Radiation exposure in bone mineral density assessment.

Osteoporosis is a systematic skeletal disease characterized by low bone mass and microarchitectural deterioration of bone tissue which leads to diminished biomechanical competence of the skeleton and low-trauma or atraumatic fractures. Due to increased awareness of the impact of osteoporosis on the elderly population, the use of bone densitometric techniques is becoming more widespread. Considerable progress has been made in the development of non-invasive methods for the assessment of the skeleton. While DXA and QCT are commonly used techniques, the popularity of other approaches such as RA, SXA and QUS is gaining grounds. QCT has an advantage over the other techniques in its ability to measure the true volumetric density of trabecular or cortical bone. We therefore present an overview of these current techniques for bone mineral density (BMD) measurements. In the second section we discuss the radiation doses incurred in BMD measurements by patients and methods for reducing patient and staff radiation exposure are given. Studies of radiation dose to patient from DXA confirms that patient dose is small (0.08-4.6 muSv) compared to that given by many other investigations involving ionizing radiation. Fan beam technology with increased resolution has resulted in increase patient dose radiation dose (6.7-31 muSv) but this is still relatively small. Carrying vertebral morphometry using DXA also incurs less radiation dose (< 60 muSv) than standard lateral radiographs QCT has radiation dose (25-360 muSv) comparable to simple radiological examination such as chest X-ray but lower than imaging CT. Radiation dose from other techniques such as RA and SXA are in the same order of magnitude as pencil beam DXA. For pencil beam DXA and SXA systems the time average dose to staff from scatter is very low even with the operator sitting as close as 1 m from the patient during measurement. However the scatter dose from fan beam DXA systems is considerable higher and approaches limits set by regulator bodies for occupational exposure.

Absorptiometry, Photon↗

An in vitro investigation of the dependence on sample thickness of the speed of sound along the specimen.

To measure the speed of sound (SOS), most quantitative ultrasound (QUS) devices use the transmission mode, whereby two transducers are placed on opposite sides of the sample. This mode is limited to a few specific skeletal sites because of the varying configuration of bone geometry and varying amounts of overlying soft tissue at most other sites. The aim of this study was to address the dependence of SOS measured along the sample on the thickness and composition of the bone sample. Bovine samples from mid-femur and trochanter, and perspex phantoms were used. We prepared the perspex samples in the shapes of blocks and cylinders to investigate the effect of wall thickness on SOS. The thickness of the blocks was decreased in decrements of 1 mm; a 22 mm diameter hole was drilled through the cylindrical samples and the hole size was gradually increased. The second configuration was also used with the bovine samples. For each experimental set-up five SOS measurements were acquired, with the probe aligned along the sample and a mean value computed. All measurements were taken with castor oil as the coupling agent, and in the cylindrical cases, the oil was used to fill the tube. The measurement precision determined as the root mean square coefficient of variation (RMSCV) was determined to be 0.14% and 0.65% for perspex and bovine samples respectively. The measured SOS on the perspex phantom (2760+/-4 m/s) was within the published values for bulk velocity. It was observed that for both perspex and bovine samples the SOS was independent of sample wall thickness greater than the wavelength (2.2 mm, 2.7 mm and 3.5 mm for perspex, trochanter and mid-femur respectively). The SOS decreased with sample wall thickness smaller than the wavelength in concordance with theoretical predictions. The SOS values obtained for bovine samples reflected either totally cortical (mid-femur) or a composite of cortical and cancellous bone (trochanter).

Animals↗

An evaluation of a new gel-coupled ultrasound device for the quantitative assessment of bone.

Quantitative ultrasound (QUS) is now being accepted as a tool in the assessment of bone status. Most QUS devices measure broadband ultrasound attenuation (BUA) and speed of sound (SOS). A newly introduced device, the Acoustic Osteo-Screener (AOS-100), measures both SOS and an attenuation related parameter called the transmission index (TI) and provides a derived parameter called osteo sono-assessment index (OSI). The purpose of this study was to examine the reproducibility of this new device, compare the results with the UBA 575+ and evaluate the effect of using two platforms to compensate for different foot sizes on the measured values. 83 subjects aged 21-89 years, who gave informed consent, were recruited. Subjects were assigned to three different groups determined by age and health status. The short-term measurement precision (expressed as root mean square coefficient of variation) of SOS (0.13-0.16%) and TI (1.18-1.96%) was similar to and better than that obtained for the UBA 575+. Significant negative correlations were found between the differences in SOS measured with the two platforms (adaptors to adjust the position of the foot relative to the foot plate) and foot length (p < 0.0001). This implies that small feet are more influenced by the differences of measured location. All QUS parameters measured with the small platform were found to be significantly smaller than those with the large platform (p < 0.0001). The mean percentage differences were 0.6% in SOS, 2.8% in TI and 4.3% in OSI with the large foot platform giving larger value results. Proper use of the platforms resulted in more reproducible SOS and TI. This study demonstrated that the newly developed AOS-100 parameters TI and OSI were highly reproducible. This study also demonstrated that the use of an inappropriate platform can cause discrepancies in QUS readings and poor reproducibility.

