PubMed Health⌕ Search

Biomedical subjects

D Hammel

Publications and source records attributed to D Hammel.

At least 37 records · Page 2Linked to original sources

Successful cardiac transplantation after Novacor implantation in a HIT II-patient using heparin.

The anticoagulative management of patients tested positive for heparin-induced thrombocytopenia type II (HIT II) and requiring cardiac surgery has been difficult until now. A special challenge arises, when left ventricular assist devices have to be implanted for bridging to cardiac transplantation. We report on the anticoagulative management of such a patient, based on the consideration of HIT II-pathophysiology and using heparin for Novacor LVAD implantation and cardiac transplantation.

Adult↗

Wound complications after left ventricular assist device implantation.

BACKGROUND: Wound necrosis and infection pose a tremendous risk for patients with left ventricular assist devices. METHODS: We analyzed our database of patients with left ventricular assist devices for those who developed wound dehiscence and concomitant infection after left ventricular assist device implantation. RESULTS: Three of our 66 patients (4.5%) with implantable ventricular assist devices had had severe wound complications with necrosis of the abdominal or thoracic wall uncovering part of the device. The predominant impact on the development of these complications was presumably related to multiple surgical interventions on the same site. CONCLUSIONS: Nevertheless, these patients can recover and undergo successful heart transplantation if adequately managed.

Abdominal Muscles↗

Preoperative immunoglobulin treatment in patients with Werlhof's disease undergoing cardiac operation.

BACKGROUND: Patients with Werlhof's disease and undergoing a cardiac surgical procedure with cardiopulmonary bypass are at increased risk for bleeding complications. We report the usefulness of preoperative immunoglobulin treatment in selected patients. METHODS: Between May 1995 and July 1998, 10 patients with Werlhof's disease underwent a cardiac surgical procedure with cardiopulmonary bypass in our department. Five patients with mean platelet counts of less than 80x10(9)/L received immunoglobulin therapy preoperatively (group 1). The other 5 patients with mean platelet counts higher than 80x10(9)/L were not so treated (group 2). RESULTS: In group 1, mean platelet count increased from 54x10(9)/L 5 days before operation to 112x10(9)/L after immunoglobulin treatment (p = 0.018) and did not fall to less than 60x10(9)/L postoperatively. Patients in group 1 received 16 units of packed red blood cells and 5 units of platelet concentrate. Patients in group 2 required 24 units of packed red blood cells, 5 units of platelet concentrate, and 23 units of fresh frozen plasma. Only 1 patient (group 2) had a surgical bleeding complication that required reexploration. Mean drainage loss was 1,100 mL in group 1 and 1,210 mL in group 2. CONCLUSIONS: Our data demonstrate that immunoglobulin treatment of patients with Werlhof's disease and mean platelet counts of less than 80x10(9)/L significantly augments platelet counts preoperatively. It may be useful in selected patients.

Adult↗

Anticoagulative management of patients requiring left ventricular assist device implantation and suffering from heparin-induced thrombocytopenia type II.

BACKGROUND: Heparin-induced thrombocytopenia type II (HIT II) is a rare but life-threatening side effect of heparin therapy. We describe the perioperative anticoagulative management of patients tested positive for HIT II and requiring implantation of a left ventricular assist device (LVAD). METHODS: We report on 3 patients with a different perioperative anticoagulative management (preoperative, intraoperative, and postoperative anticoagulation with danaparoid-sodium; preoperative anticoagulation with recombinant hirudin, anticoagulation with danaparoid-sodium intraoperatively and postoperatively; preoperative anticoagulation with recombinant hirudin, intraoperative anticoagulation with heparin, and postoperative anticoagulation with danaparoid-sodium) and discuss the difficulties of the treatment. RESULTS: Anticoagulation with alternative drugs such as recombinant hirudin and danaparoid-sodium led to serious and life-threatening bleeding complications as well as to thromboembolic events in the first 2 patients. Therefore the third patient underwent LVAD implantation using heparin for intraoperative anticoagulation to avoid administration of high doses of recombinant hirudin or danaparoid-sodium. Despite very low anti-factor Xa activities, when using danaparoid-sodium postoperatively, the patient suffered from a bleeding complication on the 4th day after LVAD implantation requiring reexploration. CONCLUSIONS: In selected cases (negative heparin-induced platelet aggregation (HIPA) test at the time of LVAD implantation and continuation of postoperative anticoagulation with recombinant hirudin or danaparoid-sodium), heparin may be used for LVAD implantation in HIT II patients to reduce bleeding complications.

