PubMed Health⌕ Search

Biomedical subjects

D J Oh

Publications and source records attributed to D J Oh.

31 records · Page 2Linked to original sources

Microvascular integrity as a predictor of left ventricular remodeling after acute anterior wall myocardial infarction.

The purpose of this study was to investigate the relation of microvascular integrity and ventricular remodeling after acute myocardial infarction. Twenty-six patients with first acute anterior myocardial infarction were studied before discharge with myocardial contrast echocardiography (MCE). Opacification index (OI) and wall motion index were calculated in the left anterior descending artery territory and left ventricular diastolic volume was measured at baseline and during a 9-month follow-up. In total 26 patients, the regional wall motion improved but the left ventricular volume and global function was not changed significantly at follow-up. When the patients were divided into 3 groups according to opacification index (> or = 0.75, 0.5 approximately 0.75, < or = 0.5) at baseline, functional recovery was not observed and significant left ventricular dilatation was developed in patients with < or = 0.5 OI. Among the baseline echo-parameters such as ejection fraction, wall motion score, left ventricular volume and opacification index, the best predictor for long term left ventricular dilatation was the opacification index by multivariate analysis. In patients with acute anterior wall infarction the assessment of microvascular integrity by MCE at acute stage provides useful information regarding recovery of dysfunctional regional wall motion and ventricular remodeling.

Coronary Vessels↗

Clinical and electrophysiological characteristics in Korean patients with WPW syndrome.

This study was designed to investigate the clinical and electrophysiologic characteristics of WPW syndromes in Korea. A total of 400 symptomatic WPW syndrome patients were consecutively recruited. The most common documented symptomatic tachyarrhythmia was orthodromic atrioventricar reentrant tachycardia (75.3%), followed by atrial fibrillation (31.3%), and antidromic atrioventricular reentrant tachycardia (6.2%). There was a higher incidence of multiple bypass tract in patients with antidromic tachycardia than in those with orthodromic tachycardia (30.4 vs 4.3%, P < 0.001). The inducibility of tachyarrhythmia with electrophysiologic study in this study population was 95.8%. The most frequent location of the accessory pathway was the left free wall (48.0%), followed by the right free wall (29.1%), posterior septum (17.5%) and anterior septum (3.5%). These results indicated that 1) clinical and electrophysiological characteristics of Korean patients with WPW syndrome were similar to those of western countries and 2) the electrophysiologic study was important in the evaluation of patients with WPW syndrome.

Adolescent↗

Coronary stenting (Cordis) without anticoagulation.

We evaluated the effect of antithrombotic regimens on subacute thrombosis and short-term clinical courses after successful implantation of the Cordis coronary stent, which is a flexible, balloon expandable, radiopaque tantalum stent. Two hundred seventy-five consecutive patients with 290 lesions were treated with 356 Cordis stent implantations. According to poststent antithrombotic regimen, patients were divided into 3 groups; 165 patients with 175 lesions received aspirin 200 mg/day, ticlopidine 500 mg/day, and warfarin for 1 month (group 1), 66 patients with 69 lesions received aspirin and ticlopidine (group 2), and 44 patients with 46 lesions received aspirin alone (group 3) after successful Cordis stenting. The overall procedural success rates were 97.7% in group 1, 98.6% in group 2, and 100% in group 3. More than 65% of the patients were eligible for elective stenting. The overall rate of stent thrombosis was 1.8%: 1.2% in patients assigned to the treatment with aspirin, ticlopidine, and warfarin; 0% in patients with aspirin and ticlopidine; and 6.8% in patients assigned to the treatment with aspirin alone. In conclusion, the Cordis coronary stent is an effective endovascular stent in various clinical indications including unstable angina and acute myocardial infarction. Antiplatelet therapy using aspirin and ticlopidine after successful Cordis coronary stenting is a promising alternative to anticoagulation therapy to overcome the drawbacks of stenting. However, poststent antithrombotic therapy with aspirin alone is associated with a significant rate of stent thrombosis.

Anticoagulants↗

Production of monoclonal antibodies against human chorionic gonadotropin by hybridoma cultures in calcium alginate capsules.

A new method of making microcapsules with calcium alginate gel was developed and the cultivation of the encapsulated hybridoma cells producing monoclonal antibodies against human chorionic gonadotropin was investigated. A high cell density of 2.0 x 10(8) cells/cm3 in the capsules led to a high dilution rate of 0.67 per hour and resulted in the high volumetric monoclonal antibody productivity of 652.8 mg/l/day, which was 20-30 times higher than those of traditional continuous suspension cultures. However, long-term continuous culture was not achieved with this capsule system probably because of the limitation in nutrient supply and the accumulation of waste products. Also the analysis of oxygen transfer in this system showed that oxygen supply was not enough to support such a high cell density.

Alginates↗

Intracoronary papaverine but not adenosine reduces regional ventricular function.

