Development and preliminary clinical tests of an impedance sensing VDD recording pacemaker for diagnosis and research.

Episodes of serious but infrequently occurring cardiac arrhythmias can be difficult to detect and analyse, even with modern Holter monitoring. A previous diagnostic pacemaker developed by this group provided VVI pacing therapy and recorded intracardiac ECG signals but had no atrial sensing or impedance measuring capability. A new external diagnostic pacemaker system is described that has been developed to assist in diagnosing intermittent arrhythmias by selectively recording intracardiac signals. Unlike other ambulatory monitors, in addition to recording ECG, the device combines VDD pacing therapy with the capability of monitoring and recording intracardiac impedance and pressure waveforms through a temporary intracardiac lead. A PCMCIA memory card allows storage of 48 arrhythmic events of 21 seconds each. Twelve seconds of waveform are retained before the event occurs and nine seconds after. Data retrieval and processing is performed with a PC which reconstructs each waveform for display. The ECG provides data on cardiac rhythm while cardiac function is inferred from the haemodynamic signals. During simulated trials, 14 event types were presented to the system. All events were successfully detected and recorded. During in vivo clinical tests 83 waveform recordings were made. Impedance fluctuations with typical peak-to-peak values of 64 ohms were successfully recorded.

Arrhythmias, Cardiac↗

Clinical trials of a dual-sensor diagnostic pacemaker.

The results of clinical trials of a dual-sensor diagnostic pacemaker are described. The system monitors and records intraventricular electrical and pressure waveforms using a special lead incorporating bipolar electrodes together with a piezoelectric pressure transducer. The recorded waveforms, which are shown in conjunction with Holter recordings made simultaneously, demonstrate the value of pressure measurements and illustrate several cardiac events, including an ECG pause, bradycardia, a pressure pause, ectopic beats and tachycardia. The pacing function of the device is shown and capture is demonstrated.

Arrhythmias, Cardiac↗

A dual-sensor diagnostic pacemaker for ambulatory cardiac monitoring.

Unexplained blackouts are a very common medical problem. Some patients presenting themselves at hospital with such symptoms have underlying bradycardia or extreme tachycardia with a profound decrease in cardiac output. Modern treatment of these patients may be highly effective but accurate diagnosis of their exact condition may be needed. A novel ambulatory dual-sensor diagnostic pacemaker has been developed to meet this requirement. The device monitors intracardiac ECG and intraventricular pressure through a special lead introduced perveneously into the right ventricle and detects and counts events such as bradycardia, tachycardia, pauses in the electrical or pressure signals and electrical interference. Analogue recordings of the electrical and pressure waveforms of 16 of these events can be made during the operating period of 3 weeks and pacing is incorporated via a specially-adapted commercial pacemaker if a prolonged episode of bradycardia or a pause is sensed. The device forms part of a complete diagnostic system also incorporating a computer which is used to set up the parameters of the diagnostic pacemaker and to display and analyse the recorded data.

Diagnosis, Computer-Assisted↗

Single lead atrial synchronised pacing in patients with cardiogenic shock after acute myocardial infarction.

A pacing system requiring only a single lead was used to establish atrial synchronised pacing in eight patients with complete atrioventricular block and cardiogenic shock following acute myocardial infarction. Spontaneous atrial activity was sensed through electrodes positioned on the pacing lead and used to trigger ventricular demand pacing. A normal atrioventricular relation could be established in each of these critically ill patients without the complexity of inserting and finding a stable position for an additional atrial sensing lead. Atrial synchronised pacing at the spontaneous sinus rate had distinct haemodynamic advantages compared with conventional ventricular pacing at 100 beats/min. Mean cardiac output for the group was 3.3 1/min with atrial synchronised pacing compared with 2.6 1/min with conventional pacing, a significant difference of 27%. Peak systolic pressure averaged respectively 91 and 73 mm Hg in the two pacing modes. With conventional ventricular pacing a pronounced phasic alteration in blood pressure was observed, dependent on the altering relation of the paced beats to spontaneous atrial activity. Atrial synchronised pacing abolished this effect and resulted in a stable blood pressure at or above the peak pressure achieved with conventional pacing. Atrial synchronised pacing with a single lead system can be established rapidly. This mode of pacing has appreciable and significant haemodynamic superiority over conventional ventricular pacing in patients with cardiogenic shock and atrioventricular block following acute myocardial infarction.

Aged↗

A flexible signal-averaging system for cardiac waveforms.

The repetitive nature of cardiac waveforms renders them suitable for processing by signal averaging. A flexible system is described, based on a general-purpose digital computer, capable of averaging a variety of cardiac signals in excess of 0.5 microV containing frequency components below a theoretical Nyquist limit of 5 kHz. Important features of the system include real-time processing capability at a high level of interactive control, and the facility to trigger the averaging process accurately from any part of either the data or a synchronous reference waveform. Application of the system to electrocardiographic and phonocardiographic signals at conventional gain has enabled clinically useful records to be obtained in the face of obtrusive environmental noise. The averaging of signals of a similar nature after considerably increased amplification has revealed cardiac activity unseen in conventional records in a total of 81 subjects.

Analog-Digital Conversion↗

Low voltage electrical activity preceding right atrial depolarisation in man.

Electrical recordings were made in the high right atrium in 28 patients undergoing cardiac catheterisation and in 3 healthy volunteers. After filtering and amplification by 3 to 10 million times, the signals were passed through a signal averaging process in a digital computer. Of the 28 subjects who had technically satisfactory recordings, 23 showed low voltage electrical activity preceding the conventionally-recorded atrial depolarisation. The low voltage activity started 50 to 200 ms before the atrial deflection and was variable in shape. These early signals may be the result of activity in the region of the sinus node.

Arrhythmia, Sinus↗