Adult↗

Surgical management of extensive lipomatous hypertrophy of the right atrium.

Lipomatous hypertrophy of the right atrium is a rare lesion that is usually limited to the interatrial septum. The authors report on a patient that suffered from an extensive lipomatous hypertrophy, which protruded into the right and left atrium as well as the superior vena cava and caused inflow obstruction. Therapeutic management is discussed.

Cardiomegaly↗

Effect of high dose platelet inhibitor treatment on thromboembolism in Novacor patients.

BACKGROUND: Thromboembolism and bleeding are among the most hazardous complications following implantation of long-term left ventricular support systems. This report focuses on the effect of high dose platelet inhibitor treatment in patients with the Novacor system to prevent thromboembolic events. METHODS: Thirty-eight (out of 58) Novacor patients (43+/-11 years old) were studied in a non-randomized manner. Postimplantation: 20 patients were treated with heparin only (control group), whereas in the other 18 patients aspirin (3x330 mg/day) and dipyridamol (3x75 mg/day) were added to the treatment protocol (aspirin group). RESULTS: Age, body size, underlying heart disease and support interval were comparable among both groups, however, patients in the aspirin group were much sicker with regard to urgency status, postoperative right heart failure and hematologic disorders. Cerebral thromboembolic complications were lower in the aspirin group (33% of patients, 0.4+/-0.7 events) as compared to the control group (55% (P=0.18), 1.4+/-2.3 events (P=0. 048)). Non-cerebral thromboembolism of surgical relevance was rare. The incidence of bleeding complications was mildly increased in the aspirin group. CONCLUSION: The addition of high dose platelet inhibitors seems to lower the incidence of thromboembolism in Novacor patients.

Adult↗

Selection and management of ventricular assist device patients: the Muenster experience.

BACKGROUND: Because of the growing discrepancy between the availability of donor organs and the number of patients with end-stage heart disease who need heart transplantation, a larger proportion of patients waiting for a suitable donor heart require pre-operative mechanical circulatory assistance. The criteria for the selection and management of these patients as applied at Muenster University Hospital are reviewed. METHODS: The study population consists of 631 patients referred to our center for transplantation between January 1, 1990, and December 31, 1996. Two hundred ninety-seven patients were listed for transplantation and 157 were transplanted. Of 41 patients who underwent implantation of a ventricular assist device (n = 34, Novacor; n = 6, TCI HeartMate; n = 1, Medos), 39 received the device as a bridge to transplantation and 2 as permanent support. For the purpose of the analysis, the study population was divided into 3 groups (elective bridging, urgent bridging, emergency bridging) and compared with heart transplant candidates who did not require mechanical circulatory assistance. RESULTS: Patients who underwent elective or urgent assist-device implantation were younger and had greater hemodynamic compromise than the remainder of patients waiting for heart transplantation, as suggested by a higher functional class and lower mean arterial pressure, cardiac index, serum sodium, and pulmonary artery wedge pressure. Survival of patients who electively underwent implantation of an assist device was better than that of patients who were stable on the waiting list and did not undergo heart transplantation during follow-up. CONCLUSIONS: This finding suggests that earlier implantation of assist devices may facilitate resolution of organ dysfunction before heart transplantation.

Adult↗

Fractally coated defibrillation electrodes: is an improvement in defibrillation threshold possible?