Adult↗

Does combining the results from multiple bone sites measured by a new quantitative ultrasound device improve discrimination of hip fracture?

There is a growing interest in the use of quantitative ultrasound (QUS) measurements as an alternative to current radiation-based bone densitometry techniques for the noninvasive assessment of fracture risk. While most of the commercialized ultrasound devices measure only single predefined peripheral skeletal sites, the Omnisense prototype (Sunlight Ltd., Israel) can be used on multiple bones, including the spinous processes. In this study, we examined the ability of speed of sound measured at the calcaneus, distal third and ultradistal radius, proximal third phalanx, metacarpal, capitate, patella, and the posterior process of the thoracic spine to differentiate subjects with hip fractures from normal controls. Seventy-nine postmenopausal Caucasian Israeli women who had sustained an atraumatic fracture of the proximal femur within the last 6 months were recruited from the local population (mean age 80 +/- 8.9 years). As controls, 295 postmenopausal Caucasian Israeli women without osteoporotic fractures were also included (mean age 70 +/- 8.7 years). Discrimination of hip fractures with QUS at all ultrasound sites was highly statistically significant (p < 0.01) (odds ratios [ORs] = 1.4-3.0; area under the ROC curve [AUC] 77-92%), except for the hand metacarpal. Distal radius and calcaneus measurements (ORs = 2.4 and 3.0) were the best discriminators of hip fracture patients from controls. Using a forward selective linear regression model, the discriminator values of combined assessment at two sites were investigated. There was moderate improvement in diagnostic value, but the best combination was the calcaneus with the distal radius, which improved the AUC by 3% and raised both the sensitivity and specificity to 94%. These data demonstrate the encouraging potential of improving discrimination of hip fracture by using multiple-site ultrasonic measurements.

Aged↗

Factors influencing the speed of sound through the proximal phalanges.

The amplitude-dependent speed of sound (AD-SOS) in the proximal phalanges is reported to be sensitive to osteoporotic changes. We investigated the influence of bone thickness and cortical thickness on AD-SOS. Phantoms made of Perspex were designed to simulate different bone width (11-16 mm) and cortical thickness (3-7.5 mm). The phantoms were designed with two opposing flat and cylindrical surfaces. The effect of cortical thickness was examined by drilling holes (simulating the medullary canal) of different diameters (1-7 mm) in the middle of the Perspex cylinders. The effect of sample thickness was investigated on solid Perspex phantoms of varied lengths. The standardized precision errors of AD-SOS measurement in vivo and in vitro on volunteers and phantoms were 2.8 and 0.9%, respectively. AD-SOS was influenced by the bone width, cortical thickness, and location along the phalanx. A decrease in either cortical width or cortical thickness resulted in a decrease in AD-SOS. The effect is dependent on whether the contact surface is curved or flat. It is possible that a curved surface has a focusing effect on the wave through the porous core, whereas for a flat surface, the path of the waves might not pass through the center. When cortical thickness and bone width were expressed as a ratio, there was a linear relationship between this ratio and AD-SOS through the phantoms. AD-SOS was independent of thickness for samples greater than 11 mm.

Adult↗

How hip and whole-body bone mineral density predict hip fracture in elderly women: the EPIDOS Prospective Study.

