PubMed Health⌕ Search

Biomedical subjects

D Isaacson

Publications and source records attributed to D Isaacson.

At least 37 records · Page 2Linked to original sources

Detection and imaging of electric conductivity and permittivity at low frequency.

This paper is concerned with low frequency electrical impedance imaging, which is the process of constructing images of the electrical impedance of a body's interior based upon measurements of voltage and current made at the body's surface. The electrical impedance accounts for both resistivity and permittivity. This paper shows how permittivity can be exploited to improve the performance of an electrical impedance imaging system. We show that explicit use of the independent information in the data due to the permittivity will ehance a system's ability to distinguish objects in the interior of a body. In addition, we report the results of experiments performed using the Rensselaer ACT 2 system on a saline bath containing various objects. These objects include both living tissue and metal conductors with oxide layers. We demonstrate the system's ability to distinguish these objects, and we exhibit gray scale images of both their resistivity and permittivity distributions.

Diagnostic Imaging↗

In-vivo evaluation of ofloxacin in Salmonella typhimurium infection in mice.

The effects of ofloxacin in Salmonella typhimurium infection in mice were compared with those of ciprofloxacin, ampicillin and chloramphenicol. Oral administration of ofloxacin at 10, 50 or 100 mg/kg once per day for seven days significantly (P less than 0.02) increased survival (20.1 days at 100 mg/kg) of infected mice relative to non-treated controls (4.1 days). In addition, after oral treatment with 100 mg/kg of each of the antibiotics, ofloxacin was significantly more effective than ampicillin (9.9 days), chloramphenicol (8.4 days) or ciprofloxacin (14.9 days) in prolonging the mean survival time of these mice. A comparison of oral potencies indicates that ofloxacin is five times more potent than ciprofloxacin (oral ED50 = 13.3 mg/kg vs ciprofloxacin = 69.9 mg/kg) and over eight times more potent than either of the other two antibiotics. When the number of bacteria from livers and spleens was quantitated, only ofloxacin (25 or 100 mg/kg,po) significantly (P less than 0.02) reduced the number of viable bacteria in both of these tissues in comparison with untreated controls, and, relative to the other antibiotics, ofloxacin (100 mg/kg) caused a significantly greater reduction. Single oral dosing of 20 mg/kg of either ofloxacin or ciprofloxacin showed that ofloxacin achieves approximately a four-fold higher peak serum or liver concentration than ciprofloxacin, which may contribute to its better efficacy in this infection model. These results taken together suggest that oral ofloxacin may be of value in treating systemic salmonella infections in humans.

Ampicillin↗

Errors due to measuring voltage on current-carrying electrodes in electric current computed tomography.

Electric current computed tomography is a process for determining the distribution of electrical conductivity inside a body based upon measurements of voltage or current made at the body's surface. Most such systems use different electrodes for the application of current and the measurement of voltage. This paper shows that when a multiplicity of electrodes are attached to a body's surface, the voltage data are most sensitive to changes in resistivity in the body's interior when voltages are measured from all electrodes, including those carrying current. This assertion is true despite the presence of significant levels of skin impedance at the electrodes. This conclusion is supported both theoretically and by experiment. Data were first taken using all electrodes for current and voltage. Then current was applied only at a pair of electrodes, with voltages measured on all other electrodes. We then constructed the second data set by calculation from the first. Targets could be detected with better signal-to-noise ratio by using the reconstructed data than by using the directly measured voltages on noncurrent-carrying electrodes. Images made from voltage data using only noncurrent-carrying electrodes had higher noise levels and were less able to accurately locate targets. We conclude that in multiple electrode systems for electric current computed tomography, current should be applied and voltage should be measured from all available electrodes.

Algorithms↗

Rapid assessment of electrode characteristics for impedance imaging.