AIMS: In patients with implantable cardioverter-defibrillators (ICD), the goals of lowering the defibrillation threshold (DFT) can be achieved by means of higher defibrillation safety margins, more rapid charging of capacitors, improved battery longevity, implying smaller devices. Whether an increase in the electrically active surface of ICD leads by fractal coating results in decreased DFTs is unknown. METHODS AND RESULTS: In this prospective randomized cross-over study the defibrillation efficacy of a novel right ventricular endocardial defibrillation electrode fractally coated with iridium was compared with an uncoated but otherwise identical electrode in 30 patients undergoing ICD implantation. In each patient, DFT testing was performed twice according to a binary search protocol introducing the two different electrodes in a random order. The mean DFT was 8.4 +/- 4.1 J with the fractally coated lead and 9.6 +/- 3.6 J using the uncoated lead. The improvement of 1.2 J was statistically not significant (P = 0.11). No differences were observed between the patients with an improved DFT (n =12) and those with an unchanged or worsened DFT (n = 18) concerning age, underlying cardiac disease, NYHA class, or left ventricular ejection fraction, respectively. CONCLUSION: Increasing the electrical surface of defibrillation leads by fractal coating does not lead to a substantial clinically relevant reduction in defibrillation thresholds. Defibrillation impedance is not influenced by the increased electrical surface of the defibrillation lead.

Adult↗

Mesenteric blood flow during cardiopulmonary bypass in pigs.

BACKGROUND: Gastrointestinal complications represent a serious problem after cardiopulmonary bypass. Hypoperfusion of the gastrointestinal tract during bypass has been implicated as the cause. We therefore investigated blood flow in the superior mesenteric artery during cardiopulmonary bypass. METHODS: Mature female pigs (n = 12) were investigated. While six sham-operated animals served as control (group I), six pigs underwent normothermic cardiopulmonary bypass for 180 minutes (group II). Bypass flow was 2.4 l/m2/minute. Standard regimens for anesthesia and cardiopulmonary bypass were used. Blood flow in the superior mesenteric artery was assessed by Doppler flowmetry. RESULTS: Blood flow in the superior mesenteric artery did not change significantly in group I. In group II, mesenteric blood flow increased significantly from baseline at 120, 150, and 180 minutes. Oxygen consumption in the mesenteric circulation increased significantly in group II at 90 and 180 minutes compared to baseline, as well as oxygen extraction. Lactate content in the mesenteric vein in group II increased compared to control at 30, 90 and 180 minutes. CONCLUSION: Overall gastrointestinal blood flow is not impaired during cardiopulmonary bypass in this animal model. Instead, gastrointestinal blood flow increased during normothermic cardiopulmonary bypass as well as oxygen consumption.

Animals↗

Ambulatory care of patients with left ventricular assist devices.

BACKGROUND: Left ventricular assist devices (LVAD) have revolutionized the treatment of patients with acute and chronic heart failure as they provide a high quality of life. We report on our experience with patients receiving ambulatory care after LVAD implantation. METHODS AND RESULTS: Since July 1995, 46 patients with a mean age of 45+/-11 years underwent implantation of an electrically driven LVAD with portable controller and batteries. Sixteen (35%) patients bridged >30 days were treated in part on an outpatient basis. After LVAD implantation, they were treated in the hospital for 86+/-32 days (range 40 to 153 days). Afterward, they received ambulatory care for 74+/-76 days (range 2 to 301 days, total experience 1206 days). In 13 cases, the outpatient treatment was interrupted by 1.7+/-1.7 readmissions, for a total of 32+/-42 days (median 19 days). Reasons for readmission included systemic or drive line infections (incidence 0.0066 per outpatient day), suspected or true thromboembolic events (incidence 0.0066 per outpatient day), and suspected malfunction of the LVAD. One patient supported as alternative to transplantation died after cerebral bleeding after 244 days, 1 patient with a history of acute myocarditis had ventricular fibrillation during LVAD assist while being at home for 177 days and died in a low output state, 10 patients were given transplantation after a mean support interval of 206+/-88 days, and 4 patients currently await heart transplantation. CONCLUSIONS: Outpatient treatment after LVAD implantation is feasible, and severe complications are uncommon.

Adult↗

Combining nonpharmacologic therapies for advanced heart failure: the Münster experience with the assist device-defibrillator combination.

