PubMed Health⌕ Search

Biomedical subjects

D H Sochart

Publications and source records attributed to D H Sochart.

At least 19 recordsLinked to original sources

Spontaneous vacuum phenomenon in the lateral compartment of the knee associated with a lateral tibial plateau fracture.

A case of spontaneous vacuum phenomenon in the lateral compartment of the knee is presented in an 83-year-old woman who attended the Accident and Emergency department two weeks after a twisting injury to the left knee. At the time of examination she still had a marked effusion in the knee with lateral joint line tenderness. X-rays showed a lateral tibial plateau fracture involving the entire lateral condyle and extending into the opposite compartment beneath the intercondylar eminence. The X-rays also demonstrated the presence of gas in the lateral joint line. This is the first reported case of vacuum phenomenon occurring on the same side as a lateral tibial plateau fracture. It is also demonstrated that the phenomenon may occur in the presence of an effusion.

Aged, 80 and over↗

Cross-match protocols for femoral neck fractures--finding one that can work.

BACKGROUND: Cross-match practice for patients with femoral neck fractures continues to cause concern due to a failure of compliance to the existing protocols. To address this issue, a number of studies were conducted over a 3-year period. METHODS: First, the existing cross-match practice for patients admitted with femoral neck fractures was reviewed to demonstrate the deficiencies within the system. Second, the opinion of anaesthetic and orthopaedic trainees was assessed regarding blood requirements for different femoral neck fractures following surgery and the justification of their perceptions. RESULTS: A summation of the studies is reported which demonstrates the reasons for the poor compliance to previous protocols. CONCLUSIONS: A simple and effective protocol is provided that has helped reduce pre-operative cross-matching of femoral neck fractures from 71% to 16.7% when assessed 2 years after its introduction.

Blood Grouping and Crossmatching↗

Evaluation of patient concerns before total knee and hip arthroplasty.

The preoperative concerns of patients undergoing total knee or hip arthroplasty were evaluated in a cross-sectional study of 370 patients. Patients completed a questionnaire on 29 concerns, each rated on a scale of 1 (not concerned) to 4 (very concerned). Short Form 12 and Oxford hip or knee scores were also calculated. The results showed that the greatest concern for patients was cancellation of the surgery. This was followed by failure of the surgery to reduce pain, loss of a limb, and joint infection. Concerns regarding scar problems, nursing care, and preoperative tests were the lowest. Women showed statistically significant greater concerns in 9 areas. Younger patients (age, <65) showed increased concerns in 8 areas. Patients who had previously undergone joint arthroplasty were less concerned than those who had not undergone previous lower limb joint arthroplasty for 6 responses. They showed increased concern in 2 areas, nursing care and hospital food. Those undergoing total hip arthroplasty were more concerned about dislocation, dressing, and returning to work (all, P<.05). This study provides useful information for the preoperative counseling of patients and the production of preoperative literature.

Adult↗

Expect the best, prepare for the worst: surgeon and patient expectation of the outcome of primary total hip and knee replacement.

A cross-sectional study of 100 surgeons and 370 patients awaiting primary total hip or knee replacement was carried out. Oxford hip or knee score questionnaires were sent to the surgeons and patients. They were asked to predict the level of symptoms expected 6 months following surgery. The Oxford scores derive a value of 12-60, with a greater score indicating worsening symptoms. The mean pre-operative score was 45.12 for the hip patients and 42.96 for the knee patients, and the patients expected this to drop to 23.70 and 25.66, respectively, 6 months' postoperatively. This was a significant difference for both groups. The surgeons expected the patients to have a mean postoperative score of 20.91 for the hip group and 22.19 for the knee group. The surgeons' scores were significantly lower than those from the patients. There was a significant difference between the patients' and surgeons' expectations of the results of total knee and hip replacement surgery. The surgeons expected better results than the patients. We believe that this is the first study that directly compares surgeon and patient expectations of lower limb arthroplasty.

Adult↗

Charnley low-friction arthroplasty for Paget's disease of the hip.