We conducted a population-based cohort study in 7598 white healthy women, aged 75 years and over, recruited from the voting lists. We measured at baseline bone mineral density (BMD g/cm2) of the proximal femur (neck, trochanter and Ward's triangle) and the whole body, as well as fat and lean body mass, by dual-energy X-ray absorptiometry (DXA). One hundred and fifty-four women underwent a hip fracture during an average 2 years follow-up. Each standard deviation decrease in BMD increased the risk of hip fracture adjusted for age, weight and centre by 1.9 (95% CL 1.5, 2.3) for the femoral neck, 2.6 times (2.0, 3.3) for the trochanter, 1.8 times (1.4, 2.2) for Ward's triangle, 1.6 times (1.2, 2.0) for the whole body, and 1.3 times (1.0, 1.5) for the fat mass. The areas under the receiver operating characteristic (ROC) curves were not significantly different between trochanter and femoral neck BMD, whereas ROC curves of femoral neck and trochanter BMD were significantly better than those for Ward's triangle and whole-body BMD. Women who sustained an intertrochanteric fracture were older (84 +/- 4.5 years) than women who had a cervical fracture (81 +/- 4.5 years) and trochanter BMD seemed to be a stronger predictor of intertrochanteric ([RR = 4.5 (3.1, 6.5)] than cervical fractures ([RR = 1.8 (1.5, 2.3]). In very elderly women aged 80 years and more, hip BMD was still a significant predictor of hip fracture but the relative risk was significantly lower than in women younger than 80 years. In the 48% of women who had a femoral neck BMD T-score less than -2.5, the relative risk of hip fracture was increased by 3, and the unadjusted incidence of hip fracture was 16.4 per 1000 woman-years compared with 1.1 in the population with a femoral neck BMD T-score > or = -1.

Absorptiometry, Photon↗

Hyperthyroidism influences ultrasound bone measurement on the Os calcis.

The objective of our study was to compare bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DXA) and quantitative ultrasound (QUS) parameters in women with hyperthyroidism and controls. In this cross-sectional study, QUS parameters and BMD values observed in untreated hyperthyroid patients were compared with data obtained from age-matched controls. Twenty-four women with Graves' disease were studied. Eight patients were postmenopausal. All patients had evidence of thyrotoxicosis as indicated by a raised total serum thyroxine and a suppressed serum thyroid stimulating hormone. BMD of the hip, lumbar spine and whole body, and body composition, were measured by DXA. Ultrasound evaluation on the os calcis was performed with an Achilles device. All measurements were performed before antithyroid therapy. The QUS parameters of BUA, SOS and Stiffness were significantly lower in hyperthyroid patients than in controls. Similar results were observed for the BMD of lumbar spine, femoral neck and total skeleton. Lean tissue and fat mass were also significantly decreased in hyperthyroid patients. In conclusion, these findings suggest that hyperthyroidism affects cortical and trabecular bone equally, as well as bone quality. QUS measurements may be helpful for assessing, using a simple and non-irradiating method, the bone effects of thyrotoxicosis.

Absorptiometry, Photon↗

Do markers of bone resorption add to bone mineral density and ultrasonographic heel measurement for the prediction of hip fracture in elderly women? The EPIDOS prospective study.

We have previously shown that hip bone mineral density (BMD), heel broadband ultrasound attenuation (BUA) and bone resorption markers are independent predictors of hip fracture in elderly women. We investigated whether a combination of these three parameters could improve the predictive value of a single test in a nested case-control analysis (75 hip fractures and 228 age-matched controls) of the EPIDOS prospective study comprising 7598 healthy women 75 years of age and older followed prospectively for a mean 22 months. At baseline, prior fracture, femoral neck BMD by dual-energy X-ray absorptiometry (DXA), heel BUA and urinary type I collagen C-telopeptide breakdown products (CTX) were assessed. The area under the receiver operating characteristic curve was significant for the three diagnostic tests, heel BUA being the best single predictor. The added value of urinary CTX to either BMD or BUA depends on the cutoff point chosen to define patients at risk and on the therapeutic strategy that is considered. Defining patients at risk as those with low BMD (or low BUA) or high CTX resulted in a significant increase in the sensitivity compared with BMD or BUA alone--a strategy that could be applied when a broad treatment is considered. However, this increased sensitivity was also obtained simply by increasing the BMD and BUA cutoffs, suggesting that a combination of CTX with BMD/BUA is not useful for that type of treatment strategy. Conversely, defining patients at risk as those with both low BMD and high CTX increases the specificity (88% vs 78%) with a similar number of hip fracture patients being identified (30% vs 32%)--a combination that could be useful when the strategy is to target treatment to a subset of high-risk patients. This strategy appears to be more cost-effective than bone mass measurement alone as indicated by the 37% fewer patients who need to be treated to avoid one fracture per year. If DXA or ultrasound is not available, the combination of a bone resorption marker with a history of any type of fracture after the age of 50 years gave a predictive value similar to that obtained with femoral neck BMD or heel BUA alone, for both types of treatment strategy. We conclude that the combination of urinary CTX with hip BMD could be useful for the identification of elderly women at high risk for hip fracture, resulting in higher specificity for a given sensitivity threshold than BMD measurement alone. If DXA is not available, the combination of history of fracture and urinary CTX performs as well as hip BMD to assess hip fracture risk in elderly women.