Implantable cardioverter defibrillators (ICDs) and ventricular assist devices (VADs) have been used as a bridge to cardiac transplantation. In selected patients, the combined implantation may be required. This study was motivated by a case of a 33-year-old female patient with giant cell myocarditis who died of ventricular tachyarrhythmias after having been placed on a VAD with which she had been treated on an out-of-hospital basis for a prolonged period of time. A subsequent retrospective analysis of our data showed that, of 73 patients who had to be bridged mechanically (54 Novacor, 12 TCI Heartmate, 4 Thoratec, 3 Medos) in our institution between 1993 and 1998, 10 patients had undergone defibrillator implantation either before (n = 8) or after (n = 2) implantation of a VAD. The cases are presented, and the feasibility of the combination therapy discussed.

Adult↗

Overexpression of tissue-type plasminogen activator in atherosclerotic human coronary arteries.

UNLABELLED: The plasminogen activator (PA)/plasmin system is involved in various pathological processes that are considered important features of atherogenesis and atherothrombosis. These include the proteolysis of fibrin deposits and extracellular matrix components as well as the induction of cell migration and mitogenesis. Tissue-type PA (TPA) is a key enzyme mediating plasminogen to plasmin conversion. TPA plasma concentrations are elevated in patients with advanced atherosclerosis and correlate with an increased risk for myocardial infarction and stroke. In this study, we have analysed the content and expression of TPA in human coronary arteries and their relation to the presence and severity of atherosclerotic lesions. METHODS: Segments of coronary arteries obtained from heart explants (n = 15) were classified by the presence and types of atherosclerotic lesions. TPA was quantitatively determined in protein extracts of intimal and medial layers. In situ hybridization and immunohistochemical analyses were performed on serial sections of representative tissue specimens. RESULTS: PA activity entirely attributable to the presence of active TPA was consistently detected in the protein extracts. Extractable TPA antigen and activity showed a significant graded increase in relation to the presence and severity of atherosclerotic lesions. The ratios of active over total TPA were increased several-fold in extracts of advanced lesions despite a concomitant threefold increase in TPA complexed to its inhibitor PA-1. In macroscopically normal arterial segments and in early lesions, TPA was expressed in the endothelium and in colocalization with vascular smooth muscle cells (VSMCs). In advanced plaques, TPA mRNA was mainly detected in the lateral regions of the fibrous caps in association with migrating VSMCs and in the vicinity of the core areas infiltrated by CD68-positive macrophages. CONCLUSIONS: TPA content and expression is consistently increased in relation to the severity of the lesions in atherosclerotic coronary arteries. This may contribute to plaque destabilization and disruption. Conversely, the increased intramural TPA activity may counteract mural fibrin deposition.

Arteries↗

Minimally-invasive versus conventional aortic valve replacement--perioperative course and mid-term results.

OBJECTIVE: We performed a case-control-study to compare perioperative and mid-term results of minimally invasive with conventional aortic valve replacement. METHODS: Between 8/96 and 7/97, 113 patients underwent isolated aortic valve replacement (minimally invasive: 29, conventional: 84) in our Department. Diagnosis, ejection fraction, pressure gradient/regurgitation fraction, age, gender and body-mass-index were used as matching criteria for the case-control-study. For qualitative data correspondence was requested, for quantitative data deviations up to 10% were accepted. With these criteria 25 patients of the minimally invasive group were matched to 25 patients of conventional group. All patients were reexplored 1 year after aortic valve replacement. Statistical analysis was done by the Fisher's exact test for qualitative data and the Mann-Whitney test for quantitative data. RESULTS: We implanted 15 (20) bioprosthesis' and 10 (five) mechanical prosthesis' in the minimally invasive, respectively, conventional group. There were no statistically significant differences between both groups with respect to the perioperative course, only duration of surgery (mean 201.6 vs. 143.9 min, P < 0.01) and extracorporeal circulation (mean 116.1 vs. 71.3 min, P < 0.01) as well as aortic-cross-clamp-time (mean 77.9 vs. 46.9 min, P < 0.01) were significantly longer in the minimally invasive group. Postoperative complications occurred in one patient of the minimally invasive group (dissection of the right coronary artery) and four patients of the conventional group (third degree AV block, pneumothorax, grand mal convulsion, cardiopulmonary resuscitation). Two patients, one of each group, died during follow-up for unknown reasons. Follow-up revealed no significant differences with respect to clinical and echocardiographic data, but the shorter skin incision was cosmetically more accepted by patients of the minimally invasive group. Minor paravalvular leaks occurred in four patients of the minimally invasive and three patients of the conventional group as diagnosed by transthoracic echocardiography. CONCLUSIONS: Both surgical techniques may be performed with comparable perioperative and mid-term results, but the better cosmetic result in the minimally invasive group is paid by a longer duration of surgery.

