Device nonuse among adult cochlear implant recipients.

OBJECTIVE: To examine the causes and prevalence of previous and current device nonuse among adults who have received cochlear implants. STUDY DESIGN: Retrospective case review. SETTING: Adult tertiary referral center for cochlear implantation. METHODS: Two hundred fourteen consecutively implanted adult patients. The length of implant use ranged from 1 month to 14 years. MAIN OUTCOME MEASURE: A period of 4 consecutive weeks of nonuse of cochlear implant, including both obligatory and elective nonuse. RESULTS: Twenty-nine adults (13.6% of implantees) were identified as having at some stage not used their device for a period of more than 4 consecutive weeks. The main reason was device failure (n = 11). Ten adults are current nonusers (4.7% of implantees). Reasons include surgical complication necessitating explantation (n = 3), comorbid illness (n = 3), elective nonuse (n = 2), audiologic complication (n = 1), and device failure (n = 1). CONCLUSION: The overall prevalence of device nonuse was noted to increase slowly with time. The role of psychologic factors in contributing to the decision of an individual to elect to opt out of device use remains unproven.

Adolescent↗

Trends and outcomes in the Manchester adult cochlear implant series.

The adult cochlear implant programme in Manchester was established in 1988, initially using funding obtained from the HEAR (Help Ear and Allied Research: charity number: 519784) charity before government resources became available in the mid-1990s. Manchester was the first centre in the UK to implant multichannel devices on a regular basis. To date, over 250 adults have been implanted, including nine bilateral and eight deaf-blind patients. All the patients have a postlingual onset of severe-profound hearing loss; 73% (n = 175) of the implants performed used a Nucleus multichannel implant and 24% (n = 58) used a Medel multichannel implant. In addition, the team has implanted three Medel single channel devices, two Ineraid devices and one Clarion High Focus II device. This study is a retrospective analysis of the trends and outcomes in implant fitting during the first 14 years (1988-2002) of the programme. The paper describes the patient demographics and audiological complications for 240 implantations performed on 214 patients. Speech perception outcomes are reported for a subset of the patients. The average score for the Bench, Kowal, Bamford sentence test at the post-18-month stage of implant use is 66% and for Arthur Boothroyd words 53%. Trends in the series are analysed with respect to the change in criteria for adult implantation, the move towards bilateral implantation and the rate of uptake of cochlear implants by different ethnic groups.

Adolescent↗

Cochlear implantation in the presence of chronic suppurative otitis media.

Nine patients are presented who underwent cochlear implantation in the presence of chronic suppurative otitis media. Four had a simple tympanic membrane perforation, four had a pre-existing mastoid cavity and one had cholesteatoma in the ear chosen for implantation. Patients with a simple perforation had a staged procedure with myringoplasty followed by cochlear implantation after an interval of three months. Patients with cholesteatoma or with an unstable mastoid cavity were also staged. A mastoidectomy or revision mastoidectomy was performed with obliteration of the middle ear and mastoid using a superiorly pedicled temporalis muscle flap and blind sac closure of the external meatal skin. After a further six months a second stage procedure was performed to confirm that the middle-ear cleft was healthy and to insert the implant. Patients presenting with a stable mastoid cavity underwent obliteration of the cavity and implantation of the electrode as a one-staged procedure. To date there have been no serious problems such as graft breakdown, recurrence of disease or implant extrusion, and all patients are performing well.

Child, Preschool↗

An audit of the cochlear implant service in Manchester.

The adult cochlear implant programme in Manchester was established in 1988 and the evaluation of the cochlear implant service involved the first 58 implants users (mean age = 51.65 years, range 19-75 years). Questionnaires were sent to implant users and their partners to evaluate the service with regard to provision of information, clinical care during in-patient assessments, waiting times, operation for cochlear implant and post-operative rehabilitation. The results show that the majority of patients (78 per cent) felt that the implant gave them as much or more benefit than expected. Areas identified for improvements include provision of more written information about cochlear implants; reduction in waiting times for first appointments; more information about the surgical risks and more instruction about home auditory training exercises for family and friends. As a consequence of the audit results the clinical practice and service provision for cochlear implantation in Manchester has been modified.

Adult↗