PubMed Health⌕ Search

Biomedical subjects

D H Lederer

Publications and source records attributed to D H Lederer.

6 recordsLinked to original sources

Which deep breathing device should the postoperative patient use?

A study was undertaken to compare the use of three types of deep-breathing devices in patients undergoing upper-abdominal operations. Seventy-nine patients were divided into three groups, each receiving preoperative bedside testing of pulmonary function and instruction in the use of one of three randomly assigned deep-breathing devices thought to be representative of those currently available (Triflo II, Bartlett-Edwards Incentive Spirometer, or Spirocare). Repeat testing and instruction were provided daily during each of the first five postoperative days. There were few statistically significant differences in pulmonary function, vital signs and white blood cell count, and no difference in length of postoperative stay. No device was uniformly acceptable to patients, and none was used as frequently as recommended. When left at the bedside and only one daily reinforcement of instructions, the three devices showed no clinically important differences.

Adult↗

Comparison of occlusion pressure and ventilatory responses.

The airway pressure 100 msec after the onset of an inspiratory effort against a closed airway (P100, occlusion pressure) is theoretically a more accurate index of respiratory neuron motor output than ventilation. Occlusion pressure and ventilation responses to hypercapnia were compared in repeated trials in 10 normal subjects while in the seated and supine positions. During progressive hypercapnia changes in P100 were also compared to changes in tidal volume and inspiratory airflow. These studies show that occlusion pressure increases linearly with hypercapnia in both sitting and supine subjects. Changing from the seated to the supine position, or vice versa, had no significant effect on either ventilation or occlusion pressure responses to CO2. Correlations between P100 and ventilation or airflow rate were significantly higher than correlations between P100 and tidal volume or breathing frequency. Intermittent random airway occlusion had no effect on either ventilation or pattern of breathing during hypercapnia. Occlusion pressure responses were no less variable than ventilation responses in groups of subjects whether studied seated or supine. However, maintenance of a constant moderate breathing frequency (20 breaths per minute) reduced the interindividual variability in ventilation and occlusion pressure responses to hypercapnia.

Adult↗