Aged↗

Ultrasound characterization of bone demineralization.

Quantitative ultrasound (QUS) assessment of bone may permit an assessment of bone properties currently not available by bone densitometry techniques. To explore the effects of the quantity of bone mineral on acoustic parameters, we carried out an in vitro study of the impact of demineralization on attenuation of ultrasound in trabecular bone. Ten fresh cubes of trabecular bone obtained from bovine distal femurs were progressively demineralized using formic acid solution. The progression of demineralization was controlled by monitoring the specimen bone mineral density (BMD) using dual x-ray absorptiometry (DXA). At five stages of demineralization-0% (baseline), 25%, 50%, 75%, and 100% (all mineral removed)-the US properties of the specimens were assessed (Walker Sonix UBA 575+). The US parameters investigated were broadband ultrasound attenuation (BUA) and ultrasound attenuation in bone (UAB). Both DXA and QUS measurements were made along the three orthogonal axes of each cube. Our results demonstrated significant variability in both BUA and UAB along the three principle axes of the cubes whereas BMD did not differ in the different directions. A strong but nonlinear correlation was found between BMD and US attenuation. A reduction in BMD to 50% of the baseline values resulted in BUA (UAB) reduction to 25% and 19%, respectively. A random effect model analysis supported a multiplicative relationship between BMD and the US parameters. US attenuation is a sensitive indicator of bone mineral changes with nonlinear dependence on bone mineral loss. Bone collagen structure reinforced by hydroxyapatite crystal accounts for fundamental US characteristics. Ultrasound attenuation associated with trabecular orientation is basically dominated by the mineral spread in a collagen framework.

Absorptiometry, Photon↗

The use of quantitative ultrasound to monitor fracture healing: a feasibility study using phantoms.

Fracture healing has traditionally been monitored subjectively using manual manipulation of the fracture site and evaluation of radiographic images. A more objective method of monitoring would provide obvious advantages, allowing healing progress to be quantitatively assessed and so providing the opportunity for early detection of problems. A tibia phantom was used to investigate whether the longitudinal propagation velocity of ultrasound across a fracture site could be used quantitatively to assess fracture healing. The characteristic of fracture healing simulated by the phantom was the changing gap between the bone ends at the fracture site. The ultrasound velocity was measured using a recently developed machine, the SoundScan 2000 (Myriad Ultrasound Systems Ltd, Israel). The precision of the SoundScan 2000 was found to be 0.4% in vitro. Ultrasound velocity predicted the simulated fracture gap with a high degree of accuracy (R2 = 0.994). The measured and the theoretically calculated velocity for different widths between the simulated bone ends was found to be highly correlated with a coefficient of determination of 0.998. This result shows that the use of quantitative ultrasound to monitor fracture healing warrants further investigation in vivo.

Equipment Design↗

Influence of human obesity on the metabolic fate of dietary long- and medium-chain triacylglycerols.

The metabolic fate of an oral long-chain-triacylglycerol (LCT) load and of a mixed oral LCT and medium-chain-triacylglycerol (MCT) load was followed for 6 h in eight control and eight obese subjects with normal postabsorptive triacylglycerol concentrations. Labeled triacylglycerol and indirect calorimetry were used. Results showed that LCTs were less oxidized in obese than in control subjects (3.2+/-0.5 compared with 6.0+/-0.4 g, P < 0.01). Moreover, the amount of LCT oxidized was negatively correlated with fat mass (r = -0.77, P < 0.01). Appearance in plasma of dietary triacyglycerol-derived long-chain fatty acids was blunted in obese subjects and it was negatively related to fat mass (r = -0.84, P < 0.01) and positively to LCT oxidation (r = 0.70, P < 0.01). On the contrary, MCT oxidation was not altered in obese subjects compared with control subjects. Furthermore, the proportion of MCTs oxidized was higher in both groups compared with LCTs (x+/-SEM: 57.5+/-2.6% compared with 15.2+/-1.6%, P < 0.01, n = 16). Our conclusion is that obesity is associated with a defect in the oxidation of dietary LCTs probably related to an excessive uptake by the adipose tissue of meal-derived long-chain fatty acids. MCTs, the oxidation of which is not altered in obesity, could therefore be of interest in the dietary treatment of obesity.