This study investigated the perceived risks and complications associated with total hip arthroplasty for Paget's disease. A total of 98 Charnley low-friction arthroplasties were performed on 76 patients, 27 men (37 hips) and 49 women (61 hips), whose average age was 67.4 years (range, 51-79 years). Intraoperative blood loss averaged 388 mL (range, 110-1,730 mL), and minor heterotopic ossification occurred in 24 hips (25%), with significant changes in 4 hips (4%). After average follow-up of 10.4 years (range, 5.5-20 years), 10 acetabular (10%) and 8 femoral (8%) implants had loosened aseptically, but there was no evidence of progressive protrusio acetabuli or femoral deformity after operation. Survivorship to revision was 98% at 10 years (95% confidence interval [CI], 95%-100%) and 91% at 15 years (95% CI, 80%-100%) for the acetabular component and 93% (95% CI, 87%-99%) and 89% (95% CI, 80%-99%) for the femur. The only increased risk identified was nonunion of the trochanteric osteotomy (13%).

Aged↗

Biaxial wrist replacement. Initial results in the rheumatoid patient.

We report a short term review of 26 patients after Biaxial total wrist replacement. The mean follow up was 33.6 months (range, 24-62). All except one patient with psoriatic arthropathy had either seropositive or negative rheumatoid arthritis. A significant improvement in the range of motion was obtained; however, only 14 of 26 achieved a "functional" range. Eighteen obtained an excellent or good result when graded using the Hospital for Special Surgery score. Two radial and three carpal components showed radiolucent lines. Follow-up, however, was too short to determine whether this indicates progressive loosening.

Activities of Daily Living↗

The relationship of foot and ankle movements to venous return in the lower limb.

We have studied the relationship between movements of the foot and ankle and venous blood flow from the lower limb using colourflow Duplex ultrasound to determine the optimum type of exercise for promoting venous return. Studies of both active and passive movements were carried out on 40 limbs in 20 subjects (18 men; 2 women), with a median age of 27 years (20 to 54). We assessed ankle dorsiflexion and plantar flexion, subtalar inversion and eversion, and a combination of all movements. There was no difference in venous flow when comparing opposite limbs in a single subject (p > 0.5), but active exercises produced higher peak and mean velocities of blood flow than passive ones. The active combined movement produced the highest velocities with an increase of 38% in mean and of 58% in peak flow velocities, which were significantly greater than the peak and mean flow rates produced by passive movements. The active combined exercise would therefore be the most effective in eliminating stasis and could contribute to the prevention of deep-vein thrombosis.

Adult↗

Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty.

Polyethylene wear and the subsequent development of periprosthetic osteolysis are the major factors limiting the longevity of total hip arthroplasties. A minority eventually loosen, but no clinically applicable system exists for accurate early prediction of failure. The relationship between acetabular wear and the development of loosening, osteolysis, and revision was investigated in 235 Charnley low friction arthroplasties. The average age of the patient at surgery was 31.7 years (range, 17-39 years), and the duration of followup averaged 234 months (19.5 years; range, 74-364 months). Total wear averaged 2.1 mm (range, 0-7.2 mm), and the average wear rate was 0.11 mm per year (range, 0-0.55 mm/year), with the wear rate of revised components being twice that of surviving ones (0.19 mm/year versus 0.09 mm/year). The prevalence of osteolysis (33 hips, 14%) and of acetabular and femoral component loosening and revision rose significantly with increasing wear. Osteolysis also was associated significantly with femoral component loosening and revision, but the presence of calcar changes was not (90 hips, 38%). Twenty-five year survivorship exceeded 90% for arthroplasties with a wear rate less than 0.1 mm per year, but 20-year survivorship of acetabular components with a rate greater than 0.2 mm per year was below 30%, and none survived 25 years. For every additional millimeter of wear, the risk of acetabular revision in any one year increased by 45% and for the femur increased by 32%.

Adolescent↗

Poor results following internal fixation of displaced subcapital femoral fractures: complacency in fracture reduction.

The results following internal fixation of displaced subcapital femoral fractures are poorer than for undisplaced fractures and are determined by both the quality of the initial reduction and the accuracy of implant placement. In a series of 26 consecutive displaced fractures internally fixed with Richards hip pins, satisfactory reduction was achieved in only 15 hips. Accurate reduction is a prerequisite for correct screw placement and occurred in only 4 of the 11 poorly aligned fractures, as opposed to 11 of the 15 well reduced ones. A total of 10 hips required a further surgical procedure as the result of complications. These results highlight the importance of accurate fracture reduction in facilitating implant placement as well as the importance of good surgical technique rather than reliance purely upon the implant. These already common fractures are assuming increasing socioeconomic importance as the elderly population grows, and successful management is vital for both the individual patient and future demands on the health service.

