PubMed Health⌕ Search

Biomedical subjects

D J De Franco

Publications and source records attributed to D J De Franco.

3 recordsLinked to original sources

Mandibular shape and skeletal divergency.

Pre-treatment lateral cephalograms of 41 skeletal Class I girls aged 11 to 15 were divided according to MP-SN angle: lower than 28 degrees (hypodivergent, 10 girls), between 31 and 34 degrees (normodivergent, 18 girls), or larger than 37 degrees (hyperdivergent, 13 girls). The mandibular outlines were traced and digitized, and differences in shape were quantified using the elliptic Fourier series. Size differences were measured from the areas enclosed by the mandibular outlines. Shape differences were assessed by calculating a morphological distance (MD) between the size-independent mean mathematical reconstructions of the mandibular outlines of the three divergency classes. Mandibular shape was different in the three classes: large variations were found in hyperdivergent girls versus normodivergent girls (MD = 4.61), while smaller differences were observed in hypodivergent girls (MD versus normodivergent 2.91). Mean size-independent mandibular shapes were superimposed on an axis passing through the centres of gravity of the condyle and of the chin. Normodivergent and hyperdivergent mandibles differed mostly at gonion, the coronoid process, sigmoid notch, alveolar process, posterior border of the ramus, and along the mandibular plane. A significant size effect was also found, with smaller mandibles in the hyperdivergent girls.

Adolescent↗

Frictional resistances using Teflon-coated ligatures with various bracket-archwire combinations.

Static frictional resistances were compared between Teflon-coated stainless steel and clear elastomeric ligatures used with various combinations of brackets and archwires. Stainless steel metal, polycrystalline ceramic and single crystal ceramic 0.022-inch slot brackets were used in combination with stainless steel and nickel titanium archwires, 0.018 inch and 0.016 x 0.022 inch. Friction was measured in the dry state at bracket-archwire angulations of 0, 5, 10, and 15 degrees. Moments induced by engagement of the archwires into the brackets were measured for each archwire type and bracket-archwire angulation. Teflon-coated ligatures produced less friction than elastomers for all bracket-archwire combinations. The ceramic brackets generally elicited greater frictional resistances than stainless steel brackets. Regarding both friction and control of tooth movement, these data suggest that sliding mechanics are best executed with stainless steel brackets and stainless steel archwires. Moreover, these data reveal the usefulness of Teflon-coated ligatures in minimizing the high friction of ceramic brackets when an esthetic appliance is imperative.

Aluminum Oxide↗