was the standard, clinical accuracies of the gynecologists were no better than chance (p = 0.43), suggesting an expectation bias for visual diagnosis. Laparoscopy had a sensitivity of 50% (12/24) and a specificity of 80% (40/50) for salpingitis if the standard was fimbrial histopathologic diagnosis (p = 0.01). These results support the routine use of laparoscopy, supplemented when negative by endometrial and fimbrial minibiopsy, to accurately diagnose pelvic inflammatory disease.

Cervix Uteri↗

Gas-liquid chromatographic analysis of cellular fatty acids for identification of gram-negative anaerobic bacilli.

A commercially available, computer-assisted microbial identification system (MIS) employs gas-liquid chromatographic analysis of cellular fatty acids for bacterial identification. MIS was compared with conventional identification systems. Of 225 gram-negative anaerobes tested, MIS identified 72.4% of the strains to the species level, 88.9% to the appropriate group, and 93.3% to the correct genus.

Bacteriological Techniques↗

Accuracy and reproducibility of the MicroScan rapid anaerobe identification system with an automated reader.

Rapid anaerobe identification (MicroScan) panels (4 h) were evaluated both visually and by the AutoScan-4, a computer-controlled microplate reader. The results of both reading methods were compared with identifications obtained by the conventional (Virginia Polytechnic Institute) method. In total, 237 anaerobes were tested. Correct identifications were obtained for 166 strains (70%) by visual reading and 157 strains (66.2%) by the AutoScan-4. Supplementary tests resulted in 80.1 and 76.7% total correct identifications, respectively. Comparison of the two reading methods revealed complete agreement for 169 strains. Differences between the two reading methods were due to difficulties in reading specific reactions. This was especially true with the clostridial species. The performance of the MicroScan system in the identification of anaerobic bacteria appears comparable to that of other 4-h identification systems for anaerobes, but this system shows significant variance from the conventional system. Improvements in the trays and data base are required before the system can be recommended for routine use.

Autoanalysis↗

Comparison of RapID-ANA and Minitek with a conventional method for biochemical identification of anaerobes.

Two micromethods for the identification of anaerobes, one requiring growth (Minitek) and one nongrowth dependent (RapID-ANA), were compared with a conventional identification culture system. For 222 clinical isolates, RapID-ANA agreed with PRAS in 187 (84%) and Minitek agreed for only 170 strains (76%). Both systems identified common isolates well, but encountered some difficulty in identifying less common clostridia and Gram-negative bacilli. Although adequate for most strains, the results from both systems should be interpreted with caution, particularly for less frequently isolated species.

Bacteria, Anaerobic↗

Comparison of susceptibility results of anaerobic organisms determined by agar dilution method and Sceptor Anaerobe MIC/ID Micro Broth Dilution Panels.

A commercial broth microdilution system (Sceptor Anaerobe MIC/ID, BBL) for susceptibility testing of anaerobic bacteria was compared to a reference agar dilution system. Of the 172 organisms tested, only 7% failed to grow sufficiently for testing in the Sceptor system. In 1,590 antibiotic/organism combinations, 86.7% of the Sceptor results were identical or within one doubling dilution of the reference system. In 91.9% of the cases, interpretation of the results was same in both systems. Two hundred and twelve MIC values, however, differ by greater than or equal to 2 log2 dilution from the reference system. Due to this reduced correlation in the actual MIC values with the reference results, further studies are warranted before the Sceptor system can be recommended for routine use.

Agar↗

Adaptation of a coculture technique to the Minitek anaerobe system.

A method to produce anaerobic conditions by coculture with a nonfermentative organism was utilized in conjunction with the Minitek anaerobe system (BBL Microbiology Systems, Cockeysville, Md.) for identification of anaerobic bacteria from clinical specimens. With the coculture method, the Minitek anaerobe identification tests could be incubated under aerobic conditions. In 1,900 individual biochemical reactions, 1,826 (96%) were identical whether anaerobic conditions were achieved by conventional or coculture techniques. In comparison with the reference identification (Virginia Polytechnic Institute and State University, Blacksburg), both systems of incubation identified 91 of 99 strains (92%) correctly. The method of incubation had an effect on identification to the genus level in 1 of 99 (1%) strains and to the species level in 3 of 99 (3%) strains.

Bacteria, Anaerobic↗

Laser techniques for the evaluation of wear in Class II restorations.

A technique for the quantitative determination of the changes in surface topography of restorations during wear has been developed. This involves the optical contouring of the surface using a laser, and the generation of contour maps. Several different methods for interpreting these maps are discussed. A computer-aided method is the most consistently accurate and measures wear volume to an accuracy of 2--5%.

Computers↗

Screening urine with a leukocyte esterase strip and subsequent chlamydial testing of asymptomatic men attending primary care practitioners.

BACKGROUND AND OBJECTIVES: The detection of asymptomatic urethritis using a leukocyte esterase (LE) strip may have a role in primary care screening to select men who need diagnostic testing for Chlamydia trachomatis and Neisseria gonorrhoeae. STUDY DESIGN: Eight-hundred and eighty-two men, 16 to 35 years of age were studied when they attended their family physician or university health clinic for nongenitourinary complaints. First void urine (FVU) was tested by an LE strip (Chemstrip 2 LN, Boehringer Mannheim Corp., Indianapolis, IN), Chlamydiazyme (Abbott Laboratories, N. Chicago, IL) enzyme immunoassay with confirmatory blocking and polymerase chain reaction (PCR) with chlamydial plasmid primers. RESULTS: Forty-five men (5.1%) were positive (> trace) by LE strip. Of the LE-positive urines, 9 (20.0%) were positive by EIA or PCR, and none of the LE-negatives were positive by EIA or PCR. Twenty-three LE positives (5 EIA/PCR-positive; 1 PCR-positive; 17 EIA/PCR-negative) were able to be followed with a second urine and 2 urethral swabs. All of the 6 chlamydia-positives who had follow-up tests were positive by both immunoassay and PCR on urine. Based on the FVU results, the prevalence of asymptomatic chlamydial infection was 1.0% (9/88) (95% CL, 0.5 to 1.9) for which the LE urine strip was 100% (9/9) sensitive and 95.9% (837/873) specific. Analyses based on screening 1,000 men, 16 to 25 years of age, showed that the cost per case detected was $192.00 using the LE strip (> 1+) to select urine specimens for EIA testing, compared to $1,326.00 using the EIA to test all urine specimens. CONCLUSION: In this low prevalence, primary care setting, the LE urine strip was an accurate screening test, which if used to preselect urine specimens for subsequent chlamydial testing, would be less costly per case detected than assaying each specimen for chlamydia.

Adolescent↗