OBJECTIVES: Whether intracoronary papaverine or adenosine leads to reductions in regional left ventricular function was tested. METHODS: Fifteen anaesthetised dogs were prepared to record aortic pressure, left ventricular pressure dP/dt, electrocardiogram, regional ventricular shortening, and phasic and mean left circumflex coronary blood flow, and to give intracoronary boluses of papaverine (2, 4, or 6 mg) or adenosine (0.37 and 1.87 mg). RESULTS: Injected doses were chosen to mimic those given in the clinical setting. Papaverine (6 mg) reduced aortic pressure (mean 96(SD 17) to 89(18) mm Hg; p < 0.05), segmental shortening of the infused left circumflex zone (12(5) to 7(9)%; p < 0.05), and area of the pressure-length loop of the infused zone (120(71) to 53(47) mm.mm Hg; p < 0.05). Papaverine increased coronary blood flow (48(25) to 259(95) ml.min-1; p < 0.05), coronary vascular conductance (0.40(0.20) to 2.93(0.94) ml.mm Hg-1.min-1; p < 0.05), heart rate (88(27) to 100(28) beats.min-1; p < 0.05), and the segmental shortening (17(6) to 19(3)% p < 0.05) and area of the pressure-length loop (130(32) to 177(33) mm.mm Hg; p < 0.05) of the non-infused left anterior descending region. The hyperaemia elicited by papaverine was greater than that of reactive hyperaemia (p = 0.008). Papaverine also increased the QT interval corrected for heart rate (0.35(0.04) to 0.45(0.05) s; p < 0.05). When adenosine was given, coronary blood flow and coronary vascular conductance were increased to similar degrees as those during reactive hyperaemia (41(12) to 210(75) ml.min-1 and 0.46(0.14) to 2.43(0.83) mm Hg.ml-1.min-1, respectively; NS). No effects on segmental shortening or the area of the pressure-length loop in either zone were found. Also, adenosine had no effect on the QT interval. CONCLUSIONS: These adverse effects of intracoronary papaverine have important implications in its use in patients, particularly in those in whom abnormal cardiac function already exists. Adenosine, on the other hand, seems to be without deleterious effects.

Adenosine↗

Desensitization of GABA-induced currents in cultured rat hippocampal neurons.

The basic characteristics of desensitization of the GABAA receptor were investigated in cultured rat hippocampal neurons (three days to four weeks in vitro) using whole cell patch clamp techniques. GABA at 10-500 microM was perfused on to neurons for 30 or 60 s, with 60 s intervals of wash with control bath solution between perfusions. Desensitization, evaluated by peak-to-plateau ratio and time constants of current decay (tau), was dose-dependent and culture age-dependent. Desensitization was observed as early as three days in culture, the earliest time tested. At all ages, higher concentrations of GABA induced both larger and faster desensitization. Desensitization was markedly voltage-dependent and decreased with depolarization; peak-to-plateau ratio went from 6.3 to 1.4 and tau went from 4.6 to 26.8 s when holding potentials were changed from -80 mV to +30 mV. Low concentrations of GABA (1-2 microM) perfused for 2-60 s, which did not induce any current, had no effect on the maximal response nor desensitization produced by a subsequent application of 100 microM GABA. This finding suggests that GABA receptors were not desensitized without first being activated.

Animals↗

Comparison of single-photon emission computed tomographic (SPECT) myocardial perfusion imaging with thallium-201 and technetium-99m sestamibi in dogs.

OBJECTIVES: The purpose of the present study was to compare single-photon emission computed tomographic (SPECT) myocardial images of technetium-99m (Tc-99m) sestamibi and thallium-201 (Tl-201) isotopes in the same dog undergoing partial coronary occlusion during pharmacologic vasodilation. BACKGROUND: To date, no controlled study has been reported comparing SPECT Tc-99m sestamibi with SPECT Tl-201 imaging during stress with anatomic and physiologic standards. METHODS: Mongrel dogs were anesthetized with chloralose and instrumented to record left anterior descending coronary blood flow and aortic pressure. Partial coronary occlusion with a hydraulic cuff reduced coronary vascular conductance, which is equal to the coronary blood flow normalized to aortic pressure during peak vasodilation with intravenous adenosine. Each dog received 5 mCi of Tl-201, then 30 mCi of Tc-99m sestamibi during partial coronary occlusion at peak vasodilation. Tomographic myocardial imaging was performed in a 180 degrees anterior arc scan for 33.5 min, first with Tl-201, and later, without moving the dog, for 33.5 min with Tc-99m sestamibi. Postmortem staining defined the region underperfused because of its dependence on the artery that was partially occluded. RESULTS: In seven dogs with moderate reduction in coronary blood flow, coronary vascular conductance decreased with partial coronary occlusion (47 +/- 12%) during Tl-201 imaging and (47 +/- 8%, p = NS) during Tc-99m sestamibi imaging. The underperfused region was 23.9 +/- 6.4% of total left ventricular mass. Counts in the defects were 39% higher (0.86 +/- 0.08 of normal counts) for Tc-99m sestamibi than for Tl-201 (0.64 +/- 0.09 of normal counts, p < 0.001), and the defect on SPECT Tc-99m sestamibi images occupied only a fraction (0.37 +/- 0.30) of the area of the defect on the Tl-201 images of the same dog. Bull's-eye displays constructed from the pathologic slices showed that the Tl-201 defect size was closer to the underperfused region of the left ventricular mass determined pathologically than was the Tc-99m sestamibi defect size. In four additional dogs a severe, near total coronary occlusion was created during Tl-201 and Tc-99m sestamibi administration. In these dogs, similar defect contrast (0.55 +/- 0.12 vs. 0.62 +/- 0.09, p = NS) and areas (0.18 +/- 0.07 vs. 0.18 +/- 0.11, p = NS) were observed with Tl-201 and Tc-99m sestamibi, respectively. CONCLUSIONS: Tomographic myocardial imaging with Tc-99m sestamibi during moderately severe partial coronary occlusion underestimated the area of the defect relative to Tl-201 or to the pathologic reference standard in dogs. Defect contrast was sharper with tomographic myocardial Tl-201 than with tomographic myocardial Tc-99m sestamibi during moderately severe partial coronary occlusion.