3-Hydroxybutyric Acid↗

Peripheral measurement techniques for the assessment of osteoporosis.

Peripheral measurement techniques have been the first to be developed for the assessment of osteoporosis, and they remain useful. Besides traditional approaches such as radiographic absorptiometry (RA), radiogrammetry, and single-photon absorptiometry (SPA), new peripheral approaches have been developed that offer powerful ways to assess skeletal status in osteoporosis. These include single x-ray absorptiometry (SXA), peripheral dual x-ray absorptiometry (pDXA), peripheral quantitative computed tomography (pQCT), quantitative ultrasound (QUS) techniques, and magnetic resonance imaging (MRI) approaches. This review describes the current role of peripheral imaging techniques vis-à-vis their central imaging counterparts. Peripheral measurement techniques are attractive because equipment cost is substantially lower, radiation exposure is small, and the devices require less space and sometimes are even portable. Additionally, QUS and MRI offer the potential to measure aspects of bone status beyond the limits of bone densitometry. Peripheral techniques represent important diagnostic methods for the assessment of osteoporosis.

Absorptiometry, Photon↗

How can we measure bone quality?

Osteoporosis is a systematic skeletal disease characterized by low bone mass and microarchitectural deterioration of bone tissue. This leads to diminished biomechanical competence of the skeleton and is associated with low-trauma or atraumatic fractures. In the past decade, considerable progress has been made in the development of methods for assessing the skeleton non-invasively, so that osteoporosis can be better managed. While dual X-ray absorptiometry (DXA) is still the preferred methodology, several limitations will be addressed. Another densitometric technique which is widely accepted for diagnosis of spinal osteoporosis is single energy QCT. Measurements of vertebral trabecular bone mineral density (BMD) demonstrate larger percentage decrements between vertebrally-fractured subjects and normal controls, and confer higher relative risks for vertebral fracture than either anteroposterior or lateral DXA measurements. As an emerging alternative to photon absorptiometry techniques, there is a growing interest in the use of quantitative ultrasound (QUS) measurements for the non-invasive assessment of osteoporotic fracture risk in the management of osteoporosis. The attractiveness of QUS lies in the fact that indirect and in vitro experience has suggested that ultrasound may give information not only about BMD but also about architecture and elasticity. Whether or not combining QUS and DXA improve fracture prediction is still unclear and needs further analysis. Due to the growing evidence supporting the use of QUS in osteoporosis and the large number of QUS devices already on the market, a general clinical consensus on the application of QUS is urgently needed. Other techniques that are less widely used for the management of osteoporosis. For example, peripheral quantitative computed tomography, quantitative magnetic resonance (QMR) and magnetic resonance microscopy are promising tools for the evaluation of the skeleton. For example, the ability of QMR and high resolution magnetic resonance imaging has been explored and shows promise as a technique for assessing trabecular bone structure in osteoporosis.

Absorptiometry, Photon↗

The effects of density and test conditions on measured compression and shear strength of cancellous bone from the lumbar vertebrae of ewes.

An animal model (the ewe) was used to study mechanical parameters of cancellous bone specimens. Compression and shear tests were conducted on ewe vertebral trabecular bone (L1-L5) from old ewes (mean age: 9 years) under two different conditions: first, at room temperature in air ("standard" test conditions); and secondly, in a physiological saline bath regulated at 37 degrees C. The parameters obtained under "standard" test conditions with a uniaxial compression test were the mean value of the maximum strength (sigma max = 22.3 (7.06) MPa), Young's modulus (E = 1510 (784) MPa), the strain at maximum strength (epsilon sigma max = 3.21 (0.8) percent) and the energy absorbed during the test (W = 0.3 (0.12) MJ.m-3). No significant change was found when the test was carried out in a saline bath at 37 degrees C (p < 0.0005). An original shear test was performed to evaluate the shear strength which was found to vary from 7.5 (4.7) to 14.6 (8.53) MPa under "standard" test conditions depending on the method of calculation. Testing of the specimens in a 37 degrees C physiological saline bath induced a decrease in the shear strength from 32.5 percent (p < 0.0005) to 37.3 percent (p < 0.0001) of those measured under "standard" test conditions. The non-destructive measurement of the Bone Mineral Density (BMD) accounted for up to 73.3 percent of the maximum compressive strength sigma max and 61.5 percent of the maximum shear strength tau max determined in saline solution at 37 degrees C. These results showed that other parameters influencing the mechanical properties of trabecular bone and its structure appeared to be essential.