Adult↗

Failure of the spiral blade module of the AO unreamed femoral nail.

The treatment of subtrochanteric femoral fractures remains difficult despite the introduction of modern intramedullary nailing techniques. Accurate fracture reduction, correct siting of the proximal entry point and restoration of medial support remain essential for a successful outcome. We report a case of failure of the spiral blade module of the AO unreamed femoral nail, which may have been precipitated by incorrect siting of the entry point, resulting in poor implant positioning within the femoral head.

Accidental Falls↗

Long-term results of cemented Charnley low-friction arthroplasty in patients aged less than 30 years.

The results of cemented Charnley low-friction arthroplasty in patients aged less than 30 years are presented. Eighty-three arthroplasties were performed on 55 patients with an average age of 24.9 years (range, 17-29 years) and an average follow-up period of 240 months (20 years; range, 62-360 months). There were 2 nonfatal pulmonary emboli, 2 cases of deep sepsis, and 3 fractured femoral implants. Twenty-eight acetabular components migrated (34%), 25 have been revised (30%), and the average annual acetabular wear rate was 0.12 mm. Sixteen femoral implants subsided (19%), and fracture of the tip of the cement mantle occurred in 8 hips (10%). Nineteen femoral components (23%) were revised; femoral osteolysis was seen in 15 hips (18%) and changes in the calcar in 33 (38%). Acetabular component survivorship was 92% (95% confidence interval, 85-98%) at 10 years, 70% (60-81%) at 20 years, and 68% (57-79%) at 25 years, with the figures for the femoral implant being 93% (87-98%), 76% (66-86%), and 73% (62-85%), respectively.

Adolescent↗

Comparison of the Wrightington FC hip with the Charnley low-friction arthroplasty. 10- to 15-year results and survival analysis.

Between 1981 and 1986 two groups of patients received either Charnley low-friction arthroplasties or the Wrightington Frusto-Conical hip replacement with otherwise identical management before and after operation. There were 260 consecutive replacements in 215 patients in the first group and 260 consecutive procedures in 211 patients in the second. Both components of each design were cemented and featured a 22.25 mm femoral head, but the geometry of the stems differed. Of the patients lost to follow-up, 16 (18 hips) were in the Wrightington series and 24 (36 hips) in the Charnley series, and of those who have died 20 (23 hips) were Wrightington and 14 (16 hips) were Charnley. All surviving patients have been followed up clinically and radiologically or until revision was necessary. The mean length of follow-up for original surviving components in both series was 140 months (120 to 180). Pain, function and movement were measured by the grading system of Merle D'Aubigné and Postel and showed a marked improvement in both groups. There was little or no pain in 98% of patients in the Wrightington series and 96% in the Charnley series, while 93% and 85%, respectively, were entirely painfree. Trochanteric osteotomy was used in 292 cases overall, with a complication rate of 13% due to wire breakage, trochanteric bursitis or trochanteric detachment, requiring a further operation in 5.8% (17 hips). Heterotopic ossification was seen in 40% of cases in which trochanteric osteotomy had been performed (117 hips) but only 3% (10 hips) had clinically significant changes. After the direct lateral approach heterotopic ossification was seen in 24% (42 hips) with only 2% in class 3 or 4 (4 hips). Femoral osteolysis was more common in the Charnley series, occurring in 7.6% of cases (17 hips) as opposed to 2.1% (5 hips) in the Wrightington series. Ten acetabular and seven femoral components have been revised in the Wrightington series and 16 acetabular and 11 femoral implants in the Charnley series. Survivorship based on revision for aseptic loosening using the Kaplan-Meier technique showed survival of the femoral implant at 5, 10 and 15 years of 100%, 99% and 98%, respectively in the Wrightington and 100%, 99% and 87% in the Charnley series. The survival of the acetabular component at 10, 12 and 15 years respectively, was 100%, 99% and 95% for the Wrightington, and 99%, 98% and 84% for the Charnley. The survival of both the acetabular and femoral components of the Wrightington system at a mean of 11.7 years was better than that of the Charnley system, with a lower incidence of radiological loosening of unrevised components.

Acetabulum↗