Adenosine↗

Sequential recovery of sensitivity to negative and positive contrasts during optic nerve regeneration in goldfish.

A psychophysical procedure, classical conditioning of respiration, was used to measure contrast sensitivity to positive- and negative-contrast discs (8-deg diameter) in goldfish after crushing one optic nerve intraorbitally. In five out of six fish, sensitivity recovered to normal. Recovery times for negative contrasts were significantly shorter than for positive contrasts. The average times postcrush of initial responding to negative and positive contrasts were 23.8 and 30.6 days, and for threshold to come within 0.5 log unit of control values was 29.8 and 39.8 days, respectively. Thereafter, recovery to normal sensitivity was significantly faster for positive contrasts. These results parallel prior observations of neural activity in tectum after optic nerve crush: an early phase of OFF responding followed by a more sudden recovery of ON responding.

Animals↗

Functional properties of retinal ganglion cells during optic nerve regeneration in the goldfish.

After being severed, optic axons in goldfish regenerate and eventually restore the retinotectal map; refinement of the map depends upon impulse activity generated by the ganglion cells. Because little is known about the changes in activity and receptive-field properties of ganglion cells during regeneration, we made extracellular recordings from them in the intact eye up to 95 days after sectioning their axons in the optic tract. Their receptive fields were classified as OFF-, ON-OFF-, or ON-centers, and their axonal conduction velocities measured by antidromic activation. The rate of encountering single units dropped drastically at 4-8 days postsection when only a few OFF-center units could be recorded, recovering to normal between 42 and 63 days. Receptive-field centers were normal in size, except for the few OFF-centers at 4-8 days which were abnormally large. Maintained discharge rates of all types were depressed up to 42 days, but ON-OFF-center units were more spontaneously active than normal around 42 days. Light-evoked responses in OFF-center units were subnormal at 4-8 days, becoming supernormal at 16 days and normal thereafter. ON-OFF- and ON-center units started to regain responsiveness at 16 days, and became supernormal at 42 days, before returning to normal. Conduction velocities of all fiber groups dropped to a minimum at 8 days, the fastest being affected most. There was a gradual recovery to normal conduction velocity by 63 days. The conduction latencies of OFF- and ON-OFF-center units recovered to normal by 42 days, and ON-center units by 63 days. Recovery of ganglion cell responsiveness correlates with functional recovery in the retinotectal system: OFF-center units recover light-evoked responses at about the time OFF activity first reappears in the tectum. ON- and ON-OFF-center units recover later, exhibiting supernormal spiking activity around the time that ON responses reappear in the tectum.

Animals↗

Effect of a gamma-aminobutyric acid uptake inhibitor, NNC-711, on spontaneous postsynaptic currents in cultured rat hippocampal neurons: implications for antiepileptic drug development.

The effect of a novel gamma-aminobutyric acid (GABA) uptake inhibitor, NNC-711, on spontaneous postsynaptic currents was studied in cultured rat hippocampal neurons by the whole cell patch clamp method. NNC-711 decreased the amplitude of inhibitory postsynaptic currents (IPSCs) and did not prolong the decay. NNC-711 also decreased the amplitude of excitatory PSCs (EPSCs). The GABAB receptor antagonist 2-OH saclofen abolished the effect on both IPSCs and EPSCs. NNC-711 itself induced no current and had no effect on currents induced by exogenously applied GABA. These findings suggest that duration of GABAA-receptor mediated IPSCs is not determined by GABA uptake and that GABA uptake inhibitors may work by allowing GABA to remain in the synaptic area long enough to activate presynaptic GABAB receptors.

Animals↗