The ultrasound femur length as a predictor of fetal length.

A linear relationship between the ultrasound fetal femur length and the crown-heel length of the fetus is described. The formula for calculating the fetal length in centimeters was found to be 6.18 + 0.59 x femur length in millimeters. The value and potential uses of the calculated length of the fetus are discussed.

Anthropometry↗

Single ventricle in pregnancy: case report and review of the literature.

A pregnancy complicated by cyanotic heart disease due to single ventricle was recently managed at the authors's institution. Review of the literature showed only five previous case reports. The management of this uncommon disorder is presented along with a review of the literature. The presence of pulmonary hypertension appears to be a major determinant in assessing maternal risk.

Adult↗

The fetal biophysical profile and its predictive value.

Six fetal biophysical variables--the nonstress test, fetal movements, fetal breathing movements, fetal tone, amniotic fluid volume, and placental grading (biophysical profile)--were assessed in 150 high-risk pregnancies during a 30-minute observation period. The predictive value of the nonstress test alone, biophysical scoring, and contraction stress test alone in the identification of the healthy fetus as well as the fetus in jeopardy are discussed. The relationships between individual variables and combinations of variables to the outcome of pregnancy, as reflected by abnormal intrapartum fetal heart rate patterns, meconium during labor, fetal distress, and perinatal mortality rate were determined. The biophysical profile of all hypoxic fetuses was analyzed. These data suggest that the biophysical profile is more accurate in the identification of the hypoxic fetus than any other single method; therefore, a new protocol including the biophysical profile for antepartum fetal evaluation is presented.

Amniotic Fluid↗

Determination of fetal maturity.

A variety of tools are currently available for assessing the various aspects of fetal maturation. Assuring mature neonatal pulmonary function is the goal of maturity testing, and specific test procedures are available to meet this need. The procedures vary from rapid screening tests to very specific phospholipid profiles that incorporate phosphatidylglycerol analysis. One may select from the various procedures those best suited to the clinical needs of a particular patient and the resources of a given institution. Consequently, the inadvertent delivery of a premature infant should no longer occur.

Amniotic Fluid↗

Glucocorticoid therapy for the induction of pulmonary maturity in severely hypertensive gravid women.

Twenty hypertensive gravid women who had their pregnancies terminated for maternal indications because of the severity of pre-eclampsia or chronic hypertension were studied. They were treated at 27 to 33 weeks of gestation with 48 hours of betamethasone therapy prior to delivery. There was one antepartum fetal death, and it is believed that this death was preventable. There was an incidence of respiratory distress syndrome (RDS) of 23% with two neonatal deaths secondary to RDS, for a treated neonatal survival of 85.7%. All losses were from mothers with pre-eclampsia. Pregnancy-related hypertension is not thought to be an absolute contraindication to glucocorticoid therapy for the induction of pulmonary maturity.

Betamethasone↗

The nonstress test.

Antepartum fetal evaluation by heart rate monitoring was carried out on a clinical service during a 1-year period utilizing the nonstress test as the primary screening device. Nonreactive nonstress tests were supplemented by the oxytocin contraction stress test. In this study, the use of the nonstress test appropriately led to the identification of all fetuses who were in jeopardy and, in the majority of instances, identified fetuses in good condition who did not require the administration of oxytocin to determine fetal well-being. In our experience, the nonstress test is a reliable, inexpensive, convenient, time-saving screening procedure which can be made available to a greater number of patients than the contraction stress test alone.

Female↗

Effects of ritodrine hydrochloride on uterine activity and the cardiovascular system in toxemic patients.

The effects of ritodrine hydrochloride were evaluated in 25 toxemic patients in active labor utilizing continuous electronic monitoring of fetal and maternal cardiovascular systems and uterine activity. Fetal scalp blood and free flowing maternal antecubital venous blood was obtained for pH, Po2, Pco2, base deficit and blood glucose determinations prior to and immediately following the study period. The initial ritodrine dose was 50 mug/min for 15 minutes. The dose was increased by 50 mug/min each 15 minutes until there was a clinically apparent reduction in uterine activity. Once this was accomplished, the infusion was maintained for 30 minutes. There was a consistent increase in the maternal heart rate (MHR) and a significant rise in fetal heart rate (FHR) late in the infusion and in the postinfusion period. There was a widening of the maternal pulse pressure mainly due to a reduction in diastolic pressure with little change in the mean blood pressure. Maternal and fetal pH decreased and base deficit increased during the study although the PO2 and PCO2 remained unchanged. Maternal and fetal blood glucose rose significantly following ritodrine infusion.

Blood Glucose↗

Effect of vacuum extraction on umbilical cord blood acid-base measurements.

The objective of this study was to determine whether vacuum extraction is associated with umbilical cord blood acid-base changes when used electively or in the presence of suspected fetal distress. Data from 1,428 patients from a previously published randomized trial of intrapartum electronic fetal heart rate monitoring versus intermittent auscultation were analyzed to identify differences in umbilical cord blood acid-base measurements associated with the elective use of vacuum extraction (patients with duration of second stage of labor 60 min or less) and also in the presence of suspected fetal distress during the second stage of labor. When used electively, vacuum extraction was associated with lower pH (in both umbilical cord artery and vein), lower venous base excess, and higher venous carbon dioxide tension (PCO2), as compared to normal spontaneous vaginal delivery. After correcting for duration of second stage of labor, elective vacuum delivery was significantly associated only with a decrease in cord venous pH and increase in venous PCO2. However, these cord blood acid-base changes were not accompanied by any differences in perinatal morbidity and mortality or in the number of neonates born with acidemia (cord arterial pH < 7.15 or < 7.10). In cases of suspected fetal distress, the use of vacuum extraction was not associated with any detectable cord blood acid-base changes as compared to normal spontaneous vaginal delivery. These data support the continued use of vacuum extraction, especially in cases of suspected fetal distress during the second stage of labor.

Acid-Base Imbalance↗