PubMed Health⌕ Search

Biomedical subjects

D Herring

Publications and source records attributed to D Herring.

6 recordsLinked to original sources

Unilateral iliac vein occlusion, caused by bladder enlargement, simulating deep venous thrombosis.

A variety of conditions cause unilateral leg swelling and thus mimic deep venous thrombosis (DVT). A heretofore-underappreciated condition that may lead to unilateral iliac vein compression, simulating DVT, is massive enlargement of the bladder caused by urinary retention. A case that demonstrates this condition is described. Although this disorder has been reported only three times before, its occurrence should be recognized by clinicians in light of the overall aging of our society. In addition, this case highlights the need for careful and thorough evaluation of patients who have unilateral lower-extremity edema.

Aged↗

Bedside technology: seven keys to success.

Bedside technology offers a unique opportunity to enhance patient care and improve labor resource utilization. Achieving success with bedside technology in this environment is a difficult proposition with considerable risk. Based on the experience of the authors, there are seven keys to success which reduce the risk and drive the long-term usefulness of bedside technology.

Decision Making, Organizational↗

New rehabilitation concepts in management of radical neck dissection syndrome. A clinical report.

The purposes of this article are to define radical neck syndrome and to present a new concept of using range-of-motion exercises combined with isokinetic muscle loading rehabilitation to provide the patient with a functional and pain-free shoulder. Each part of the rehabilitation program, including an exercise program that the patient continues at home, is explained in detail.

Exercise Therapy↗

Evaluation of the clinical management of cancer patients. A pilot study.

The Johns Hopkins Oncology Center, Baltimore, has carried out a pilot study of a method of data collection and analysis to be used for planning and evaluation of continuing education programs conducted in the Maryland region. This study includes definition of techniques used to prepare a test instrument that will accurately reflect actual medical practice within a hospital. The system has been field tested in three diseases, cancer of the lung, breast, and uterine cervix, in two Maryland hospitals. The system appears to be an efficient and inexpensive method for definition of decision making in specific clinical settings and for measurement of change if serial reassessment is instituted.

Breast Neoplasms↗

The effect on syringe performance of fluid storage and repeated use: implications for syringe pumps.

Syringe stiction has been reported to cause syringe pump malfunction, hence the effect on syringe performance of syringe use and the formulations used in the syringe were investigated. The force required for syringe plunger motion (at 2.5 mm min-1), when filled with soybean oil emulsion (SBOE) and with water, and the extraction of silicone oil from syringes by these fluids, were measured for Primo, Talus and Terumo 10 mL, and Terumo 50 mL syringes. The breakloose, average extrusion and maximum force required to maintain plunger motion increased after storage of SBOE for 7 days in all syringes tested (p < 0.05). The storage of water increased the breakloose force of all syringes, but only increased the maximum force of Talus syringes, and both the average extrusion and maximum forces of Terumo 10 mL syringes. The mechanism for this is most likely swelling of the elastomer of the piston due to sorption of fluid. The force was found to increase logarithmically with repeated syringe use. Electrothermal atomization atomic absorption spectroscopy was used to measure the silicone oil content of syringe extractions. Three extractions were performed: repeated flushing, vigorous washing, and storage for 7 days with occasional agitation. Up to 69.4% of the silicone oil present in the syringes was extracted with both water and SBOE when they were stored or washed. In contrast to water, SBOE also extracted the lubricant when the syringe was filled and flushed immediately. If syringes are refilled, stored filled before use, or used over a prolonged period, particularly with a SBOE formulation, syringe striction may occur during infusion with a syringe pump.

Drug Storage↗