Electrical impedance imaging is the technique for producing images of the resistivity of internal body structures based on measurements of voltage and current from electrodes applied to the body's surface. When a multiplicity of electrodes are applied in one or more rows around a body structure such as the thorax or limb, it is useful to be able to rapidly assess the general status of the electrode-body interface to determine if the skin has been suitably prepared, and that electrode and skin impedance are suitably low. In addition, assessment of the impedance of individual electrodes should precede acquisition of data for image formation. This communication presents techniques for assessing the overall skin and electrode impedances relative to the impedance of the body interior, and for assessing the integrity of each electrode's contact impedance.

Diagnostic Imaging↗

Electrode models for electric current computed tomography.

This paper develops a mathematical model for the physical properties of electrodes suitable for use in electric current computed tomography (ECCT). The model includes the effects of discretization, shunt, and contact impedance. The complete model was validated by experiment. Bath resistivities of 284.0, 139.7, 62.3, 29.5 omega.cm were studied. Values of "effective" contact impedance zeta used in the numerical approximations were 58.0, 35.0, 15.0, and 7.5 omega.cm2, respectively. Agreement between the calculated and experimentally measured values was excellent throughout the range of bath conductivities studied. It is desirable in electrical impedance imaging systems to model the observed voltages to the same precision as they are measured in order to be able to make the highest resolution reconstructions of the internal conductivity that the measurement precision allows. The complete electrode model, which includes the effects of discretization of the current pattern, the shunt effect due to the highly conductive electrode material, and the effect of an "effective" contact impedance, allows calculation of the voltages due to any current pattern applied to a homogeneous resistivity field.

Computer Simulation↗

Theory and performance of an adaptive current tomography system.

It has been shown that there exists an optimum set of current patterns for distinguishing one conductivity distribution from another. Since the optimum set of current patterns depends on the conductivity distribution being imaged it must be determined for each object being imaged. This paper describes how these current patterns may be determined and describes a system for achieving this in practice.

Electricity↗

Current topics in impedance imaging.

We introduce a definition of 'best' currents to apply to an electrode array on the surface of a body in order to distinguish between the conductivity inside the body and a conjectured conductivity. Using these 'best' currents, we illustrate with a simple example the general fact that a single current applied between a pair of electrodes, loses its ability to distinguish between different conductivities as the size of the region over which the current is applied goes to zero. We next introduce approximations to the best currents on systems having L electrodes, and calculate the ability of these systems to distinguish between conductivities as L goes to infinity and the electrode size goes to zero. We conclude with a simple example that illustrates a process for producing the 'best' currents without a previous knowledge of what is inside the body.

Electric Conductivity↗

Summertime actinic lichenoid eruption (lichen planus actinicus).

A patient with an unusual lichenoid photosensitive eruption is presented. The features differentiating this entity from classic lichen planus, lupus erythematosus, and polymorphous light eruption are discussed. Phototesting confirmed the provocative influence of sunlight. We prefer the name "summertime actinic lichenoid eruption" to that of "lichen planus subtropicus" or "lichen planus actinicus," since this condition is not confined to subtropical countries, and, although light appears to initiate the eruption, its exact relationship to lichen planus is unclear.

Adult↗

Localized vulvar syringomas.

Syringomas are benign appendageal tumors with differentiation toward the intraepidermal portion of the eccrine sweat duct. A 35-year-old black woman with lesions confined to the labia majora is presented. Syringomas involving the genitalia are rare, and usually the genital tumors are part of a more generalized distribution. A review of English literature showed only four reported cases of syringomas limited to the vulva. Vulvular syringomas present as multiple, bilateral, skin-colored papules over the labia majora that may or may not be pruritic. The lesions should therefore be considered in the differential diagnosis of multiple papular lesions of the vulva and are probably more common than is generally recognized.

Adenoma↗

Preface.

Explore the source record for details and available documents.

Dental Restoration, Permanent↗

Biologic contours.

Explore the source record for details and available documents.

Dental Restoration, Permanent↗