Adult↗

A simple new model of physiologically working heterotopic rat heart transplantation provides hemodynamic performance equivalent to that of an orthotopic heart.

BACKGROUND: The widely used non-volume-loaded abdominal heterotopic heart transplant (NL) in rats undergoes atrophy after transplantation. Various techniques have been designed to load the transplanted heart because of its potential immunological impact. Our aim was to create a volume-loaded heterotopic heart transplantation model (VL) capable of ejection and practical for routine studies. Using this model, we tested the hypothesis that VL isografts would retain myocardial performance comparable to native hearts (NH). METHODS: Heterotopic hearts were transplanted using and end-to-side anastomosis between the donor's superior vena cava and the recipient's abdominal inferior vena cava. The right ventricle loads the left ventricle (LV) via a direct anastomosis of the pulmonary artery to the left atrium. The LV ejects volume through an end-to-side anastomosis of the donor's aorta to the recipient's abdominal aorta. Hemodynamic data (systolic and diastolic LV pressures, dP/dt max and min, tau) were studied in-situ (at baseline and after adding volume) and in a Langendorff perfusion system (at baseline and after stimulation with isoproterenol) 2 weeks after transplantation. RESULTS: In situ systolic pressure and diastolic function of VL was superior to NL, and beta-adrenergic stimulated performance in the Langendorff perfusion of VL showed hemodynamic performance equivalent to NH, unlike NL which had a diminished response. CONCLUSION: This technique results in a volume-loaded ejecting heart transplant model that preserves anatomical structures. The VL can be evaluated in situ and after explantation in Langendorff perfusion system and may offer advantages if workload of the graft is of significance to the study performed.

Abdomen↗

Multiple hardware complications in a patient with an ICD.

Hardware-related complications in implantable cardioverter/defibrillators (ICD) are still a common problem. Identifying underlying reasons becomes more and more difficult as the complexity of ICD systems increases. We report a patient with a dual chamber ICD (DDD-ICD) who suffered multiple complications. These included: ventricular oversensing causing inappropriate shocks and episodes of asystole; an insulation defect resulting in ineffective shocks as a consequence of a short circuit between the active can device and a defective high voltage cable; and device dysfunction requiring several hospitalizations and operative system revisions.

Aged↗

Effective gene transfer in the rat myocardium via adenovirus vectors using a coronary recirculation model.

BACKGROUND: Gene therapy promises to play an important role in the treatment of heart disease and in transplantation. The limited effectiveness of gene transfer, however, remains an unresolved problem. The aim of the study was to create a model for more effective gene transfer using adenovirus vectors carrying the lacZ-reporter gene (AdV-lacZ). METHODS: Beating Lewis rat hearts perfused with oxygenated Krebs-Henseleit solution were harvested, after which an atrial septal defect (ASD) was created. All vessels were tied and AdV-lacZ was injected into the aortic root. The solution was recirculated through the ASD to the left side of the heart and pumped back to the coronary arteries by the left ventricle. Incubation was allowed for 20 min at 15 degrees C and the hearts were subsequently transplanted heterotopically in syngeneic rats. This method was compared to AdV-lacZ injection into cardioplegic hearts. The hearts were harvested after 2, 7, or 14 days and evaluated histologically for expression of the lacZ gene. RESULTS: Maximal gene expression was achieved after 7 days by the recirculation model. There was less efficient gene expression at day 2 and at day 14. No evidence of ischemic injury of the myocardium was noticed histologically. Almost no successful gene expression was seen in the arrested hearts. CONCLUSION: This novel recirculation method lets the vector be repeatedly exposed to the endothelium, resulting in an effective gene expression after 7 days incubation time rather than after 14, when a decline has set in presumably due to immunologic response.

Adenoviridae↗