Absorptiometry, Photon↗

Different morphometric and densitometric parameters predict cervical and trochanteric hip fracture: the EPIDOS Study.

We used an experimental software measuring the hip axis length (HAL) and bone mineral density (BMD) in specific regions of the lower and upper part of the femoral neck on dual-energy X-ray absorptiometry scans. To determine whether these parameters were significant predictors of the type of hip fracture, we measured 167 healthy women (controls), 24 women with trochanteric, and 42 women with cervical hip fractures within the EPIDOS prospective cohort. EPIDOS is a multicenter prospective study on risk factors for hip fracture performed in 7575 elderly women living at home, aged 75-95 and conducted in five French centers (Amiens, Lyon, Montpellier, Paris, Toulouse). Measurements were performed on data acquired at baseline before the occurrence of fracture. In the cervical fracture group, HAL was significantly longer than in controls (94.2 vs. 92.3, p = 0.03), and the associated odds ratio (OR) adjusted for age, weight, and total femoral neck BMD was significant (OR = 1.64, 95% confidence interval [CI] 1.06-2.55). In contrast, HAL was not significantly different from controls in the trochanteric fracture group. Femoral neck diameter was not a predictor of fracture. The upper and lower femoral neck BMD was lower in the trochanteric fracture group than in controls, and both measurements predicted trochanteric femoral neck fracture. In contrast, the prediction of cervical femoral neck fracture was enhanced by measuring only the upper part of the femoral neck (OR = 2.79 vs. 1.97 for the total femoral neck) while BMD of the lower part was not different from controls. Hip axis length is a predictor of femoral neck fracture. Femoral neck BMD distribution is different between cervical and trochanteric fractures. These results support the hypothesis of a different pathophysiological mechanism between the two types of hip fractures.

Absorptiometry, Photon↗

Effects of a new positioner on the precision of hip bone mineral density measurements.

In an attempt to reduce patient positioning errors, the authors tested the use of a new hip-specific positioning tool, OsteoDyne's Hip Positioner System (HPS). The HPS is an "A" frame splint designed to abduct both legs approximately 15 degrees to hold them in full extension at the hips and knees and to lock the feet in a neutral position. Seventy volunteer women aged 35-82 years were randomly assigned in two age-matched groups (mean age 56 years). Each group underwent two consecutive femur dual X-ray absorptiometry (DXA) scans with intermediate repositioning using the HPS system and two others utilizing the standard hip positioner provided with Hologic and Lunar scanners. One technician performed all scans using a Hologic QDR 1000-Plus and Lunar DPX-Plus densitometer. One hundred and fifty volunteer women aged 50-84 years (mean age, 64 years) were recruited in a multicenter study for the assessment of precision. Each subject underwent three consecutive femur DXA scans with intermediate repositioning using the HPS system. The coefficient of variation (CV) was significantly improved at the femoral neck by the use of the HPS with 0.7 versus 1.2 with the Hologic densitometer but only moderately altered at other sites. Similar results were found with the Lunar densitometer with improvement of precision at the femoral neck, 0.8 versus 1.8 with a similar trend but no significant difference at the other regions. No statistical difference was noted between the femoral neck BMD measured with the HPS system and with the standard positioners in either group. The mean precision of data obtained on the QDR 1000+ was 0.8% (range 0.1-1.4) for the femoral neck BMD, 1.1% (range 0.1-3.0) for the trochanter BMD, 2.3% (range 0.2-5.2) for Ward's triangle BMD, and 0.8% (range 0.1-1.9) for the total femur BMD. The mean precision of data obtained on the QDR 2000 was 0.7% (range 0.1-2), 1% (range 0.1-4.9), 2.6% (range 0.3-5.7), and 0.7% (range 0.1-1.8), respectively. In conclusion, data obtained with the new OsteoDyne's HPS seem capable of reducing patient positioning errors for the hip measurement. Its use is likely to improve confidence in hip bone mineral density measurements.

Absorptiometry, Photon↗